cloud.pause-resume reads the job's limits through; pin the pass-through

The pulse header's envelope now reaches the cooling engine: the cloud
client (python3-gfhardware c34faa1) derives the coolant window and the
fans' minimum speeds from the header and rides them on every report,
and the engine (forgectrl 57f6064) resolves each as the stricter of its
setting and the job's, never looser and never overruling an off gate.
cloud.pause-resume, which runs a real print, now also reads the client's
"job limits from the header:" line and the engine's "effective limits:"
line from the two logs; two host cases cover the failure paths. The
needle guard lists the engine's phrases as not the app's.

COOLING.md section 2 explains what a cloud job brings with it; BRINGUP
item 19 records the pass-through as landed. Pins: forgectrl 57f6064,
forgefirm-app c34faa1 (0.1.14+git); fetch-verified.
This commit is contained in:
ScottW514
2026-08-21 18:07:41 -04:00
parent 8ad3f79e26
commit d530f773e2
7 changed files with 98 additions and 13 deletions
+23 -1
View File
@@ -15,6 +15,11 @@ _CLOUD_COVERS = [("forgefirm-app", "**"), ("python3-gfhardware", "**"), ("python
GF_LATEST = "/data/forgefirm/gf-latest.json"
GFCLOUD_LOG = "/data/log/forgefirm/gfcloud/gfcloud.log"
FORGECTRL_LOG = "/data/log/forgefirm/forgectrl/forgectrl.log"
# The client names the limits it derived from the pulse header once per
# job; the engine names the effective set whenever it changes.
LIMITS_MARK = "job limits from the header: "
EFFECTIVE_MARK = "effective limits: coolant ceiling "
SESSION_MARKS = ("authenticate_machine SUCCESS", "ws_connect ESTABLISHED")
RETURN_MAX_MM = 600.0 # the head comes back from the home corner across the bed
@@ -761,6 +766,7 @@ def hunt_lid_open(ctx):
def pause_resume(ctx):
ev = ctx.evidence
offset = enter_cloud(ctx)
fc_offset = log_size(FORGECTRL_LOG)
ctx.instruct(APP_PRINT_CUE)
got = wait_print_running(ctx, offset, 300)
ctx.check(got, "the print never reached its run within 300 s (not started, or the button not pressed)")
@@ -825,9 +831,25 @@ def pause_resume(ctx):
ctx.confirm("Did the app show the print's progress advancing while it cut, rather than "
"standing still or jumping straight to nearly finished?")
# The job's envelope, from the same print: the client derives the
# limits the header carries (a cut job carries the coolant window and
# the air-assist tach maximum) and hands them to the engine with every
# report, and the engine names the effective set it is running on,
# with the header's ceiling beside its own.
limits = next((ln.split(LIMITS_MARK, 1)[1].strip() for ln in lines if LIMITS_MARK in ln), None)
ev["header_limits"] = limits
ctx.log("job limits from the header: %s", limits)
ctx.check(limits is not None, "the client named no job limits from the header")
ctx.check("coolant_max_c=" in limits, "the header's coolant ceiling did not reach the engine: %s", limits)
eff = [ln.strip()[:200] for ln in log_lines_since(FORGECTRL_LOG, fc_offset) if EFFECTIVE_MARK in ln]
ev["effective_limits"] = eff[-3:]
ctx.log("engine effective limits: %s", eff[-1] if eff else None)
ctx.check(any("header " in ln and "header none" not in ln for ln in eff),
"the engine never resolved an effective ceiling against the header's: %s", eff[-2:])
settle_cloud(ctx, offset)
ctx.log("PASS: button pause/resume mid-print, warm-up and rest observed, progress reported, "
"job completed and parked")
"the job's limits passed through, job completed and parked")
@test("cloud.oversize-stream", title="A print longer than the ring is fed while it plays",