Record audit Phase 4; LIGHTBURN: the armed window is job-based

BRINGUP gains the Phase 4 (stale-gate cluster) record - code-complete,
host-verified, hot-deployable, bench drills listed. LIGHTBURN.md now
describes the job-based armed window: relock at program end, on a
sender change, or after the spindle-off grace (counting even in Hold).
This commit is contained in:
ScottW514
2026-08-14 16:58:35 -04:00
parent daa76ca828
commit ea3fce2efd
2 changed files with 42 additions and 4 deletions
+6 -3
View File
@@ -33,9 +33,12 @@ The laser fires only inside an operator-armed window:
runs. If nobody presses within `laser_button_timeout_s` (default
300 s) the job aborts with alarm 3. Stop in LightBurn (soft reset)
cancels the wait at any time.
- One press covers the whole job — power changes and M5/M3 toggles do
not re-prompt. The window relocks after `laser_disarm_s` (default
60 s) of idle with the spindle off; the next job prompts again.
- One press covers one job — power changes and M5/M3 toggles do not
re-prompt. The window relocks when the job ends (program end
`M2`/`M30`), when the sender connection changes, or after
`laser_disarm_s` (default 60 s) with the spindle off — counting even
while a job sits paused in Hold or with the lid open; the next job
prompts again.