Author SHA1 Message Date
ScottW514 6458f6aec0 The ceiling at its off end stands with the default critical line
forgectrl pin 368fd0c: the critical-line cross-check binds only while the
ceiling is a gate. cooling.critical-tier pins that a POST setting the
ceiling to its off end is accepted with the default line (the unit fake
mirrors the exemption); CAMPAIGN-LOG records the gate-off failure on dev
image 20260822165832 that found it, and the critical-tier pass.
2026-08-22 13:43:36 -04:00
ScottW514 9fae47cf14 The critical tier proven on a rising loop; the board temperatures watched
forgectrl pin 76115fd: the chassis LM75 and the supply sensor ride /status
as temps (degrees and a raw count), the engine ranges them over every run
session into one run-end line, and a critical fault that clears with its
session yields the reason to the standing hold.

Bench: critical_tier_drill.py (a bench tool now, registered as
critical-tier) sets the ceiling, the resume gate and the critical line a
few tenths above the live upstream reading and lets the engine's own
flow-check heater warm the loop through them inside one M8 session;
temp_calibrate.py gains supply-watch, supply-point and supply-fit for the
supply sensor against a thermometer on its heatsink, the fit shown beside
UAPI.md's unverified guess.

Catalog: cooling.gate-off checks the /status temps fields and the run-end
board-temperature line (the unit fake mirrors both, one new failure
case); cooling.critical-tier checks the reason after a faulted session.

Docs: CAMPAIGN-LOG entries for cooling.critical-tier on dev image
20260822154257 and the warm-loop drill (OVERTEMP at 10 s, CRITICAL at
14 s, the fault ending with the session); BRINGUP item 19, the facts bank
(board temperatures at idle), COOLING section 9, the bench README.
2026-08-22 12:56:40 -04:00
ScottW514 f51140e528 The coolant critical tier, with its catalog test
forgectrl pin a1875a8: cool_temp_critical_c (default 38 C) is the fail
tier above the coolant ceiling's pause: at or over it in a run session the
verdict is CRITICAL (fire blocked, hold, no resume this job), the fault
ends with the session, the settings API keeps it above the ceiling, and
its top turns the gate off.

Catalog: cooling.critical-tier (auto, 45 tests), driven through the
settings API like cooling.gate-off: a critical line at the ceiling is
refused (and undone should it ever be accepted); with the ceiling, the
resume gate and the critical line all under the coolant's temperature a
session reads CRITICAL rather than OVERTEMP with no resume and the reason
naming the tier and the coolant; after the session the ceiling alone
holds (OVERTEMP); with the critical line at its top the gate is off
(gates_off, the run-start log line) and the ceiling alone pauses;
restored, OK with nothing off. Four unit cases against a scripted engine.
_after_session takes the condition to wait for.

Docs: COOLING (verdict table, section 5, the settings table, the quick
reference), BRINGUP item 19 and the catalog count, the CAMPAIGN-LOG
paragraph for the fan-fault session rule on dev image 20260822145201.
2026-08-22 11:41:18 -04:00
ScottW514 c1591e4f69 The fan floors proven on a pinned image; a fan fault ends with its session
The dated record of dev image 20260822135848: the campaign of every
non-operator, non-live test at 18 of 18 PASS with the measured floors and
the operating-point rule (cooling.fan-gate-trips and the hunt leg of
cloud.mode-switch as recorded), and the unplugged-exhaust-fan drill:
AIRFLOW at the grace plus three ticks with the exhaust dead, the other
fans held, the reason relayed on the Grbl port, the replugged fan ok
inside the next session's grace.

The drill showed the fault riding into idle, where the hold canceled
jogs and would have refused the cloud print that re-proves the fan.
forgectrl pin d51dbdb: the fault ends with its run session, and the next
session judges every fan afresh. cooling.fan-gate-trips checks the
verdict is OK with no hold once the tripped session is over (the unit
fake mirrors it); its covers, and the cooling tests' shared covers, gain
src/coolfmt.* (the tree manifest carries the new files at the bumped pin,
and the lint was right to ask). cloud.mode-switch samples the hunt's gate
rows twice a second: a hunt's run phase is a few seconds long.

