docs: the runbook's settings inventory and the bench page's help links are current

BRINGUP named nine cool_* tunables (there are thirty), a cool_fire_ir_delta
key nothing reads, and panel source files that no longer exist; the
inventory is the present one. The bench page's help popovers pointed at a
documentation host and paths that do not exist; they open the site.
This commit is contained in:
ScottW514
2026-09-02 08:15:12 -04:00
parent d9a0990510
commit b132965e15
2 changed files with 20 additions and 13 deletions
+14 -7
View File
@@ -440,7 +440,7 @@ One ulfius daemon serves it all:
- `GET /` — the tabbed control panel (**Status / Machine / GF Cloud / GRBL /
Diagnostics / Logs / System**; sources in `forgectrl/src/ui/`,
`index.html` + `panel.css` + `panel.js`, bundled into the binary by
`index.html`, `panel.js`, `forms.js`, `help.js` and `theme.css`, bundled into the binary by
`embed.cmake`; `tools/devserver.py` and the repo's `.devcontainer/` serve the
same panel on a workstation against a live board or a mock). Status carries
the controller-mode selector, the operational dashboard, a scaled lid
@@ -461,11 +461,10 @@ One ulfius daemon serves it all:
and 409 while a diagnostic owns the hardware; a multi-key POST lands as one
atomic replace. Keys: `controller_mode`, `homing_mode`, `gfcloud_home_x/y/z`,
`gfcloud_home_timeout_s`, `gf_serial`, `gf_password`, `ui_units`,
`wifi_country`, the nine `cool_*` tunables, `laser_button_timeout_s`,
`wifi_country`, the thirty `cool_*` tunables, `laser_button_timeout_s`,
`laser_disarm_s`, `rail_settle_s`, `lid_lamp_idle`, `lid_policy`,
`cloud_pause_backtrack_ticks`, `cloud_resume_lead_ticks`, the twelve
`cloud_pause_backtrack_ticks`, `cloud_resume_lead_ticks`, `cloud_hold_max_s`, the twelve
`log_<logger>_disk|_remote` levels and `syslog_server|port|proto`.
`cool_fire_ir_delta` is a hand-edited conf key, not a panel setting.
- `GET /mode`, `POST /mode?controller=grbl|cloud` — the supervisor: current
mode, controller state (`running | stopped | standby | motion-fault`), pid,
and the motion-liveness verdict (`verified | unverified | fault`); the POST is
@@ -592,9 +591,17 @@ hard-abort at 48 °C downstream:
gates between; reports both bands and recommends threshold = (flow max +
no-flow min)/2 with an Apply button, or refuses when the gap is under 3 °C.
**Cooling tunables are conf-backed**: the nine `cool_*` keys (`flow_rise`,
`flow_heater_pct`, `flow_check_s`, `recheck_s`, `confirm_max_s`, `temp_max`,
`temp_resume`, `cooldown_s`, `cooldown_max_s`) live in `/data/forgefirm.conf`
**Cooling tunables are conf-backed**: the thirty `cool_*` keys (the flow
check: `flow_rise`, `flow_heater_pct`, `flow_check_s`, `recheck_s`,
`confirm_max_s`, `laser_heat_cw`, `laser_heat_density`, `aa_offset_counts`;
the temperatures: `temp_max`, `temp_resume`, `temp_critical_c`, `temp_min`,
`temp_start`; the TEC: `tec_present`, `tec_on_c`, `tec_off_c`; the fire
watch: `fire_q1_alert`, `fire_q1_critical`, `fire_q2_alert`,
`fire_q2_critical`; the crash watch: `accel_x_alert`, `accel_y_alert`,
`accel_abort`; the cooldown: `cooldown_s`, `cooldown_max_s`; the airflow
gates: `tach_exhaust_min_rpm`, `tach_intake_min_rpm`,
`tach_air_assist_min_rpm`, `purge_min_current`, `fan_grace_s`) live in
`/data/forgefirm.conf`
(Machine tab, validated ranges), and the cooling engine re-reads them at **every
run start** (env `GFCOOL_*` > conf > compiled default; env stays the bench
override and wins for the process lifetime).