cloud.pause-resume reads the job's limits through; pin the pass-through
The pulse header's envelope now reaches the cooling engine: the cloud client (python3-gfhardware c34faa1) derives the coolant window and the fans' minimum speeds from the header and rides them on every report, and the engine (forgectrl 57f6064) resolves each as the stricter of its setting and the job's, never looser and never overruling an off gate. cloud.pause-resume, which runs a real print, now also reads the client's "job limits from the header:" line and the engine's "effective limits:" line from the two logs; two host cases cover the failure paths. The needle guard lists the engine's phrases as not the app's. COOLING.md section 2 explains what a cloud job brings with it; BRINGUP item 19 records the pass-through as landed. Pins: forgectrl 57f6064, forgefirm-app c34faa1 (0.1.14+git); fetch-verified.
This commit is contained in:
+10
-2
@@ -1325,8 +1325,16 @@ Open items only. Anything closed is in `CAMPAIGN-LOG.md`.
|
||||
flow window and the flow rise (`forgectrl/src/gates.c`, `SERVICES.md`
|
||||
"Gate settings", `COOLING.md` §8a, `cooling.gate-off` in the catalog,
|
||||
bench PASS 2026-08-21 on dev image `20260821210903`).
|
||||
The fan gates, the pass-through of header limits, the coolant critical
|
||||
tier and the watch-only board temperatures follow on it.
|
||||
**The pass-through is in:** the cloud client derives the job's limits
|
||||
from the header (`CMrx`/`CMrn` as degrees, `EFrx`/`IFrx`/`AArx` as the
|
||||
minimum speeds their maximum periods mean) and rides them on every
|
||||
`/cool/state`; the engine resolves each as the stricter of local and
|
||||
header, never loosening and never overruling an off gate, logs the
|
||||
effective set and publishes it in `/cool/status`; the coolant ceiling
|
||||
is the live consumer, the floors wait for the fan gates
|
||||
(`cloud.pause-resume` checks both log lines on a real print). The fan
|
||||
gates, the coolant critical tier and the watch-only board temperatures
|
||||
follow.
|
||||
|
||||
Nothing here can put energy where it was not commanded: the hardware chain
|
||||
is the emission boundary and no header field touches it, and forgectrl runs
|
||||
|
||||
Reference in New Issue