Commission the laser duty floor; record how the factory sets power
The pthresh ladder on scrap puts the tube's two thresholds far apart: the discharge strikes between 2 and 3 percent duty, but nothing lases usefully below 16 percent (PWMSAR 20), and the rungs between show only a spot at each line start. $35 ships at 16 (grblhal-glowforge 9466f76, pinned here). The drill said current lift-off and first mark share a rung; this run falsifies that, so its docstring and read-the-material text now name both thresholds and warn that a start-of-line spot is below the threshold, not at it. A start-of-line spot is also what a full-power leak at a kernel run start would look like, so laser_stream_test gains a ladder session (rule 10): every FIRE tick must ride a commanded duty, and the fire ticks must divide evenly across rungs. Both hold exactly - six commanded duties, no others, and 28296 fire ticks on every rung - so the spots are the tube, not the stream. The harness now derives its expectations from the floor, which moves the M4 session's S500 plateau from 63 to 73. laser.power-floor is a new auto acceptance test, the suite's only non-firing one: a machine must actually carry the commissioned floor, since stored settings beat freshly baked defaults. Three cloud cuts of one square at Precision Power 1, 100 and Full Power show what the analog path is competing with: the power byte is pinned at 127 in all three, dose is FIRE-bit density on a fixed 7-tick period with the on-count dithered between adjacent integers, and the power setting never reaches the machine at all. Facts bank and item 17 carry the numbers; CAMPAIGN-LOG carries both sessions.
This commit is contained in:
@@ -2599,6 +2599,182 @@ binned modes, 4.1× and 16.4× fewer bytes, which shortens the stall rather
|
||||
than merely spacing stalls out) and the churn re-base (which is what
|
||||
would allow a lead beyond 10 ms). Tracked in BRINGUP "Next work" item 16.
|
||||
|
||||
## 2026-08-17 — the laser duty threshold ladder
|
||||
|
||||
The first owed step of "Next work" item 17: measure where the tube starts
|
||||
lasing, so `$35` can stop M4's velocity-scaled power falling below it.
|
||||
|
||||
### The run
|
||||
|
||||
`live_fire_drills.py pthresh 1000 300` on wood scrap, operator-run on dev
|
||||
image `20260817220126`, machine idle and homed, coolant 23.9/24.1 °C. The
|
||||
precondition was read off the machine first: `$30`=1000, `$31`=0, `$32`=1,
|
||||
**`$35`=0.0**, `$36`=100 — no floor in place to lift the rungs.
|
||||
|
||||
Thirteen rungs, 2 %…30 % of full, 25 mm each at F300, constant power (M3),
|
||||
3 mm of `+Y` between them. Before firing, the two conversions were checked
|
||||
against each other: a rung of *P* % sends `S = 10·P`, which the core maps to
|
||||
`floor(127·P/100)` counts, and `$35 = P` computes `min_value =
|
||||
(uint)(127·P/100)` — the same integer, so the rung's percent *is* the `$35`
|
||||
value exactly, not approximately.
|
||||
|
||||
### What came back
|
||||
|
||||
Material, counting from the first rung drawn: rung 1 (2 %) nothing at all;
|
||||
rungs 2–9 (3–14 %) a tiny spot at the start of each line and a dark line
|
||||
after it; rungs 10–13 (16–30 %) continuous marks.
|
||||
|
||||
The `hv_current` trace agrees independently. It holds 0 for 19.5 s (arm
|
||||
wait), then runs nonzero to 82.8 s, immediately before Idle. Within it the
|
||||
laser-off `G0` between rungs reads 0, so the current runs count the rungs:
|
||||
**12 segments of ~4.7 s at a ~5.27 s period, not 13.** The last segment ends
|
||||
at the job end, so it is rung 13; counting back 12 puts the first current at
|
||||
rung 2. Rung 1 drew no measurable discharge current — the same rung that
|
||||
left no mark, from a completely separate witness.
|
||||
|
||||
So the tube has **two thresholds, far apart**:
|
||||
|
||||
| | rung | duty | witness |
|
||||
|---|---|---|---|
|
||||
| Discharge strikes | 2 (3 %) | PWMSAR 3 | current lifts off; spot only |
|
||||
| Sustained lasing | 10 (16 %) | PWMSAR 20 | first continuous mark |
|
||||
|
||||
Between them, 3–14 % is a **dead band**: current flows and climbs (per-rung
|
||||
means 133 → 289 raw) with essentially no light out. Each line's opening spot
|
||||
is the strike transient; the tube lights, drops below lasing gain, and coasts
|
||||
dark for the remaining 25 mm.
