Commit Graph
6 Commits
Author SHA1 Message Date
ScottW514 86ce0419e5 forgetest: cloud tests stay in cloud mode; the page can ignore prerequisites
The cloud job tests (lid-abort, lid-during-button-wait, hunt-lid-open,
pause-resume) run in cloud mode and leave the machine there: enter_cloud
reuses a live session (pid-scoped from the client's own websocket state
lines) and switches once from GRBL mode, declaring the change to the
baseline; nothing switches back. Each test judges the log from its own
window, the print by its own "print [id]: finished" line, and waits the
service's follow-up moves out (wait_quiet) before it ends. hunt-lid-open
restarts the cloud client through the supervisor's stop/start lever for
a fresh connect. The former switch-back is what failed the last bench run
of hunt-lid-open (409 machine is not idle: the service was still
re-finding the head after the lid closed).

The baseline is mode-aware: in cloud mode the client owns the GRBL
controller's init values, the lid lamp, and the position counters; the
mode itself is preserved unless the run declared the change
(Context.mode_changed); controller_mode is never handed back as a bare
setting (a bare write left the persisted mode out of step with the live
one). The undeclared-change restore now uses the captured state, which
the post pass never saw before.

The acceptance page gets an "Ignore prerequisites" switch (remembered by
the browser): POST /start {ignore_requires} starts a test whose requires
are unmet, and the run records the unmet prerequisites in its evidence
and log; they stay required for the release. The cloud tests' requires
no longer chain through cloud.mode-switch.

Proof: tests/test_cloud_suite.py replays the four tests on the bench's
own gfcloud excerpts (fixtures/) and the run loop's emitted pause/resume
lines under the real runner Context against a fake forgectrl; baseline
mode tests and the server override test; the whole suite (98) and the
coverage lint pass. Catalog consequence: cloud.* fingerprints move with
the module; the catalog hash moves with the requires.
2026-08-17 06:42:48 -04:00
ScottW514 9878c8d3b9 forgetest: kernel counters prove the return, and ring residue is a leftover that blocks the jog
The lid-cancel tests (motion.lid-cancel-home, laser.lid-cancel-mid-fire)
now check that the KERNEL position counters returned to the job start,
not only grbl's MPos - grbl's drift read 0.000 while the head had not
moved. The baseline reports unplayed bytes queued in the kernel ring
(cnc/position total minus processed) as a leftover and refuses its
return jog while any exist: a run started on top of them replays them
first, which is what put the head into the rail. BRINGUP item 16 records
the bench finding and the stream-engine fix.
2026-08-16 20:47:32 -04:00
ScottW514 b68d790b71 baseline: take the fresh-boot reference after the controller applied its config
/mode reports controller=running at the spawn, so the reference dump
raced grblHAL's init writes and captured the supervisor's motion-probe
values (motor_lock 0, step_freq 10000, y_mode at the module default)
instead of the resting state. boot_reference() now waits for the
controller's markers (step_freq/motor_lock/y_mode at their fixed values,
bounded 20 s, GRBL mode only) plus a 1 s settle before dumping, retakes
a saved reference that shows the pre-config state while the boot is
still fresh, and marks it otherwise. Tests cover the wait, its timeout,
the non-GRBL no-op, the pre-config recognition and the retake.
2026-08-16 20:00:08 -04:00
ScottW514 d0291ec7cb forgetest: the lid lamp idles at forgectrl's lid_lamp_idle; the liveness test masks and restarts
The lid lamp now has a resting policy in forgectrl (lid_lamp_idle,
default 236, asserted at start and at every spawn), so the baseline
expects it there instead of preserving whatever level a boot left, and
forgectrl.settings-bounds proves it: resting at the setting, 256 / -1 /
'bright' refused, a new level applied to the lamp at once, the cleared
key back to the default. Clearing a key goes through the query-string
form (an empty JSON value reads as no setting).

motion.liveness-probe adds the regression the bench needed: with every
axis masked (cnc/motor_lock=15, as a bench tool may leave it) forgectrl
is restarted and its fresh probe must read MOTION OK on the first try -
the probe unmasks the axes itself - and the controller comes up with the
mask cleared. Bench 2026-08-16: MOTION OK at p2p 2047/1341 against the
800 threshold, no ladder.

The baseline's settle no longer counts 'probe verified, spawn pending' as
settled (the post pass ran between the probe's own writes and the
controller's init writes and mis-flagged motor_lock/step_freq): it waits
for the controller to be running, with a bounded allowance for a respawn
backoff.
2026-08-16 15:07:34 -04:00
ScottW514 a80d7aabfb forgetest: cloud tests prove the session from the client's log and hand the head back
cloud.mode-switch took the optional connect-time firmware probe file as
the evidence of a live session and failed on a bench where that check is
off; the evidence is now gfcloud's own authenticate/ws-connect lines in
the unified log after the switch, the probe recorded when present. Cloud
mode's connect clears the kernel position counters at the head's start
and its hunt homes the head to the corner: the test tells the runner the
counters were re-zeroed (Context.counters_rezeroed) and jogs the head
back by the counter-measured displacement, and hands the lid lamp back
at the level it found. cloud.gfhome-homing documents that it leaves the
machine homed at the corner.

Baseline: a displaced head is jogged back along its own path by the
kernel-measured X/Y delta through the GRBL controller (bounded 100 mm,
waits out a controller respawn backoff); Z is never touched.
2026-08-16 14:21:54 -04:00
ScottW514 4aaedc8080 forgetest: every run starts from, and leaves, the fresh-boot idle state
A baseline pass brackets every test and bench tool: before the run the
machine is verified against the fresh-boot idle state and anything off it
is restored; after the run - pass, fail, or abort - it is restored again.
Fixed items are the resting values the boot establishes (module defaults,
forgectrl's start-up writes, the GRBL controller's init writes) and
forgectrl's idle picture (controller running with motion verified, no
diagnostic, camera and cooling engines idle); preserved items (lid lamp
level, position counters, settings map, controller mode) are captured
before and handed back after. Deviations are leftovers: in the run pane,
in the result's evidence, and on the page - attributed to the previous run
when found before, to the run itself when found after.

forgetest takes a fresh-boot reference once per boot (within ten minutes
of boot, after the supervisor settles) as the session's resting lid-lamp
level and the check on the fixed values; the values were confirmed
against a fresh boot of the dev image on the bench (step_freq rests at
28160, the controller's default tick, not the probe's 10000).

Takeover runs capture the controller-owned kernel attributes on entry and
write them back before forgectrl restarts: the bench found the kernel
tests leaving motor_lock=15 behind, which masked the supervisor's
liveness probe - no motion by construction, a false driver-wedge verdict,
the rail-off ladder, and finally motion-fault. The takeover wrapper also
waits for the supervisor to settle on both sides (moved into baseline).

Catalog consequence: none beyond the runner; the tests' own drills are
unchanged.
2026-08-16 13:35:19 -04:00