The faultpos live-fire drill armed and commanded a cut at an origin it
called stale to test a refusal the design decided not to gate: its only
outcome was an emission at an unknown position. Removed from the script
and the bench page.
live_fire_drills.py discarded every drill's return value, so the bench
page recorded a failed live-fire drill as OK. The exit status is the
drill's.
laser_pgood is the supply's power-good, high on every healthy machine;
fire_test.py and the K3 drill aborted on it and pgood_probe.py inverted
it. The latch-unlock drills now gate on the safety chain holding HV off
(charge-pump watchdog dead, pulse engine idle), as the kernel suite
does, and the probe reports the pin as the kernel publishes it.
motion.deadman: the controller resumed from its hang recovers on $X and
moves again without a restart (the stream's fault acknowledgment).
Scope on GPIO2_IO30 (the SoC FIRE drive): two 2.000 s FIRE windows,
the second terminated only by the SDMA end-of-data backstop. Measured
2.0000 s exactly with clean edges on BOTH termination paths - normal
completion and true underrun (streaming=1, kernel underrun state
reached and acked; fire_test.py gains the U mode). The backstop drops
FIRE within one tick regardless of how the stream dies.
With the waveform, stream-path, latch, topology, and interlock-
semantics results from earlier today, every standing hardware
verification gate for live fire is now passed; what remains is the
laser-milestone software and a chain-armed first-light procedure.
fire_test.py phases A/B with the scope on the PSU LASER_ON pin, power
byte 0 throughout, HV unpowered, operator-executed unlock: latch LOCKED
severs FIRE entirely (pin flat + kernel laser_enable 0 under 40k
streamed fire bits); latch unlocked with the chain unarmed shows FIRE
live kernel-side while the PSU pin stays flat - the factory board
gates LASER_ON behind OK_2_FIRE exactly like the OpenGlow AND design.
interlock_circuit semantics pinned by the 13-to-7 transition: b0
LASER_ON monitor active low, b1 FIRE active high, b3 latch 1=locked.
The 1-tick FIRE drop measurement is deferred (SoC net inaccessible;
PSU pin needs an armed chain) - documented with both closure paths.