5
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
b2a011ac08 |
ctlport_test: the polling sender is a Grbl sender, not a product
The NewlinePoller docstring and poll_case's named one sender product as the sender that polls '?' with an end of line behind it, and quoted that product's poll rate beside the harness's own. The behavior under test is the controller port's: an empty line is not the sender speaking, a port jog is never refused for a poll, and every poll draws its one ok. Which sender polls, and how often, is not the contract; the harness's own rate (four times a second, period 0.25) is the fact that matters. Both docstrings now say a Grbl sender that polls, and the comparative rate is gone. Proof: docstrings only, no behavior change. python3 -B -m py_compile and pyflakes are clean on scripts/bench/ctlport_test.py, and the file names no product. The harness runs in grblHAL-glowforge CI (python3 forgefirm/scripts/bench/ctlport_test.py build/grblHAL_glowforge). Acceptance: none; docstrings of a harness outside every covers map. |
||
|
|
8e1fe5090d |
Harnesses: the null-sink cases other tests prove leave
The grblHAL harnesses keep what only a running controller shows; the cases a host unit test in grblHAL-glowforge proves, and the log and reply wording, leave. - laser_lifecycle_test: test_arm_waits_for_the_fans goes. laser_arm_test case A4 (grblHAL-glowforge) proves the fan grace stretching the arm's acknowledgment budget, on the same arm path. The docstring names it. - xy_mode_test: case_x32, case_invalid and the log checks go; the default, x16 and the low tick stay. xy_scale_test holds each mode's tick and the not-a-mode parse. - planner_blocks_test: one restart, at $398 1000; the 400 pass and the fresh-store probe go. - ctlport_test: test_poll_lf and test_crlf go (the CR LF poll stays); in test_sender_out the network turn-away goes (serial_test holds it), and the busy gating, the grant and the outlives-client part stay. test_port_dark is whole. - mcode_test: the timeout case runs on the host build's 5 s GFMCODE_WAIT_S (grblHAL-glowforge's CI configures it; the image keeps 30 s) and still shows the hold, at 5.1 s; 5 s outlasts the 3 s test_dark watches the wait; test_table refuses one form per parser branch. test_timeout_holds and test_dark stay. - envelope_test: test_unset and test_bounds go (lens_home_test holds the clamp); test_armed and the open, apply and close cases stay. - manual_home_test: the out-of-range offset block goes, a repeat of gfhome_clamp_home_mm (lens_home_test); the modal-M3 FIRE check and every release and energize case stay. - cool_report_test: one non-hex secret and one CR LF injection stay; runner-malformed and the exact header-set checks go. A bad secret is never sent and a good one is. - tray_test: test_offset keeps 20 mm; test_errors keeps a bad P and a bad axis; the frame shift, envelope, barrier, persistence, port op, unreferenced lens and camera home stay. Proof: with grblHAL-glowforge's matching commit, the eleven harnesses its CI runs pass under Linux against the null-sink build: nine on a build with a 1 s M-code wait, and mcode_test and tray_test, the two that wait at an M-code, on the 5 s build CI configures (-DGFMCODE_WAIT_S=5.0). pyflakes reports nothing in the nine changed files. Push this before grblHAL-glowforge's commit. Acceptance: none; host harnesses only. |
||
|
|
cd84786fc5 |
tray_test.py and motion.tray: the crumb tray's mode on the null-sink controller and on the machine
- scripts/bench/tray_test.py, run by the driver's CI: M103 P1 and P0 move Z and its envelope by tray_offset_mm on the lens step grid, tell the sender, write and remove the marker beside the shared config, and ship no step; a missing P, P2, P0.5, P-1, and an axis word are errors that change nothing; the switch behind a move waits for the move; the port's tray op with a sender connected, its count exact, refused out of form, during a program, and at a package's M-code; the mode across a soft reset and a killed controller, a start over the marker taking the lens reference in the tray-out frame; the offset's range; an unreferenced lens; a camera home in both modes handing the runner the same park. The kernel-idle half of the barrier needs the pulse device: a null sink is always idle. - scripts/bench/ctlport_test.py: the dark case carries tray out and in under an open armed window. - forgetest: motion.tray in its own module, suite/tray.py, so no other test's fingerprint moves. It switches the mode both ways through the panel's route and through M103 from a Grbl client and judges each switch: /status's mode, Z, and reach moved by the offset's grid, the port's state, the marker, the reference and its source unchanged, the client told, the kernel's counters unmoved. A jog to the Z the lens read before a switch is refused in the other mode and taken back in the mode found; a setup card started with the tray out is refused in the operator's