Remove history narrative and audit references from docs and tooling
temp_calibrate now cross-checks the factory B-equation instead of the retired linear guess.
This commit is contained in:
@@ -1,9 +1,9 @@
|
||||
#!/usr/bin/env python3
|
||||
"""Phase 3.2 software check: laser PWM carrier frequency from PWM2 registers.
|
||||
"""Software check: laser PWM carrier frequency from PWM2 registers.
|
||||
|
||||
Expected with the fsl,extra-prescale=<13> fix: PWMCR prescaler divider = 13,
|
||||
PWMPR ~125 (127 counts - 2), effective carrier = perclk / (13 * 127) ~= 40 kHz.
|
||||
Without the fix: divider 1 -> ~520 kHz (audit M8). Safe: read-only register
|
||||
Without the fix: divider 1 -> ~520 kHz. Safe: read-only register
|
||||
inspection; the laser PWM output feeds the PSU power input, firing stays gated
|
||||
by the hardware chain. The definitive gate remains the scope on LASER_PWM.
|
||||
"""
|
||||
|
||||
Reference in New Issue