ScottW514 1e855ab212 The density floor closes the low end: a commanded 1 percent now marks
$35 = 10 under the density model is a density floor, not a duty floor. It
maps S onto 9.4-100 percent density, so a commanded 1 percent lands at
10.2 percent, just above the marking floor the earlier ladders measured.
A ladder reweighted to the bottom of the user scale - 1, 2, 5, 10, 20,
40, 70, 100 percent of S - marked on all eight rungs, with eight current
segments over a 42.0 s window against exactly 8 x 5.25, and segment means
climbing 136 to 968.

That meets the goal the ladders started from: a user's 1 percent is a
real visible mark rather than silence, and 100 percent is full power. It
took all three pieces - density so every level is real pulses, the
minimum pulse so they stay strikeable, the floor so the user's range sits
on the band that works.

dladder no longer tells the operator to re-run at other base periods to
choose one. The period cancels out of the low end, and what a failing
rung now indicates is a floor set too low.
2026-08-17 21:58:05 -04:00
ScottW514 ff454ed537 Retract the pulse-length conclusion; show the minimum in the drill table
The fifth ladder, the first with a minimum pulse, moved the floor down a
full rung: only 5 percent failed to mark, and 5 percent now strikes. The
trace carries eight current segments where the run before it had seven,
with fire beginning at 6.2 s exactly at rung 1 and the usual flat
saturated final segment anchoring the count from the other end.

That retracts what the previous entry concluded. Pulse length is not
irrelevant: 10 percent moved from no mark at F100, with three times the
dose per millimeter, to a mark at F300 at the same density, the only
change being its pulses growing from 36-71 us stubs to 106 us. The
matched-pairs argument was sound but drawn entirely from comparisons at
or above 20 percent density, where every pulse length in play was already
long enough - it generalized from the one regime where pulse length does
not bite. Above ~100 us dose governs; below it pulse length does; below
~36 us the supply does not strike. The factory's 100 us quantum sits on
that boundary.

dladder now reads laser_pulse_min_ticks and prints what is actually
emitted. Without that its table reports the pulse density alone would
give, which is wrong wherever the minimum applies - at min 6 the bottom
four rungs all emit 213 us and vary their rate instead, and the operator
reads that table to interpret the material.
2026-08-17 21:47:40 -04:00
ScottW514 b7091effb7 dladder: print the hv_current trace, like pthresh
The trace is the per-rung witness: the laser-off G0 between rungs reads
0, so the runs of nonzero current count the rungs that struck and their
level tracks each rung's dose. Without it a run reports only a range,
and which rungs fired has to be read off the material alone.
2026-08-17 20:55:39 -04:00
ScottW514 4eb0932099 Add the density ladder drill for choosing the dose base period
Under the FIRE-bit dose model the duty is pinned at full and the level
is carried by how many ticks of each base period fire, so a rung's pulse
is density x period - and the base period is the one parameter the host
cannot settle. dladder walks 5 to 100 percent of dose on scrap at
constant power, printing what each rung actually emits: density, mean
on-ticks, and the pulse the tube sees in ticks and microseconds. Below
one tick per period the pulse stays one tick and whole periods are
skipped instead, which the table says outright rather than quoting a
sub-tick average.

Run it at 20, then 40, then 10 on the same material. At 20 percent dose
that is 107-142 us, 249-284 us and 36-71 us respectively, which brackets
the 100 us the factory never goes below. The material answers two
questions: whether depth tracks density linearly, or the low end marks
harder than its share because every burst restarts the discharge and
carries the strike transient; and how short a burst still marks, which
is the floor a given base period can reach.

Preconditions are refusals, not warnings: laser_power_model must already
be density and $35 must be 0, since a floor lifts every rung off the
bottom of the range the drill exists to explore. The $35 message says a
runtime write is not enough - the S to duty mapping is precomputed when
the spindle is enabled. The drill writes laser_pulse_ticks itself when
it can reach the machine config, preserving every other line, and
refuses with instructions when run from a LAN host where it cannot.
2026-08-17 20:45:32 -04:00
ScottW514 cb41a6030c Commission the laser duty floor; record how the factory sets power
The pthresh ladder on scrap puts the tube's two thresholds far apart: the
discharge strikes between 2 and 3 percent duty, but nothing lases usefully
below 16 percent (PWMSAR 20), and the rungs between show only a spot at
each line start. $35 ships at 16 (grblhal-glowforge 9466f76, pinned here).

The drill said current lift-off and first mark share a rung; this run
falsifies that, so its docstring and read-the-material text now name both
thresholds and warn that a start-of-line spot is below the threshold, not
at it.

A start-of-line spot is also what a full-power leak at a kernel run start
would look like, so laser_stream_test gains a ladder session (rule 10):
every FIRE tick must ride a commanded duty, and the fire ticks must divide
evenly across rungs. Both hold exactly - six commanded duties, no others,
and 28296 fire ticks on every rung - so the spots are the tube, not the
stream. The harness now derives its expectations from the floor, which
moves the M4 session's S500 plateau from 63 to 73.

laser.power-floor is a new auto acceptance test, the suite's only
non-firing one: a machine must actually carry the commissioned floor,
since stored settings beat freshly baked defaults.

