ScottW514 9c22240480 Hold the job start across a pause in the lifecycle harness
laser.pause-resume-lid-cancel failed on the bench with the head 14.925 mm
along the first leg after the lid cancel: the driver took every resume
from a feed hold as a new job start (the core restarts a held cycle
through Idle), so the cancel returned the head to the pause point and
said "returned to the job start" about it. The driver fix is in
grblHAL-glowforge; this is its proof and the record.

The null-sink lifecycle harness gains rule 9: a job paused and resumed by
the button, then cancelled by the lid, returns to where the job began
(reproduces the bench failure to the millimeter on the old driver,
X=13.088 instead of 0); and a job abandoned in a hold and soft-reset is
over, so the next job from that spot returns to that spot. The campaign
log carries the dated account.

No catalog consequence: the acceptance test measured exactly this and
stays as it is; the harness is the CI side of the same contract.
2026-08-21 13:00:56 -04:00
ScottW514 6b35f9c534 Arm-wait lid cancel expectations: reset banner and no alarm (harness, laser.arm-wait-lid, LIGHTBURN.md) 2026-08-16 19:31:42 -04:00
ScottW514 c4ea96127c Lid/button parity: harness cases, acceptance tests, operator and safety docs, BRINGUP item 16
laser_lifecycle_test.py: the button toggle (press = Hold, press = Run;
the arming press is not a pause), lid and interlock cancel mid-job with
the return to the job start and no alarm, and lid_policy=hold.

Acceptance catalog: motion.button-hold-resume, motion.lid-cancel-home
(operator: travel job, lid open -> cancel message, banner, no alarm,
autonomous return, Idle at the start), laser.lid-cancel-mid-fire (live:
emission stops in hardware, cancelled, returned, armed=false, latch
locked, hardware button latch SET). covers name the switch and laser
sources explicitly.

LIGHTBURN.md: what the lid, Stop and the button now do; SAFETY.md: the
door policy and the button as a software layer; BRINGUP.md: item 16
records the whole parity change (host-proven, bench validation pending)
and items 4/12 point at it.
2026-08-16 19:26:11 -04:00
ScottW514 36b4a3a5f4 Lid open during the arm wait: harness cases, laser.arm-wait-lid, operator doc
laser_lifecycle_test drives the controller's button wait through the
file-backed switch source (GF_SWITCH_FILE): a press with the lid closed
arms and nothing arms before it; the lid or the interlock loop opening
during the wait cancels the job (reason reported, alarm 3, never armed).

Acceptance catalog: laser.arm-wait-lid (operator kind - no press is
given, so nothing can fire) starts a laser job, has the operator open
the lid at the white-button prompt, and checks the cancel message,
alarm 3, armed=false, the kernel latch locked, no emission, and Idle
after $X. covers names glowforge_laser.c, glowforge_switches.c and
glowforge_switch_map.h explicitly.

LIGHTBURN.md: opening the lid or the interlock loop while the button is
lit cancels the job; a press with the lid open never arms.
2026-08-16 18:36:24 -04:00
ScottW514 6050c0e703 Unified logging: rsyslog as the system logger, the ForgeFIRM log tree
rsyslog replaces busybox syslogd/klogd (VIRTUAL-RUNTIME_base-utils-syslog,
trimmed PACKAGECONFIG) and becomes the only log writer: the appended
/etc/rsyslog.conf sets the inputs and the ff_line format and includes
the per-logger rules that `forgectrl --render-syslog` renders from the
machine settings at boot. forgefirm-logrotate becomes forgefirm-logging:
render before rsyslog starts (S19), sweep the pre-syslog log files into
/data/forgefirm/legacy-logs once, and rotate the tree at boot and hourly
by rename + HUP instead of copytruncate. Pins bumped to the pushed
forgectrl (syslog emitter, Logs tab, export), grblHAL-glowforge (syslog
emitter) and python3-gfhardware apps (syslog handlers, capture dir);
the CI harnesses set FFLOG_STDERR=1 so failure diagnostics keep the
controller's log lines. BRINGUP carries the bench validation checklist
(Next work item 14); this is an image change and rides the next flash.
2026-08-15 14:37:33 -04:00
ScottW514 cced57da6c bench: platform drills, cutting-power lid-IR and expected-stop live drills, SIGTERM lifecycle case
- platform_drills.py (on the board, forgectrl stopped): dead-man trip
  readback, rmmod/modprobe with concurrent attr reads, decay/microstep
  readback, LED sequence.
- live_fire_drills.py: ircut (S/F selectable characterization job),
  expstop (armed job + POST /controller/stop, controller left stopped),
  ctrlstart (separate, operator-approved resume); the token header is sent
  in exact case.
- laser_lifecycle_test.py: sigterm-mid-job - SIGTERM during an armed job
  must stop it, relock the latch and exit promptly.
2026-08-15 08:38:29 -04:00
ScottW514 26ed519348 bench: surface the controller stderr when the harness cannot connect
A startup failure previously reported only cannot-connect with the
process stderr discarded - undiagnosable in CI.
2026-08-14 19:10:38 -04:00
ScottW514 9e9d03ba94 bench: armed-window lifecycle harness (null-sink, host-side)
Four sessions against the reported messages: arm once per job with
M5/M3 persistence and the M2 close (grace pushed beyond the horizon so
only the program-end path can disarm); a displaced sender must re-arm;
the disarm grace counts down in Hold; a blocking cooling verdict
refuses the arm. Test-the-test proven: a build with the job-based
window reverted fails at the first discriminating assertion. Wired
into the controller repo CI alongside the emission harness.
2026-08-14 19:07:29 -04:00