The catalog follows forgectrl's setup (openglow-org/forgefirm#4): the
gate is the advisories with the press, the account, the required steps
(preferences, machine, cloud), and the intake fan count; every other
step is recommended; the setup sheet is retired for two self-contained
burns and a dark lens travel check; the override file is gone.
- setup.gate-blocks-controllers installs four records: without consent,
without the account, and without the three required steps the
controller is gated with the reason naming the cause; with them done
the gate opens, the controller runs, and the other steps are
recommended as not run. Clearing cool_intake_fans closes the gate live
with its reason, and putting it back as found reopens it.
- setup.override-until-reboot is deleted with its helpers, and
forgetest.init no longer writes the override file at boot.
- setup.first-run-flow follows the reason from the three required steps
to open; setup.first-run-page walks the choice screen after them;
setup.what-changed reads the one-level map with the gate unmoved.
- New setup.check-intakes (the count by the tachs equals the machine's,
the setting put back as found) and setup.check-lens (the window
written equals the stops found or the fallback, and the settings and
/status hold it; both keys restored). A precheck refuses the intake
and airflow checks while cool_intake_fans is unset, so neither can
leave it unset in the middle of a campaign.
- setup_burns.py replaces setup_sheet.py: setup.focus and setup.floor
answer the gantry stops, the home, the scrap and the thickness, and
keep the preview, emission and window checks; motion.tray starts the
focus burn for its tray-out refusal.
Proof: the forgetest host suite (529 before the required-steps edits,
and the full suite after them) and the manifest load pass; pyflakes
reports no undefined names. The coverage lint is clean against
forgectrl's working tree; against the current pin, setup.check-lens's
src/lensfind.* glob selects no file until the forgectrl pin moves to the
commit that adds it.
Acceptance: these are the tests themselves; the campaign runs them with
cool_intake_fans set on the bench.
forgectrl c274f19 adds cool_intake_fans: at 1, a machine built with one
intake fan, the second intake is published not fitted and never judged,
and the setup's airflow check writes the count it finds.
cooling.intake-one-fan, in a suite module of its own, proves both halves
on a machine with two intake fans with the setting alone. With
cool_intake_fans 1 and an 8 s grace, a session at the cut fan profile
must publish intake_2 as not fitted with no floor while it reads a real
speed, run OK, and judge intake_1 ok at the intake floor; with the intake
floor at its legal maximum it must trip AIRFLOW (hold, fire blocked) with
intake_1 TRIPPED and intake_2 still not fitted, and the fault must end
with the session; restored, every fan reads ok at its floor. It starts
only from a machine with both intakes judged, requires
cooling.fan-gate-trips, and puts the count, the intake floor and the
grace back as found on every exit path.
setup.check-airflow now reads the count from the result: 2 needs all
four fans at least 1000 rpm, 1 needs intake 2 reported {"fitted": false}
and the other three ok; either way the setting must read what the check
found, and the count is put back with the five floors.
Fingerprints: the new test has a module of its own, so no cooling test
moves; the setup.check-airflow edit is inside its function. Diffed across
the change: 127 -> 128 tests, one added, setup.check-airflow the only
one moved.
Proof: the touched host tests pass (test_cooling_intake_suite 4,
test_setup_dark 10, test_cooling_suite 25) and pyflakes is clean.
test_cooling_intake_suite replays the test against a scripted engine,
and two broken engines fail it with the settings put back: one that
ignores the setting, and one that takes intake 1 out with intake 2.
test_setup_dark's new AirflowCheckTests take a two-fan and a one-fan
result, and fail a count the setting does not match and a result with
no count. On the bench reference, image 20260928194539 (dev) with these
files and forgectrl c274f19 bind-mounted, cooling.fan-gate-trips,
cooling.intake-one-fan and setup.check-airflow pass with a clean
baseline before and after each (forgectrl's commit has the readings).
The commission.* tests are setup.* (subsystem "setup"): suite/setup.py,
setup_dark.py, setup_sheet.py, and the host tests test_setup_*.py. The
coverage maps name src/setup.* in place of src/commission.*, the record
is setup.json, and the bench seed in forgetest.init creates
/run/forgefirm/setup-override.
setup.check-sensors follows the check as it is now: no question is
asked and no setting is written. The test reads the settings before
and after and fails on any change, and fails at once if the check
opens a prompt. The host test drives the fake daemon with no prompt
and proves both outcomes.
Proof: test_setup_dark.py, test_setup_sheet.py, and
test_setup_suite.py pass (46 tests). The coverage lint names
src/commission.c and .h as uncovered until the forgectrl pin moves to
the revision that carries the rename.