Three cloud cuts of one square at Precision Power 1, 100 and Full Power
show what the analog path is competing with: the power byte is pinned at
127 in all three, dose is FIRE-bit density on a fixed 7-tick period with
the on-count dithered between adjacent integers, and the power setting
never reaches the machine at all. Facts bank and item 17 carry the
numbers; CAMPAIGN-LOG carries both sessions.
2026-08-17 19:45:19 -04:00
ScottW514 faaa6cb40b Cover step timing under CPU contention; record the laser power model
Bump the grblHAL pin to the real-time producer change.

Add motion.step-timing-under-load: the catalog had nothing that
exercised step generation while userspace competed for the single core,
which is exactly the gap that let the condition go unnoticed - the ring
never runs dry, so cnc/underruns reads 0 through it. The test asserts
the producer and the shipper both hold SCHED_FIFO, then drives
2000 mm/min round trips against a deliberate nice-5 CPU hog and requires
the controller to report no clamped events.

Add the pthresh live-fire drill: a constant-power ladder from 2 % to
30 % of full on scrap. Because $35 is a percent of full duty and the
rungs are percents of $30 with $31 = 0, the lowest rung that marks reads
directly as the $35 value. It needs $35 = 0 for the run, or the floor
lifts every rung and hides the threshold.

Record both open items in BRINGUP. The laser one carries the finding
that the factory never uses duty as a power control - all five firing
jobs in the captured pulse files pin the power byte at 127 and modulate
dose by dithering the FIRE bit at 6.5-18.8 % density - so the captures
cannot supply a $35 default, and the duty to optical-power transfer
function of this supply has never been measured.
2026-08-17 16:45:37 -04:00
ScottW514 cd8a01a3d9 bench: every board-runnable tool ported to the bench page
The remaining bench diagnostics run from forgetest's #bench tab. The
tools that also run from a LAN host share scripts/bench/gfbench.py:
GF_HOST names a remote machine (host mode, sysfs through ssh, Grbl and
forgectrl over the LAN); unset, the tool runs on the board itself
(local mode, sysfs directly, everything on 127.0.0.1), which is how the
page runs them - with GF_HOST=127.0.0.1, the panel token in GF_TOKEN
and their data files under <data>/bench/ (FORGETEST_BENCH_DATA). The
helper also reads a machine setting from forgectrl, or from the settings
file on the board while forgectrl is stopped.

Ported: pwm_sweep / pwm_hold (scope = a takeover; the latch relocked,
the write refused if FIRE or LASER_ON reads active), pwm_stream_test
(PASS/FAIL exit), flow_characterize, flow_recheck_char,
flow_warm_validate and flow_matrix (takeovers: forgectrl owns the
thermal hardware, so the page's takeover replaces the tools' own
controller stop/restart, whose command line predated the supervisor;
results and logs in the bench data directory), flow_sustained,
fan_test, temp_calibrate (dry; watch bounded in seconds; the threshold
and the coolant conversion from the shared code), flow_escalate_drill
(cool_confirm_max_s shortened through forgectrl's settings for the
drill and restored; the setting's minimum is the default budget), and
live_fire_drills (<drill> [S] [F], all six drills, host from GF_HOST,
token from the board). flow_matrix joins the registry. What stays
unported cannot run against the machine at all: the two null-sink CI
harnesses and the .puls decoder.

Runner: a scope tool runs inside the takeover wrapper; the bench
environment above is passed to every tool. Tests: test_bench_registry
(registry <-> scripts/bench consistency, every ported tool builds its
command line, every script compiles, gfbench host/local modes) and the
server test (scope tool takeover, the environment reaching the tool).
Local mode smoke-run on the bench (temp_calibrate watch, setting, token)
from /tmp, removed after.

No catalog consequence: bench tools are not image components (dev-only
forgetest); the acceptance catalog is unchanged.
2026-08-16 16:28:39 -04:00
ScottW514 cced57da6c bench: platform drills, cutting-power lid-IR and expected-stop live drills, SIGTERM lifecycle case
- platform_drills.py (on the board, forgectrl stopped): dead-man trip
  readback, rmmod/modprobe with concurrent attr reads, decay/microstep
  readback, LED sequence.
- live_fire_drills.py: ircut (S/F selectable characterization job),
  expstop (armed job + POST /controller/stop, controller left stopped),
  ctrlstart (separate, operator-approved resume); the token header is sent
  in exact case.
- laser_lifecycle_test.py: sigterm-mid-job - SIGTERM during an armed job
  must stop it, relock the latch and exit promptly.
2026-08-15 08:38:29 -04:00
ScottW514 ea0642f942 Record live-fire drill results: emission witness, HV, lid-IR, X-3, G-10
Phase 5 A-1 emission witness and A-5 HV telemetry pass on live burns;
A-2 lid-IR characterized as a weak signal at 40% (gate left watch-only);
pgood confirmed unusable as a witness on this PSU. Phase 4 X-3 (0.1s
job-based disarm on M2) and G-10 (disarm counts down in Hold) pass.
Adds live_fire_drills.py (arm-lifecycle sampler over TCP + HTTP).
2026-08-14 21:14:57 -04:00