Docs: COOLING 3a, BRINGUP item 19, CAMPAIGN-LOG.
2026-08-22 10:46:41 -04:00
ScottW514 adcd1adb9a Fan floors from the measurement; a hunt is measured, not judged
forgectrl pin 47e4256: the airflow floors set from the bench measurement
(exhaust 6400, intake 2290, air assist 6000 rpm, purge current 300, grace
15 s) and the operating-point rule: a fan is judged while the laser is
armed, when a job's profile may raise it but never lower it below the run
duty, or whenever it is commanded at the run duty; the service's hunts,
sent with the extraction fans off, are measured and published unjudged.

Catalog: cloud.mode-switch now waits out the connect-time hunt sampling
/cool/status and requires no AIRFLOW, the exhaust row unjudged and the
exhaust actually off; its covers gain forgectrl src/cool.* and
src/airflow.*. cooling.fan-gate-trips uses an 8 s test grace (the
intakes take 7 s to 90 percent and tripped under the old 2 s at the new
floor) and its off leg waits for the row state as well as gates_off.
fan_floor_measure.py names a reply that is not JSON and calls the purge
readings idle and run (the pump is always on).

Docs: COOLING 3a and the settings table, BRINGUP item 19 and a facts-bank
entry with the measured fan speeds, the bench README, and a CAMPAIGN-LOG
entry for the measurement, the two status-document finds, the hunt find
and the hot-deployed bench runs of both tests.
2026-08-22 09:56:53 -04:00
ScottW514 0bddc9eeab cooling.fan-gate-trips: a fan under its floor is a fault; pin the airflow gates
The acceptance catalog gains the test behind forgectrl 5a31d66: an
exhaust floor at the legal maximum must trip AIRFLOW after the grace and
three ticks (hold, fire blocked, no resume, the exhaust gate TRIPPED and
named in the reason); a purge current floor at the ADC rail must trip
the same way; an exhaust floor of zero must read off in gates_off and
trip nothing; restored, the next session must run OK with every fan at
or above its floor. Three host cases against a scripted engine that
models the grace and the readings. The covers map names src/airflow.*.

COOLING.md gains 3a (the airflow gates) and the five settings with their
ranges and bands; SERVICES.md the gate rule, the rows, the AIRFLOW
verdict and fan_gates; SAFETY.md names the floors among the verdict's
inputs; BRINGUP item 19 records the gates as in with provisional floors
and the catalog at 44. Pins: forgectrl 5a31d66, forgefirm-app 81027ff
(0.1.15+git); fetch-verified.
2026-08-21 19:00:06 -04:00
ScottW514 d530f773e2 cloud.pause-resume reads the job's limits through; pin the pass-through
The pulse header's envelope now reaches the cooling engine: the cloud
client (python3-gfhardware c34faa1) derives the coolant window and the
fans' minimum speeds from the header and rides them on every report,
and the engine (forgectrl 57f6064) resolves each as the stricter of its
setting and the job's, never looser and never overruling an off gate.
cloud.pause-resume, which runs a real print, now also reads the client's
"job limits from the header:" line and the engine's "effective limits:"
line from the two logs; two host cases cover the failure paths. The
needle guard lists the engine's phrases as not the app's.

COOLING.md section 2 explains what a cloud job brings with it; BRINGUP
item 19 records the pass-through as landed. Pins: forgectrl 57f6064,
forgefirm-app c34faa1 (0.1.14+git); fetch-verified.
2026-08-21 18:07:41 -04:00
ScottW514 bf3483e994 cooling.gate-off: a gate setting trips in range and is off at its far end
The acceptance catalog gains the test behind forgectrl 9e44fdc: the
coolant ceiling set just over its legal minimum must trip OVERTEMP with
a hold and fire blocked at the next run start; set to its top the engine
must skip the gate (verdict OK), report it in gates_off on /status and
/cool/status, and log the run-start line; the original values are
restored, on failure too, and proven restored. Five host cases against a
scripted engine. The cooling covers map now names the files that carry
gate state (gates, settings, status, the panel) and corrects a glob that
matched nothing: the GRBL cooling client is src/glowforge_cooling.c, not
src/gfcool*. The fake forgectrl serves /logs/tail and keeps blank form
values as "clear", which is what the daemon does with them.