|
||||
|
||||
This falsifies the drill's own guidance, which said the current "lifts off
|
||||
baseline at the same rung the material starts marking" — lift-off is rung 2,
|
||||
marking is rung 10. The docstring and the printed read-the-material text were
|
||||
corrected to name both thresholds and to tell the operator that a rung
|
||||
showing only a start-of-line spot is *below* the threshold, not at it.
|
||||
|
||||
Raw `hv_current` is a presence/absence witness only. Per-rung means are
|
||||
non-monotonic at the top (429 at 20 %, then 311 and 302) and the variance
|
||||
collapses on the top two rungs, which is what an aliased point-sample of a
|
||||
pulsed current looks like; the signal has no characterized transfer function.
|
||||
|
||||
### Ruling out the firmware explanation for the spots
|
||||
|
||||
A start-of-line spot is also what a full-power leak would look like: a kernel
|
||||
run start resets the hardware duty to ~100 %, so a fire bit reaching the
|
||||
stream ahead of its power byte would burn at full power. The material already
|
||||
argued against it — rung 1 is the first fire of the run, the likeliest place
|
||||
for such a leak, and it is blank — but the stream is the record, so
|
||||
`laser_stream_test.py` gained a fourth session (rule 10): a ladder in the same
|
||||
shape, full power deliberately absent, asserting that every FIRE tick rides a
|
||||
commanded duty and that the fire ticks divide evenly across rungs (a rung
|
||||
opening at its neighbor's duty shows up as a surplus on one and a deficit on
|
||||
the next).
|
||||
|
||||
Result on the native build: duties under FIRE were exactly `[22, 23, 26, 32,
|
||||
41, 52]`, nothing else, and **28296 fire ticks on every rung, identical to the
|
||||
tick**. No full-power window, no stale-duty window. The spots are the tube and
|
||||
supply, not the firmware.
|
||||
|
||||
### What landed
|
||||
|
||||
- `DEFAULT_SPINDLE_PWM_MIN_VALUE 16.0f` in `boards/glowforge.h` — the
|
||||
measured lasing rung. Chosen over the next rung up (20 %) because the floor
|
||||
is spent at corners, where velocity and dose per unit length already move
|
||||
the wrong way, and because `$35` is a user setting anyone can raise.
|
||||
- The harness now derives its expectations from that floor (`duty_for()`), so
|
||||
the M4 session's S500 plateau moved 63 → 73 and its ramp `[44, 52, 63, 127]`
|
||||
→ `[57, 64, 73, 127]`, plus a new check that no duty under FIRE falls below
|
||||
the floor. All four sessions pass, as do `switch_map_test`, `laser_arm_test`
|
||||
and `laser_lifecycle_test`.
|
||||
- `laser.power-floor`, an auto acceptance test (the suite's only non-firing
|
||||
one): reads `$$` and checks the machine actually carries the commissioned
|
||||
floor, since stored settings beat freshly baked defaults and a machine with
|
||||
an older EEPROM needs `$RST=$` once. Coverage lint clean at 40 tests.
|
||||
|
||||
### What it means for the model
|
||||
|
||||
The usable analog range is 16–100 %, about 6:1, with the bottom sixth of the
|
||||
control range physically dead — and the factory's captured pulse files pin the
|
||||
power byte at 127 and modulate dose by dithering the FIRE bit at 6.5–18.8 %
|
||||
density. The dead band is why. `$35` is a patch that buys freedom from dropout
|
||||
by putting its full 16 % into every corner; dose set by pulse density cannot
|
||||
fall below the lasing threshold by construction. Item 17 is now the density
|
||||
model itself, with the analog path as the fallback.
|
||||
|
||||
## 2026-08-17 — how the factory sets power
|
||||
|
||||
Three cloud-mode cuts of the same 1" square, same location, same material,
|
||||
same speed, changing only the Glowforge UI power setting: Precision Power 1,
|
||||
Precision Power 100, then Full Power. Captures in
|
||||
`_RESOURCES/power-settings-20260817/`.
