ScottW514 adcd1adb9a Fan floors from the measurement; a hunt is measured, not judged
forgectrl pin 47e4256: the airflow floors set from the bench measurement
(exhaust 6400, intake 2290, air assist 6000 rpm, purge current 300, grace
15 s) and the operating-point rule: a fan is judged while the laser is
armed, when a job's profile may raise it but never lower it below the run
duty, or whenever it is commanded at the run duty; the service's hunts,
sent with the extraction fans off, are measured and published unjudged.

Catalog: cloud.mode-switch now waits out the connect-time hunt sampling
/cool/status and requires no AIRFLOW, the exhaust row unjudged and the
exhaust actually off; its covers gain forgectrl src/cool.* and
src/airflow.*. cooling.fan-gate-trips uses an 8 s test grace (the
intakes take 7 s to 90 percent and tripped under the old 2 s at the new
floor) and its off leg waits for the row state as well as gates_off.
fan_floor_measure.py names a reply that is not JSON and calls the purge
readings idle and run (the pump is always on).

Docs: COOLING 3a and the settings table, BRINGUP item 19 and a facts-bank
entry with the measured fan speeds, the bench README, and a CAMPAIGN-LOG
entry for the measurement, the two status-document finds, the hunt find
and the hot-deployed bench runs of both tests.
2026-08-22 09:56:53 -04:00
ScottW514 a8a02596cd Bench: fan_floor_measure.py, the numbers the airflow gates ship with
Two modes. spinup opens a run session with M8 from the engine's idle
posture, samples the four tachometers and the purge-air current once a
second, ends the session with M9 and waits for the engine to leave run;
per fan it reports the steady speed at run duty, the time to 90 percent
of it and the spread over the steady window, the purge current off and
on, and candidate floors at 55 percent of steady. cut sends nothing and
samples while the operator runs a real cut, for the spread the debounce
has to ride over under the only load that matters. Registered on the
bench page as fan-floor. Tooling only; no catalog consequence.
2026-08-21 18:44:07 -04:00