Docs: COOLING.md section 8 carries each setting's legal range and
recommended band and a new 8a on turning a gate off; SAFETY.md names
what no setting can reach; ACCEPTANCE.md records that gates are
exercised through the settings API, never GFCOOL_* env overrides;
BRINGUP item 19 records the pattern as landed and the catalog is 43.

forgectrl pin moves to 9e44fdc; fetch-verified.
2026-08-21 17:06:49 -04:00
ScottW514 5a587c3536 Name the verdict, not the report, in the stale-verdict rule
The section describes two channels flowing opposite ways - the
controller's job-state reports and the engine's verdict - so "the report"
pointed at the wrong one directly under a lead that names the verdict.
2026-08-18 07:43:16 -04:00
ScottW514 7012c7d1b2 Homing is lid-gated in practice; only the cloud hunt is not
MOTION said jogs, homing and hunts were all ungated. Jogs are:
gfsw_visible withholds the door signal while the core is idle, jogging or
homing, so a jog both starts and runs with the lid open. Homing is not.
With homing_mode = gfcloud - the only method that works today - $H hands
the cycle to a cloud homing session, and its move to the home corner is
an ordinary motion action taking the default lid_gated=True: refused with
the lid open, stopped on a lid edge mid-run. Only the lens/Z hunt inside
that session passes lid_gated=False, and that session is also the only
place a hunt happens in GRBL mode - there is no hunt outside one.

BRINGUP gains item 18: GRBL pause and resume should leave no gap in the
cut, the way the factory's does. The beam stops at the start of the hold
(disable_laser_during_hold, on by default), so the head travels the whole
deceleration dark and the resume restarts from a standstill where the
decel ended - an unburned length, then a dwell through the accel that M3
shows as a deeper spot. The kernel waypoint backtrack cloud mode uses is
refused with EPERM on a live-streamed ring, so the equivalent has to be
built above the ring, where grblHAL still holds the planned path the
kernel has already overwritten.

Two wording fixes: the cooling verdict is described as a report rather
than a file, and gfcloud homing as using the machine's builtin
credentials.

Documentation only - no behavior change, so no acceptance-catalog
consequence.
2026-08-18 07:41:37 -04:00
ScottW514 d3bab940b3 docs: user-facing guides to motion, laser drive and cooling
Two pages aimed at someone who owns the machine rather than works on it,
written for the documentation site. Nothing here is new behavior - it is
the behavior the machine already has, explained where an owner can find
it instead of spread across a kernel contract, a services contract and
three driver headers.

MOTION.md follows one thread: everything physical comes out of a single
fixed-tick byte stream, so the page starts there - the byte layout, speed
as step density rather than clock, the ring and the two ways to fill it,
and the hardware's own stop, halt and resume-with-waypoint. The laser is
presented as part of that stream rather than beside it, which is what
makes the three contract rules (power before fire, no consecutive power
bytes, end dark) and the persisting duty legible instead of arbitrary.
Then geometry and limits, device ownership and the liveness check the
operator sees, and the two modes in full: GRBL from connection through
the arming sequence, the stop/pause/fault table and homing-or-not; cloud
from the preloaded pulse file through the pause backtrack, the park that
ignores the lid, and the ring's cap on job length. A comparison table and
the motion-related settings close it.

COOLING.md explains the engine as what it is - one owner of the thermal
hardware answering a single question for whichever controller runs - and
gives the reasons behind the numbers rather than just the numbers: why
the flow check heats and measures the downstream rise, why 40 percent is
the duty (below it, convection mimics flow), why the settle gate uses a
split-half mean instead of peak-to-peak, and why one bad reading is a
suspicion rather than a fault. Over-temperature, the two diagnostics
tools and when to run them, the settings, and a situation-to-response
table. The fire watch is described honestly: the lid IR channels are
first of all a photometer for the lid lamp, the gate ships watch-only,
and it is not a fire alarm.

Both pages state what is not implemented - low-temperature gates, TEC
control, a fire watch that acts, limit-switch homing - so nobody plans
around them. Constants come from the sources that own them (the feeder
contract, cool.h, the board header, the services contract), not from
prose. README links both.

Documentation only, no behavior change and no catalog consequence: docs/
is outside every layer and .md is excluded from the layer content hash.
2026-08-17 11:52:41 -04:00