Retire next-work item 1: the fire watch is armed on the bench
The factory-shaped watch is implemented, host-tested and bench-proven with the lamp as the flame stand-in (CAMPAIGN-LOG has the run, the fault-class mapping and the recorded interpretation). BRINGUP: the item closed, items 2 to 18 are now 1 to 17, the references follow, and the facts bank reads the armed posture. Pin forgectrl for its doc fix.
This commit is contained in:
@@ -4846,6 +4846,48 @@ Host proof: the two table rows in `cool_gate_test`. This machine is not
|
||||
teardown-verified to carry the part, so the drive is proven at the GPIO;
|
||||
the first Pro on the bench proves the cooling itself.
|
||||
|
||||
## 2026-08-31: the fire watch, armed in the factory's shape
|
||||
|
||||
The lid-IR fire watch is redesigned, armed by default, and bench-proven
|
||||
on the hot-deployed board (forgectrl 77a6434, pinned in forgefirm
|
||||
b506e67). The four channels sorted ascending are the quartiles, the
|
||||
factory's own statistic (`IR?v` value tags exist for exactly those, and
|
||||
the thresholds ride on quartiles, not channels); a sustained first or
|
||||
second quartile over its alert threshold is the pause tier (verdict
|
||||
FLAME, hold, fire blocked, released once the signal clears), over its
|
||||
critical threshold the fail tier (motion stopped, latch locked, verdict
|
||||
FIRE until the next session, smoke airflow held) - the same two classes
|
||||
the factory's fault registry gives them (`lid_ir_*_quartile_alert` rings
|
||||
the pause chain, `lid_ir_*_quartile_critical` is a hard FAILURE). The
|
||||
watch runs through the run, smoke and thermal phases and gates both
|
||||
controller modes through the one verdict.
|
||||
|
||||
The knobs are four gate rows with the factory's header values as
|
||||
defaults: alert 275 / critical 688 on the first quartile, 374 / 1022 on
|
||||
the second, quartiles three and four left off as the factory leaves
|
||||
them at zero; 0 turns a tier off, and the cross-check keeps each alert
|
||||
under its critical. The defaults sit far above a fully lit lid lamp
|
||||
(161 to 177 counts plus 22 of drift), so no lamp change can trip them;
|
||||
a candle-sized flame (+3 to +6 counts) stays under them too - the watch
|
||||
catches a developed fire, which is what the factory's catches. The
|
||||
relative `cool_fire_ir_delta` watch retires; per-job baseline and peak
|
||||
logging stays. The header's own `IR??` values stay declared-ignored
|
||||
(the standing envelope decision); reading what the cloud sets, per
|
||||
machine, stays with the commissioning item. One interpretation is
|
||||
recorded rather than recovered: that the quartile values are the sorted
|
||||
instantaneous readings; the factory's exact computation is not decoded.
|
||||
|
||||
`cooling.fire-watch-tiers` passed on the deployed board (17:48Z), the
|
||||
lid lamp as the flame stand-in (idle readings 51 to 56): a q1 alert
|
||||
moved under the lamp held the session (verdict FLAME, `fire_watch`
|
||||
alert, hold, fire blocked, the reason naming the quartiles) and did not
|
||||
survive into a fresh session; a q1 critical latched FIRE with the laser
|
||||
latch locked (`interlock_circuit` bit 3); all four thresholds at zero
|
||||
read as the four flame gates off with the watch at `watch`; restored,
|
||||
the watch read `armed` at OK. A first run failed only on its own log
|
||||
check racing rsyslog by a second; the checks now poll the tail
|
||||
(forgefirm 678a155).
|
||||
|
||||
## Superseded status notes
|
||||
|
||||
### Shared machine services — remaining polish, as listed 2026-08-13
|
||||
@@ -6415,6 +6457,36 @@ entry above, with the CMet/CMdt correction); the catalog case is
|
||||
same passive closed-loop cooling), not teardown-verified per unit — another
|
||||
reason it is a setting.
|
||||
|
||||
### Fire watch (lid IR) redesign (item 1), closed 2026-08-31
|
||||
|
||||
Closed: armed in the factory's shape with knobs, bench-proven with the
|
||||
lamp as the flame stand-in (the entry above). Items 2 to 18 are now 1
|
||||
to 17.
|
||||
|
||||
1. **Fire watch (lid IR) redesign.** The gate stays disabled
|
||||
(`cool_fire_ir_delta = 0`) until it is lamp-aware: the engine must own or
|
||||
observe the lamp level (suspend the watch and re-baseline for a few ticks
|
||||
after any `lid_led` change) and the threshold must be relative to the
|
||||
lamp-set level, not a fixed count. Even then the signal is weak — a candle
|
||||
reads like a cut — so the head camera or a real flame sensor is the honest
|
||||
path to fire detection that means something.
|
||||
|
||||
One lead worth a bench hour before building anything. The cloud ships flame
|
||||
thresholds in every pulse header, and the numbers do not look lamp-naive:
|
||||
baseline 3 counts on all four channels, alert at 275 and critical at 688 on
|
||||
the first quartile, 374 and 1022 on the second, with the third and fourth
|
||||
left at zero. The lamp response (facts bank) puts a fully lit lamp at 161
|
||||
to 177 counts on every channel and the dark floor at 2, so the factory's
|
||||
alert sits above the lamp and its baseline matches the floor: the factory
|
||||
rides out the lamp by choosing thresholds above it rather than by tracking
|
||||
it, and the watch could be re-armed on fixed numbers after all. Still
|
||||
unproven: that the header's quartiles map onto the raw channels and share
|
||||
their units (all four channels behave alike, while the header leaves the
|
||||
third and fourth quartiles at zero). Confirm against the header the next
|
||||
cloud job carries. By decision those header thresholds (`IR??`) are the
|
||||
prior for this redesign and nothing else: the cloud client declares them
|
||||
ignored, and the watch stays disabled until it is lamp-aware.
|
||||
|
||||