The coolant critical tier, with its catalog test
forgectrl pin a1875a8: cool_temp_critical_c (default 38 C) is the fail tier above the coolant ceiling's pause: at or over it in a run session the verdict is CRITICAL (fire blocked, hold, no resume this job), the fault ends with the session, the settings API keeps it above the ceiling, and its top turns the gate off. Catalog: cooling.critical-tier (auto, 45 tests), driven through the settings API like cooling.gate-off: a critical line at the ceiling is refused (and undone should it ever be accepted); with the ceiling, the resume gate and the critical line all under the coolant's temperature a session reads CRITICAL rather than OVERTEMP with no resume and the reason naming the tier and the coolant; after the session the ceiling alone holds (OVERTEMP); with the critical line at its top the gate is off (gates_off, the run-start log line) and the ceiling alone pauses; restored, OK with nothing off. Four unit cases against a scripted engine. _after_session takes the condition to wait for. Docs: COOLING (verdict table, section 5, the settings table, the quick reference), BRINGUP item 19 and the catalog count, the CAMPAIGN-LOG paragraph for the fan-fault session rule on dev image 20260822145201.
This commit is contained in:
@@ -239,14 +239,17 @@ def _run_session(ctx, g, fc, until, what, wait=None):
|
||||
_session_ended(ctx, fc, what)
|
||||
|
||||
|
||||
def _after_session(ctx, fc, wait=5):
|
||||
"""The engine's state a few ticks after a session ended."""
|
||||
def _after_session(ctx, fc, wait=5, until=None):
|
||||
"""The engine's state a few ticks after a session ended: the first
|
||||
sample out of phase run that satisfies `until` (default: verdict OK),
|
||||
or the last sample taken."""
|
||||
until = until or (lambda c: c.get("verdict") == "OK")
|
||||
c = {}
|
||||
t0 = time.time()
|
||||
while time.time() - t0 < wait:
|
||||
ctx.sleep(1)
|
||||
c = _cool(fc)
|
||||
if c.get("phase") != "run" and c.get("verdict") == "OK":
|
||||
if c.get("phase") != "run" and until(c):
|
||||
break
|
||||
return c
|
||||
|
||||
@@ -353,6 +356,125 @@ def gate_off(ctx):
|
||||
ctx.check(fc.wait_idle(60, abort=ctx.aborted), "machine did not return to idle")
|
||||
|
||||
|
||||
CRIT_KEYS = ("cool_temp_max", "cool_temp_resume", "cool_temp_critical_c")
|
||||
|
||||
|
||||
@test("cooling.critical-tier", title="The coolant critical line is a fault above the ceiling's pause",
|
||||
subsystem="cooling", kind="auto", mode="grbl", est_min=3,
|
||||
covers=_COOL_COVERS + [("forgectrl", "src/main.c")], requires=["cooling.gate-off"],
|
||||
steps=["Machine idle, coolant at room temperature (above 8 C). The test writes the coolant "
|
||||
"ceiling, the resume gate and the critical line and restores them; three short M8/M9 "
|
||||
"cycles spin the fans."],
|
||||
description="Two tiers on the upstream coolant sensor: the ceiling pauses (OVERTEMP, resume "
|
||||
"below the resume gate), the critical line above it is a fault. With the ceiling "
|
||||
"and the critical line both under the coolant's temperature a run session must "
|
||||
"read CRITICAL rather than OVERTEMP (fire blocked, hold, no resume), the fault "
|
||||
"must end with the session, and the settings API must refuse a critical line at "
|
||||
"or below the ceiling; with the critical line at its top the gate is off by "
|
||||
"value (gates_off names it) and the ceiling alone pauses; restored, the next "
|
||||
"session runs OK with nothing off.")
|
||||
def critical_tier(ctx):
|
||||
fc = ctx.forgectrl
|
||||
ev = ctx.evidence
|
||||
before = fc.settings()
|
||||
orig = {k: before.get(k, "") for k in CRIT_KEYS}
|
||||
ev["orig"] = orig
|
||||
ctx.log("original: %s", orig)
|
||||
up = (fc.status().get("coolant") or {}).get("up_c")
|
||||
ctx.check(up is not None and up > 8.0, "coolant too cold for the trip leg (up_c %s)", up)
|
||||
c0 = _cool(fc)
|
||||
ctx.check(c0.get("verdict") == "OK" and c0.get("gates_off") == [],
|
||||
"engine is not at OK with every gate on before the test: %s", c0)
|
||||
gates = before.get("gates") or {}
|
||||
ceil = gates.get("cool_temp_max") or {}
|
||||
crit = gates.get("cool_temp_critical_c") or {}
|
||||
ctx.check(crit.get("gate") == "coolant_critical" and crit.get("off") == "high",
|
||||
"settings reply does not describe the critical line as the coolant_critical gate, off at "
|
||||
"its top: %s", crit)
|
||||
bottom, top = ceil.get("lo"), crit.get("hi")
|
||||
ctx.check(isinstance(bottom, (int, float)) and isinstance(top, (int, float)),
|
||||
"no ranges in the reply: %s %s", ceil, crit)
|
||||
ctx.check(isinstance(crit.get("lo"), (int, float)) and crit.get("lo") > bottom,
|
||||
"the critical line's floor %s is not above the ceiling's %s", crit.get("lo"), bottom)
