mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-27 16:51:12 -07:00
Flow-detection experimental record and bench tooling
Adds the design matrix and its supporting tools, and records in BRINGUP what the 60-run matrix overturned: sub-40-percent duty mimics flow (three of five dead-pump trials looked healthier than a working pump), the operating point and threshold now rest on 25 pooled observations, periodic re-checks are thermally free with the fans running, and the settle gate closes a bench-proven miss. Also records what is NOT yet validated - warm-loop baselines and behaviour under laser heating - as first-light commissioning items.
This commit is contained in:
@@ -0,0 +1,110 @@
|
||||
#!/usr/bin/env python3
|
||||
"""Characterize a SHORT periodic flow re-check for use DURING a job.
|
||||
|
||||
Why a separate design from the job-start check: with the laser firing
|
||||
and coolant flowing, tube heat raises BOTH sensors, inflating a plain
|
||||
downstream-rise metric toward a false fault. With the pump stopped that
|
||||
heat never reaches the sensors at all (stagnant loop), so the no-flow
|
||||
signature stays at its idle value. The two signatures therefore
|
||||
converge during a cut. The differential rise
|
||||
|
||||
(downstream_end - downstream_start) - (upstream_end - upstream_start)
|
||||
|
||||
cancels that common-mode heating and is the metric this measures.
|
||||
|
||||
TWO DEAD ENDS, recorded so they are not re-invented:
|
||||
|
||||
1. Absolute over-temperature does NOT detect a failed pump. The
|
||||
sensors read the water at their own location; with no circulation
|
||||
the tube's heat stays in the tube and never reaches them. The loop
|
||||
can read perfectly comfortable while the tube cooks. Over-temp
|
||||
monitoring detects a hot CIRCULATING loop - a different failure.
|
||||
|
||||
2. "The coolant should warm up while cutting" is NOT a usable
|
||||
indicator either. A low-duty engrave (say 5% duty at 30% power) can
|
||||
put so little heat in that the cooling system absorbs it with no
|
||||
measurable rise, so a flat trend is equally consistent with a light
|
||||
load working correctly and with a dead pump. Ambiguous evidence is
|
||||
worse than none - it invites false confidence.
|
||||
|
||||
Hence: periodic ACTIVE interrogation with the heater, which creates a
|
||||
known stimulus instead of waiting for one, is the only valid method on
|
||||
this hardware (there is no pump tach or pump current sense anywhere in
|
||||
the machine).
|
||||
|
||||
Usage: flow_recheck_char.py [heater_pct] [window_s] (default 50 30)
|
||||
Runs both flow and no-flow cases from a comparable loop state and
|
||||
prints the differential separation. Aborts if downstream passes 45 C.
|
||||
"""
|
||||
import math
|
||||
import subprocess
|
||||
import sys
|
||||
import time
|
||||
|
||||
HOST = '172.16.1.97'
|
||||
F = 1024.0 * 1.3
|
||||
RD, BETA = 10000.0, 3380.0
|
||||
RINF = 10000.0 * math.exp(-3380.0 / 298.15)
|
||||
DOWN_ABORT_C = 45.0
|
||||
|
||||
|
||||
def degc(raw):
|
||||
r = RD / (F / raw - 1.0)
|
||||
return BETA / math.log(r / RINF) - 273.15
|
||||
|
||||
|
||||
def board(cmd):
|
||||
r = subprocess.run(['wsl', '-d', 'forge-yocto', '--', 'ssh',
|
||||
'-o', 'PreferredAuthentications=none',
|
||||
'root@' + HOST, cmd],
|
||||
capture_output=True, text=True, timeout=30)
|
||||
return r.stdout.strip()
|
||||
|
||||
|
||||
def sample():
|
||||
o = board('cat /sys/glowforge/pic/water_temp_1 /sys/glowforge/pic/water_temp_2').split()
|
||||
return degc(int(o[0])), degc(int(o[1]))
|
||||
|
||||
|
||||
def settle(seconds=100):
|
||||
board('echo 1 > /sys/glowforge/thermal/water_pump_on; echo 0 > /sys/glowforge/thermal/heater_pwm')
|
||||
time.sleep(seconds)
|
||||
|
||||
|
||||
def check(tag, pump_on, pct, window):
|
||||
board('echo %d > /sys/glowforge/thermal/water_pump_on' % (1 if pump_on else 0))
|
||||
time.sleep(2)
|
||||
d0, u0 = sample()
|
||||
board('echo %d > /sys/glowforge/thermal/heater_pwm' % int(65535 * pct / 100))
|
||||
t0 = time.time()
|
||||
d, u = d0, u0
|
||||
while time.time() - t0 < window:
|
||||
time.sleep(5)
|
||||
d, u = sample()
|
||||
print(' %-8s t=%2.0fs down=%5.2f (%+5.2f) up=%5.2f (%+5.2f) diff=%+5.2f'
|
||||
% (tag, time.time() - t0, d, d - d0, u, u - u0, (d - d0) - (u - u0)), flush=True)
|
||||
if d >= DOWN_ABORT_C:
|
||||
print(' abort: downstream at safety limit', flush=True)
|
||||
break
|
||||
board('echo 0 > /sys/glowforge/thermal/heater_pwm; echo 1 > /sys/glowforge/thermal/water_pump_on')
|
||||
return (d - d0) - (u - u0), d - d0
|
||||
|
||||
|
||||
pct = int(sys.argv[1]) if len(sys.argv) > 1 else 50
|
||||
window = int(sys.argv[2]) if len(sys.argv) > 2 else 30
|
||||
|
||||
print('=== periodic re-check characterization: %d%% heater, %d s window' % (pct, window))
|
||||
settle()
|
||||
print(' flow case:')
|
||||
flow_diff, flow_rise = check('flow', True, pct, window)
|
||||
settle()
|
||||
print(' no-flow case:')
|
||||
noflow_diff, noflow_rise = check('noflow', False, pct, window)
|
||||
settle(60)
|
||||
|
||||
print()
|
||||
print('differential rise: flow %+.2f no-flow %+.2f separation %.2f C'
|
||||
% (flow_diff, noflow_diff, noflow_diff - flow_diff))
|
||||
print('plain down rise: flow %+.2f no-flow %+.2f separation %.2f C'
|
||||
% (flow_rise, noflow_rise, noflow_rise - flow_rise))
|
||||
print('suggested differential threshold: %.2f C' % ((flow_diff + noflow_diff) / 2))
|
||||
Reference in New Issue