Flow-detection experimental record and bench tooling

Adds the design matrix and its supporting tools, and records in BRINGUP
what the 60-run matrix overturned: sub-40-percent duty mimics flow
(three of five dead-pump trials looked healthier than a working pump),
the operating point and threshold now rest on 25 pooled observations,
periodic re-checks are thermally free with the fans running, and the
settle gate closes a bench-proven miss. Also records what is NOT yet
validated - warm-loop baselines and behaviour under laser heating - as
first-light commissioning items.