|
||||
|
||||
# The cross-check: a critical line at or below the ceiling is refused
|
||||
# before anything is written.
|
||||
st, body = fc.post("/settings", params={"cool_temp_max": "33", "cool_temp_critical_c": "33"})
|
||||
ev["cross_check"] = {"status": st, "body": body}
|
||||
if st == 200:
|
||||
fc.post("/settings", params=orig) # undo before failing
|
||||
ctx.check(st == 400, "a critical line equal to the ceiling was accepted: %s %s", st, body)
|
||||
after = fc.settings()
|
||||
ctx.check(all(after.get(k, "") == orig[k] for k in CRIT_KEYS),
|
||||
"the refused POST changed a setting: %s", {k: after.get(k) for k in CRIT_KEYS})
|
||||
|
||||
restored = False
|
||||
with ctx.grbl() as grbl:
|
||||
st = grbl.status_report()
|
||||
ctx.check(st["state"].startswith("Idle"), "controller is %s", st["state"])
|
||||
try:
|
||||
# Leg 1: ceiling and critical line both under the coolant's
|
||||
# temperature. The fail tier wins: CRITICAL, not OVERTEMP.
|
||||
low = {"cool_temp_max": str(bottom + 1), "cool_temp_resume": str(bottom),
|
||||
"cool_temp_critical_c": str(bottom + 2)}
|
||||
_set_gates(ctx, fc, low)
|
||||
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "CRITICAL", "critical leg")
|
||||
ev["critical"] = c
|
||||
ctx.check(c.get("verdict") == "CRITICAL",
|
||||
"critical line %s C with coolant at %.1f C did not fault (verdict %s): %s",
|
||||
bottom + 2, up, c.get("verdict"), c)
|
||||
ctx.check(c.get("fire_ok") is False and c.get("hold") is True,
|
||||
"CRITICAL without fire blocked and a hold: %s", c)
|
||||
ctx.check(c.get("resume_ok") is not True, "a coolant fault offered a resume: %s", c)
|
||||
ctx.check("CRITICAL" in (c.get("reason") or "") and "coolant" in (c.get("reason") or ""),
|
||||
"the reason does not name the tier and the coolant: %r", c.get("reason"))
|
||||
ctx.check(c.get("gates_off") == [], "a tripped gate is not an off gate: %s", c.get("gates_off"))
|
||||
# The fault ends with the session; the ceiling, still under the
|
||||
# coolant, keeps its pause (OVERTEMP), never CRITICAL.
|
||||
c = _after_session(ctx, fc, until=lambda c: c.get("verdict") != "CRITICAL")
|
||||
ev["critical_after"] = c
|
||||
ctx.check(c.get("verdict") == "OVERTEMP",
|
||||
"after the faulted session the engine reads %s, expected the ceiling's OVERTEMP: %s",
|
||||
c.get("verdict"), c)
|
||||
|
||||
# Leg 2: the critical line at its top is the gate off; the
|
||||
# ceiling alone pauses, and gates_off says so.
|
||||
_set_gates(ctx, fc, {"cool_temp_critical_c": str(top)})
|
||||
c = _run_session(ctx, grbl, fc,
|
||||
lambda c: c.get("verdict") == "OVERTEMP" and "coolant_critical" in (c.get("gates_off") or []),
|
||||
"critical off leg")
|
||||
ev["critical_off"] = c
|
||||
ctx.check(c.get("verdict") == "OVERTEMP",
|
||||
"with the critical line off the ceiling did not pause (verdict %s): %s", c.get("verdict"), c)
|
||||
ctx.check("coolant_critical" in (c.get("gates_off") or []),
|
||||
"gates_off %s lacks coolant_critical", c.get("gates_off"))
|
||||
ctx.check(_tail_has(fc, "gate coolant_critical OFF: cool_temp_critical_c = %g" % top),
|
||||
"the run-start log line for the off gate is missing from the forgectrl log")
|
||||
|
||||
# Restore, and prove it: OK, nothing off.
|
||||
_set_gates(ctx, fc, orig)
|
||||
restored = True
|
||||
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "OK" and not c.get("gates_off"),
|
||||
"restored")
|
||||
ev["restored"] = c
|
||||
ctx.check(c.get("verdict") == "OK" and c.get("gates_off") == [],
|
||||
"engine did not return to OK with every gate on after the restore: %s", c)
|
||||
finally:
|
||||
if not restored:
|
||||
st, body = fc.post("/settings", params=orig)
|
||||
ctx.log("restore on failure: POST /settings %s -> %s", orig, st)
|
||||
try:
|
||||
c = _run_session(ctx, grbl, fc,
|
||||
lambda c: c.get("verdict") == "OK" and not c.get("gates_off"),
|
||||
"restore on failure")
|
||||
ctx.log("restore on failure: engine %s gates_off %s", c.get("verdict"), c.get("gates_off"))
|
||||
except Exception as e: # the original failure is the one to report
|
||||
ctx.log("restore on failure: run session did not complete (%s)", e)
|
||||
after = fc.settings()
|
||||
ctx.check(all(after.get(k, "") == orig[k] for k in CRIT_KEYS),
|
||||
"settings not restored: %s", {k: after.get(k) for k in CRIT_KEYS})
|
||||
|
||||
|
||||
FAN_KEYS = ("cool_tach_exhaust_min_rpm", "cool_purge_min_current", "cool_fan_grace_s")
|
||||
FAN_GRACE_S = "8" # past the intakes' 7 s to 90 percent, so only the leg's floor trips
|
||||
FAN_TRIP_WAIT_S = 20 # grace + three ticks, with slack for the 1 Hz pipeline
|
||||
|
||||
Reference in New Issue