|
||||
|
||||
Pulse-file capture ships off (`LOGGING.SAVE_PULS`), and the machine's copy of
|
||||
`/data/etc/gfhome.conf` predated the key, so it was enabled for this session
|
||||
and turned off afterward. A first attempt appended the key past the last
|
||||
section, where `get_cfg('LOGGING.SAVE_PULS')` would never have found it — it
|
||||
belongs inside `[LOGGING]`, and was verified through the app's own parser
|
||||
rather than by eye.
|
||||
|
||||
### The measurement
|
||||
|
||||
**Analog duty is not a power control.** All three runs carry the power byte
|
||||
exactly three times, always 127: once as the cut begins, then a refresh every
|
||||
~27 000 ticks (~2.7 s). Nothing modulates PWMSAR, at any setting.
|
||||
|
||||
**Dose is FIRE-bit density on a fixed 7-tick period** — 700 µs at
|
||||
`STfr` = 10 000, ~1.43 kHz — with the on-count dithered between adjacent
|
||||
integers:
|
||||
|
||||
| Setting | on-runs | mean of 7 | density |
|
||||
|---|---|---|---|
|
||||
| Precision Power 1 | 1 (×359), 2 (×212) | 1.371 | 0.1953 |
|
||||
| Precision Power 100 | 5 (×236), 6 (×334) | 5.576 | 0.7952 |
|
||||
| Full Power | continuous | 7 | 0.9965 |
|
||||
|
||||
The period was exactly 7 in all 570 measured cycles of both dithered runs, and
|
||||
the mix of adjacent on-counts matches the fractional part exactly: PP 1 wants
|
||||
1.371 on-ticks, and 2-runs are 212 of 571 = 0.371. That is an error
|
||||
accumulator, not a repeating pattern.
|
||||
|
||||
**The power setting never reaches the machine.** The three headers are
|
||||
identical — no key differs — so the model lives entirely in the service, which
|
||||
bakes it into the FIRE bits. The motion is identical too: 5420 steps,
|
||||
101.62 mm (4 × 25.4), 10.81 s at 9.44 mm/s. Full Power's file is longer only
|
||||
in the lead-in before the cut.
|
||||
|
||||
**Velocity compensation is real but partial.** Density falls as the head slows
|
||||
into a corner, by the same relative factor at every power setting
|
||||
(corner/cruise 0.38, 0.38, 0.41). Measured per step interval, though, fire
|
||||
ticks per step *rise* from 3.89 at 9.44 mm/s to 7.00 at 1.22 mm/s, so dose per
|
||||
unit length still climbs ~1.8× at a corner — against the ~7.7× it would climb
|
||||
with no compensation at all. Only ~24 of 5420 step intervals are below cruise
|
||||
speed, so the direction and rough magnitude are solid and the exact law is
|
||||
not.
|
||||
|
||||
On the UI scale, PP 1→100 is linear in density (~0.006 per unit, intercept
|
||||
~0.189); Full Power sits off that line, where PP ~134 would land, which fits a
|
||||
setting the UI presents as outside the normal range.
|
||||
|
||||
### Two corrections to earlier readings
|
||||
|
||||
The first pass at the dither sampled the mid-point of the cut, which for a
|
||||
square is a corner, and truncated its distributions — it showed 8-on/4-off
|
||||
bursts that are corner behavior, not the steady pattern. The first pass at the
|
||||
dose law counted every tick as a step, because in this encoding bits 1 and 3
|
||||
are *direction*, held for the whole side, and only bits 0 and 2 are step
|
||||
pulses; the tell was 2026 mm of travel on a 101.62 mm cut.
|
||||
|
||||
### A defect found by using the feature
|
||||
|
||||
Deleting the capture directory under a running gfcloud showed that with
|
||||
capture enabled, a missing directory or a full disk makes `load_motion` raise
|
||||
on the capture write and kills the print. A debug aid must never cost a job:
|
||||
the capture open, the per-chunk write and the `.info` write are now each
|
||||
non-fatal, dropping the capture with a warning and running the job on
|
||||
(`gfutilities`, with a regression test in `tests/test_lifecycle.py`; verified
|
||||
in three cases — missing directory still loads the job, a writable directory
|
||||
still gets the copy, capture off writes nothing). No acceptance-catalog
|
||||
consequence: the path is an off-by-default debug capture with no bearing on
|
||||
emission, motion or the release surface.
|
||||
|
||||