ScottW514 cd8a01a3d9 bench: every board-runnable tool ported to the bench page
The remaining bench diagnostics run from forgetest's #bench tab. The
tools that also run from a LAN host share scripts/bench/gfbench.py:
GF_HOST names a remote machine (host mode, sysfs through ssh, Grbl and
forgectrl over the LAN); unset, the tool runs on the board itself
(local mode, sysfs directly, everything on 127.0.0.1), which is how the
page runs them - with GF_HOST=127.0.0.1, the panel token in GF_TOKEN
and their data files under <data>/bench/ (FORGETEST_BENCH_DATA). The
helper also reads a machine setting from forgectrl, or from the settings
file on the board while forgectrl is stopped.

Ported: pwm_sweep / pwm_hold (scope = a takeover; the latch relocked,
the write refused if FIRE or LASER_ON reads active), pwm_stream_test
(PASS/FAIL exit), flow_characterize, flow_recheck_char,
flow_warm_validate and flow_matrix (takeovers: forgectrl owns the
thermal hardware, so the page's takeover replaces the tools' own
controller stop/restart, whose command line predated the supervisor;
results and logs in the bench data directory), flow_sustained,
fan_test, temp_calibrate (dry; watch bounded in seconds; the threshold
and the coolant conversion from the shared code), flow_escalate_drill
(cool_confirm_max_s shortened through forgectrl's settings for the
drill and restored; the setting's minimum is the default budget), and
live_fire_drills (<drill> [S] [F], all six drills, host from GF_HOST,
token from the board). flow_matrix joins the registry. What stays
unported cannot run against the machine at all: the two null-sink CI
harnesses and the .puls decoder.

Runner: a scope tool runs inside the takeover wrapper; the bench
environment above is passed to every tool. Tests: test_bench_registry
(registry <-> scripts/bench consistency, every ported tool builds its
command line, every script compiles, gfbench host/local modes) and the
server test (scope tool takeover, the environment reaching the tool).
Local mode smoke-run on the bench (temp_calibrate watch, setting, token)
from /tmp, removed after.

No catalog consequence: bench tools are not image components (dev-only
forgetest); the acceptance catalog is unchanged.
2026-08-16 16:28:39 -04:00
ScottW514 af3a693c0b bench+docs: flow suspicion drills, coolant-flow triage record
flow_confirm_drill.py walks the driver's suspicion/confirmation state
machine through every verdict with real pump-off transients in one M8
session; flow_escalate_drill.py exercises the starved-re-check
escalation against a short GFCOOL_CONFIRM_MAX_S. BRINGUP records the
triage resolution (the 2026-08-03 faults were a real transient
stagnation, probable pump airlock - the check was right), the slug/
circulation measurements, and the new check semantics.
2026-08-08 10:59:47 -04:00