Commission the laser duty floor; record how the factory sets power

The pthresh ladder on scrap puts the tube's two thresholds far apart: the
discharge strikes between 2 and 3 percent duty, but nothing lases usefully
below 16 percent (PWMSAR 20), and the rungs between show only a spot at
each line start. $35 ships at 16 (grblhal-glowforge 9466f76, pinned here).

The drill said current lift-off and first mark share a rung; this run
falsifies that, so its docstring and read-the-material text now name both
thresholds and warn that a start-of-line spot is below the threshold, not
at it.

A start-of-line spot is also what a full-power leak at a kernel run start
would look like, so laser_stream_test gains a ladder session (rule 10):
every FIRE tick must ride a commanded duty, and the fire ticks must divide
evenly across rungs. Both hold exactly - six commanded duties, no others,
and 28296 fire ticks on every rung - so the spots are the tube, not the
stream. The harness now derives its expectations from the floor, which
moves the M4 session's S500 plateau from 63 to 73.

laser.power-floor is a new auto acceptance test, the suite's only
non-firing one: a machine must actually carry the commissioned floor,
since stored settings beat freshly baked defaults.

Three cloud cuts of one square at Precision Power 1, 100 and Full Power
show what the analog path is competing with: the power byte is pinned at
127 in all three, dose is FIRE-bit density on a fixed 7-tick period with
the on-count dithered between adjacent integers, and the power setting
never reaches the machine at all. Facts bank and item 17 carry the
numbers; CAMPAIGN-LOG carries both sessions.
This commit is contained in:
ScottW514
2026-08-17 19:45:19 -04:00
parent 76d43686d0
commit cb41a6030c
6 changed files with 405 additions and 44 deletions
+176
View File
@@ -2599,6 +2599,182 @@ binned modes, 4.1× and 16.4× fewer bytes, which shortens the stall rather
than merely spacing stalls out) and the churn re-base (which is what
would allow a lead beyond 10 ms). Tracked in BRINGUP "Next work" item 16.
## 2026-08-17 — the laser duty threshold ladder
The first owed step of "Next work" item 17: measure where the tube starts
lasing, so `$35` can stop M4's velocity-scaled power falling below it.
### The run
`live_fire_drills.py pthresh 1000 300` on wood scrap, operator-run on dev
image `20260817220126`, machine idle and homed, coolant 23.9/24.1 °C. The
precondition was read off the machine first: `$30`=1000, `$31`=0, `$32`=1,
**`$35`=0.0**, `$36`=100 — no floor in place to lift the rungs.
Thirteen rungs, 2 %…30 % of full, 25 mm each at F300, constant power (M3),
3 mm of `+Y` between them. Before firing, the two conversions were checked
against each other: a rung of *P* % sends `S = 10·P`, which the core maps to
`floor(127·P/100)` counts, and `$35 = P` computes `min_value =
(uint)(127·P/100)` — the same integer, so the rung's percent *is* the `$35`
value exactly, not approximately.
### What came back
Material, counting from the first rung drawn: rung 1 (2 %) nothing at all;
rungs 2–9 (3–14 %) a tiny spot at the start of each line and a dark line
after it; rungs 10–13 (16–30 %) continuous marks.
The `hv_current` trace agrees independently. It holds 0 for 19.5 s (arm
wait), then runs nonzero to 82.8 s, immediately before Idle. Within it the
laser-off `G0` between rungs reads 0, so the current runs count the rungs:
**12 segments of ~4.7 s at a ~5.27 s period, not 13.** The last segment ends
at the job end, so it is rung 13; counting back 12 puts the first current at
rung 2. Rung 1 drew no measurable discharge current — the same rung that
left no mark, from a completely separate witness.
So the tube has **two thresholds, far apart**:
| | rung | duty | witness |
|---|---|---|---|
| Discharge strikes | 2 (3 %) | PWMSAR 3 | current lifts off; spot only |
| Sustained lasing | 10 (16 %) | PWMSAR 20 | first continuous mark |
Between them, 3–14 % is a **dead band**: current flows and climbs (per-rung
means 133 → 289 raw) with essentially no light out. Each line's opening spot
is the strike transient; the tube lights, drops below lasing gain, and coasts
dark for the remaining 25 mm.
This falsifies the drill's own guidance, which said the current "lifts off
baseline at the same rung the material starts marking" — lift-off is rung 2,
marking is rung 10. The docstring and the printed read-the-material text were
corrected to name both thresholds and to tell the operator that a rung
showing only a start-of-line spot is *below* the threshold, not at it.
Raw `hv_current` is a presence/absence witness only. Per-rung means are
non-monotonic at the top (429 at 20 %, then 311 and 302) and the variance
collapses on the top two rungs, which is what an aliased point-sample of a
pulsed current looks like; the signal has no characterized transfer function.
### Ruling out the firmware explanation for the spots
A start-of-line spot is also what a full-power leak would look like: a kernel
run start resets the hardware duty to ~100 %, so a fire bit reaching the
stream ahead of its power byte would burn at full power. The material already
argued against it — rung 1 is the first fire of the run, the likeliest place
for such a leak, and it is blank — but the stream is the record, so
`laser_stream_test.py` gained a fourth session (rule 10): a ladder in the same
shape, full power deliberately absent, asserting that every FIRE tick rides a
commanded duty and that the fire ticks divide evenly across rungs (a rung
opening at its neighbor's duty shows up as a surplus on one and a deficit on
the next).
