diff --git a/docs/BRINGUP.md b/docs/BRINGUP.md index 3cded39..217c901 100644 --- a/docs/BRINGUP.md +++ b/docs/BRINGUP.md @@ -30,6 +30,16 @@ deadman/safety loop; camera error paths). counters agree step-for-step. Motion-only: the laser latch is forced locked, byte bit 4 is never emitted. +**First real LightBurn job: 2026-08-02, operator-verified.** Device +setup per `LIGHTBURN.md` (GRBL over TCP:23); a full design job — rapid +in, M4 dynamic-power cut trace at commanded speed, return rapid — ran +smoothly end to end on grblHAL-glowforge (laser locked, motion only). +Two driver fixes came out of the first attempts: the locked laser +spindle (M4/$32 support without fire capability) and the +continuation-wakeup cursor alignment (back-to-back cycles previously +clamped into step bursts — jerky, step-losing rapids; found via the +per-run `clamped` stat from the operator's own job log). + **Milestone 2 (motion quality): bench-verified 2026-08-02.** The factory motion constants were extracted from the `_RESOURCES` pulse files (`scripts/bench/puls_profile.py`) and applied end-to-end: