- platform_drills.py (on the board, forgectrl stopped): dead-man trip
readback, rmmod/modprobe with concurrent attr reads, decay/microstep
readback, LED sequence.
- live_fire_drills.py: ircut (S/F selectable characterization job),
expstop (armed job + POST /controller/stop, controller left stopped),
ctrlstart (separate, operator-approved resume); the token header is sent
in exact case.
- laser_lifecycle_test.py: sigterm-mid-job - SIGTERM during an armed job
must stop it, relock the latch and exit promptly.
Phase 5 A-1 emission witness and A-5 HV telemetry pass on live burns;
A-2 lid-IR characterized as a weak signal at 40% (gate left watch-only);
pgood confirmed unusable as a witness on this PSU. Phase 4 X-3 (0.1s
job-based disarm on M2) and G-10 (disarm counts down in Hold) pass.
Adds live_fire_drills.py (arm-lifecycle sampler over TCP + HTTP).