Result on the native build: duties under FIRE were exactly `[22, 23, 26, 32,
41, 52]`, nothing else, and **28296 fire ticks on every rung, identical to the
tick**. No full-power window, no stale-duty window. The spots are the tube and
supply, not the firmware.
### What landed
- `DEFAULT_SPINDLE_PWM_MIN_VALUE 16.0f` in `boards/glowforge.h` — the
measured lasing rung. Chosen over the next rung up (20 %) because the floor
is spent at corners, where velocity and dose per unit length already move
the wrong way, and because `$35` is a user setting anyone can raise.
- The harness now derives its expectations from that floor (`duty_for()`), so
the M4 session's S500 plateau moved 63 → 73 and its ramp `[44, 52, 63, 127]`
→ `[57, 64, 73, 127]`, plus a new check that no duty under FIRE falls below
the floor. All four sessions pass, as do `switch_map_test`, `laser_arm_test`
and `laser_lifecycle_test`.
- `laser.power-floor`, an auto acceptance test (the suite's only non-firing
one): reads `$$` and checks the machine actually carries the commissioned
floor, since stored settings beat freshly baked defaults and a machine with
an older EEPROM needs `$RST=$` once. Coverage lint clean at 40 tests.
### What it means for the model
The usable analog range is 16–100 %, about 6:1, with the bottom sixth of the
control range physically dead — and the factory's captured pulse files pin the
power byte at 127 and modulate dose by dithering the FIRE bit at 6.5–18.8 %
density. The dead band is why. `$35` is a patch that buys freedom from dropout
by putting its full 16 % into every corner; dose set by pulse density cannot
fall below the lasing threshold by construction. Item 17 is now the density
model itself, with the analog path as the fallback.
## 2026-08-17 — how the factory sets power
Three cloud-mode cuts of the same 1" square, same location, same material,
same speed, changing only the Glowforge UI power setting: Precision Power 1,
Precision Power 100, then Full Power. Captures in
`_RESOURCES/power-settings-20260817/`.
Pulse-file capture ships off (`LOGGING.SAVE_PULS`), and the machine's copy of
`/data/etc/gfhome.conf` predated the key, so it was enabled for this session
and turned off afterward. A first attempt appended the key past the last
section, where `get_cfg('LOGGING.SAVE_PULS')` would never have found it — it
belongs inside `[LOGGING]`, and was verified through the app's own parser
rather than by eye.
### The measurement
**Analog duty is not a power control.** All three runs carry the power byte
exactly three times, always 127: once as the cut begins, then a refresh every
~27 000 ticks (~2.7 s). Nothing modulates PWMSAR, at any setting.
**Dose is FIRE-bit density on a fixed 7-tick period** — 700 µs at
`STfr` = 10 000, ~1.43 kHz — with the on-count dithered between adjacent
integers:
| Setting | on-runs | mean of 7 | density |
|---|---|---|---|
| Precision Power 1 | 1 (×359), 2 (×212) | 1.371 | 0.1953 |
| Precision Power 100 | 5 (×236), 6 (×334) | 5.576 | 0.7952 |
| Full Power | continuous | 7 | 0.9965 |
The period was exactly 7 in all 570 measured cycles of both dithered runs, and
the mix of adjacent on-counts matches the fractional part exactly: PP 1 wants
1.371 on-ticks, and 2-runs are 212 of 571 = 0.371. That is an error
accumulator, not a repeating pattern.
**The power setting never reaches the machine.** The three headers are
identical — no key differs — so the model lives entirely in the service, which
bakes it into the FIRE bits. The motion is identical too: 5420 steps,
101.62 mm (4 × 25.4), 10.81 s at 9.44 mm/s. Full Power's file is longer only
in the lead-in before the cut.
**Velocity compensation is real but partial.** Density falls as the head slows
into a corner, by the same relative factor at every power setting
(corner/cruise 0.38, 0.38, 0.41). Measured per step interval, though, fire
ticks per step *rise* from 3.89 at 9.44 mm/s to 7.00 at 1.22 mm/s, so dose per
unit length still climbs ~1.8× at a corner — against the ~7.7× it would climb
with no compensation at all. Only ~24 of 5420 step intervals are below cruise
speed, so the direction and rough magnitude are solid and the exact law is
not.
On the UI scale, PP 1→100 is linear in density (~0.006 per unit, intercept
~0.189); Full Power sits off that line, where PP ~134 would land, which fits a
setting the UI presents as outside the normal range.
### Two corrections to earlier readings
The first pass at the dither sampled the mid-point of the cut, which for a
square is a corner, and truncated its distributions — it showed 8-on/4-off
bursts that are corner behavior, not the steady pattern. The first pass at the
dose law counted every tick as a step, because in this encoding bits 1 and 3
are *direction*, held for the whole side, and only bits 0 and 2 are step
pulses; the tell was 2026 mm of travel on a 101.62 mm cut.
### A defect found by using the feature
Deleting the capture directory under a running gfcloud showed that with
capture enabled, a missing directory or a full disk makes `load_motion` raise
on the capture write and kills the print. A debug aid must never cost a job:
the capture open, the per-chunk write and the `.info` write are now each
non-fatal, dropping the capture with a warning and running the job on
(`gfutilities`, with a regression test in `tests/test_lifecycle.py`; verified
in three cases — missing directory still loads the job, a writable directory
still gets the copy, capture off writes nothing). No acceptance-catalog
consequence: the path is an off-by-default debug capture with no bearing on
emission, motion or the release surface.