words; the panel page carries the switch. The mode goes back as found in a finally. It does not restart the controller, which would drop the X and Y reference: persistence is tray_test.py's. - The bench registry and README list tray_test.py. Proof: tray_test.py ALL PASS against the driver with the mode, and six driver copies each missing one part of it fail. The driver's whole CI harness list passes. The forgetest unit suite: 500 tests OK. The coverage lint over the working trees: nothing uncovered, 126 tests. On the bench reference, with the binaries hot-deployed on the fx18 image: motion.tray PASS, and FAIL against the driver whose anchor lost its source word on the second switch. Acceptance. motion.tray is new; the suite and bench files are in no other test's fingerprint. |
||
|
|
6e71ac86f0 |
forgetest: exthost.sender-keep-out, camera.lid-privacy for local viewers, and ctlport_test's keep-out
- suite/extsender.py (new module, so no other test's fingerprint moves): exthost.sender-keep-out. A reference package whose service claims the Grbl sender out as it starts, installed with the sender.keep_out grant (and refused without it), on an idle GRBL-mode machine with no sender connected. It checks the holder and the ext: lease of the extension kind, the host's claim file fresh past forgectrl's grace, a sender from the machine's LAN address turned away with the message and one from the loopback admitted, the operator's release (lease gone, network welcomed, the package reading released), a new claim after a restart, and the stale end with the notice after a disable; everything is put back as found. - camera.lid-privacy: the head camera answers the panel's token and the extension host's header with the lid open, and refuses the cloud client's form (no token, no header) and a stream for no local viewer; the lid camera stays refused to everyone. covers gains src/auth.*. - scripts/bench/ctlport_test.py: test_sender_out on the null-sink controller build (Sender(host=) and closed, own_address(), generation()). Proof: forgetest's unit tests pass; the coverage lint passes against the working trees' file lists. Against the current pins it reports src/senderout.* as selecting nothing until forgectrl's pin moves to the revision that adds it, which lands with this. On the bench reference with the suite mounted: exthost.sender-keep-out PASS (first run found the check racing the host's first write; the test now waits for the file and holds past the grace), and camera.lid-privacy passed every check of its body (its hand-back failed only on the controller gated by the privacy advisory's Revision 5 before it was accepted). ctlport_test.py passes in the driver's CI. |
||
|
|
b29bb9e023 |
bench: the controller port and manual home harnesses
Two host harnesses for the grblHAL driver's null-sink build, in the bench
registry and the README with the others. The driver's CI runs them.
ctlport_test.py drives the controller port beside a scripted Grbl sender
that counts every ok and error it is sent, which is the only way to see a
status routed to the wrong source. 13 cases: the socket's mode; a port
jog's status going to the port with the sender's count exact and the jog
run whole under the sender's '?' polls; a port error the sender's next line
does not inherit; the sender's line canceling a fast port jog and drawing
its own ok (fast on purpose: a slow jog stops at once and would pass with no
hold at all); a sender line queued right behind the port's; the refusals;
one client, and five reconnects right after a close; the status hook across
a soft reset; the dead-man; a CR LF sender; a sender that polls the way
LightBurn does, '?' with an end of line behind it, LF and CR LF (every port
jog accepted, a 60 mm port jog run whole with the polls landing inside it,
one ok per poll, a real line still canceling a port jog); and every
operation of both sets under an open armed window with M3 modal and S500,
where the dump must hold no FIRE tick.
manual_home_test.py reads the stream dump (GFSINK_DUMP) and the attribute
log (GFSINK_ATTR_LOG), so it can say that nothing was shipped and which
current was written, and how many times. 9 cases: a manual $H ships no step
and no FIRE tick and declares the offsets with the soft limits on and Z
kept; $H refused in a cycle; $MD refused under an open armed window with
nothing written; every motion source and $X refused while released; each
energize written exactly once; the port's panel operations; both pairs of
home offsets, alone and at once; and a controller killed under a release,
whose replacement writes only 0 and 0.
Both pass against the driver's extensions tree. The poll cases fail against
the driver without its empty-line rule ("8 of 8 port jogs were refused under
a status poll"), which is the defect they were written from: it was found
on the bench reference with LightBurn connected, and the sender these
harnesses had until then polled a bare '?'.
|