bench+docs: flow suspicion drills, coolant-flow triage record
flow_confirm_drill.py walks the driver's suspicion/confirmation state machine through every verdict with real pump-off transients in one M8 session; flow_escalate_drill.py exercises the starved-re-check escalation against a short GFCOOL_CONFIRM_MAX_S. BRINGUP records the triage resolution (the 2026-08-03 faults were a real transient stagnation, probable pump airlock - the check was right), the slug/ circulation measurements, and the new check semantics.
This commit is contained in:
+168
-11
@@ -86,10 +86,13 @@ motion constants were extracted from the `_RESOURCES` pulse files
|
||||
(`forgefirm-image-dev`) on SD; BusyBox userland + python3 + gdb/strace.
|
||||
Serial console on ttymxc0 available at the bench.
|
||||
- **Deploying kernels**: re-burn the SD with the freshly built
|
||||
`forgefirm-image-dev-glowforge.rootfs.wic.gz` (deploy dir below). Where
|
||||
the boot flow loads the kernel from was never fully traced (the wic has
|
||||
no boot partition; the eMMC env area reads empty) — re-burning works and
|
||||
is the procedure. **Module-only changes hot-swap**: scp `glowforge.ko`
|
||||
`forgefirm-image-dev-glowforge.rootfs.wic.gz` (deploy dir below).
|
||||
Why this works: U-Boot (in eMMC boot0) reads the saved env at eMMC
|
||||
user-area 0x80000, which selects the boot device (bench board:
|
||||
`mmcdev=0 mmcroot=/dev/mmcblk1p1` = SD), then loads `/boot/uEnv.txt`
|
||||
and `/boot/zImage` from that rootfs partition — so the kernel always
|
||||
comes from the burned SD. Full map: "eMMC boot & recovery
|
||||
architecture" in the facts bank below. **Module-only changes hot-swap**: scp `glowforge.ko`
|
||||
over `/lib/modules/<kver>/extras/`, then `rmmod glowforge && modprobe
|
||||
glowforge`. NOTE: a module reload turns off the lid LED (relight via
|
||||
`/sys/class/leds/lid_led*/target`) and resets analog config (below).
|
||||
@@ -382,6 +385,59 @@ max. Images from 20260807204056 carry forgectrl at the bumped SRCREV
|
||||
- Machine identity from OCOTP nvmem: serial 00000000 → hostname XXX-XXX
|
||||
(matches the factory label).
|
||||
|
||||
### eMMC boot & recovery architecture (dumped from the bench board 2026-08-08)
|
||||
|
||||
- eMMC (`mmcblk2`): 3.6 GiB user area + two 16 MiB hardware boot
|
||||
partitions (`mmcblk2boot0/1`). Factory user-area MBR (per the factory
|
||||
`.fw` manifest): p1/p2 = 200 MiB rootfs A/B at blocks 8192/417792,
|
||||
p3 = `/data` from block 827392 to end of disk. (The bench board runs
|
||||
the legacy ForgeFIRM layout instead: p3 shrunk to ~1.9 GiB plus a
|
||||
1.3 GiB p4.)
|
||||
- **U-Boot lives in boot0** at 1 KiB (IMX IVT header), not in the user
|
||||
area — user-area block 2 reads blank on the bench board even though
|
||||
the `.fw` `complete` task writes a U-Boot copy there. Any boot0
|
||||
rewrite below 0xC0000 risks the bootloader.
|
||||
- **Saved env**: user area 0x80000 with redundant copy at 0x82000 (the
|
||||
area `ffboot`/`fw_setenv` targets; boot0's own 0x80000 region is
|
||||
zeros). Slot selection = `mmcdev`/`mmchwpart`/`mmcpart`/`mmcroot`;
|
||||
bench board reads `mmcdev=0 mmchwpart=0 mmcpart=1
|
||||
mmcroot=/dev/mmcblk1p1` (SD boot). Gap: `ffboot` sets three of the
|
||||
four but never `mmchwpart` — it relies on the saved 0.
|
||||
- **Default (compiled-in) env boots recovery**: `mmcdev=1 mmchwpart=1
|
||||
boot_recovery=yes` — a blank/corrupt env lands in recovery mode, not
|
||||
a brick. `bootcmd`: select mmc dev+hwpart → load+import
|
||||
`/boot/uEnv.txt` from the selected partition → if
|
||||
`boot_recovery=yes`, boot kernel+DTB from raw boot0 sectors, else
|
||||
load `/boot/zImage` from the slot's rootfs. U-Boot itself polls the
|
||||
button at power-on ("Recovery boot requested by user; release button
|
||||
to enter" / "Button held too long, booting normally"); it also has
|
||||
watchdog-timeout boot-flag strings (semantics untraced).
|
||||
- **boot0 map**: MBR / U-Boot @1 KiB / zeros @0x80000 / recovery DTB
|
||||
@0xC0000 (`fdt_dev_addr=0x600`, 64 KiB slot) / recovery zImage
|
||||
@0x100000 (`image_dev_addr=0x800`, 5 MiB slot, kernel 3.14.28) /
|
||||
recovery squashfs = `boot0p1` @6 MiB (10 MiB slot, 8.6 MiB used,
|
||||
built 2018-03-09).
|
||||
- **boot1 map**: MBR / squashfs @1 KiB = `boot1p1` (10.6 MiB used),
|
||||
mounted as the recovery `/usr` (python runtime) by
|
||||
`init.d/recovery-usr`.
|
||||
- **Recovery userspace** = the factory setup webapp (bottle): WiFi
|
||||
setup/AP, log export, `/version`, and `.fw` upload (→ tmpfs →
|
||||
`glowforge-updater -f` → fwup signature check against
|
||||
`/glowforge/pubkeys` → writes slot A → flips env). It is never
|
||||
updated in the field — `.fw` updates don't touch the boot
|
||||
partitions, so every machine still runs its as-manufactured
|
||||
recovery.
|
||||
- **Factory `.fw` format** = signed fwup 0.14.2 archive (ZIP:
|
||||
`meta.conf` + `meta.conf.ed25519` + payloads). Tasks: `complete`
|
||||
(MBR, U-Boot to user area, zero both env copies, rootfs → slot A,
|
||||
zero p2/p3 heads) and `upgrade.a`/`upgrade.b` (raw-write
|
||||
`rootfs.ext4` into a slot). Factory updater flow: authenticated
|
||||
`GET <server>/update/current` → `{version, download_url}` →
|
||||
resumable download to `/data/glowforge.fw` → verify → apply to the
|
||||
INACTIVE slot → `fw_setenv mmcpart mmcroot` → reboot. Factory
|
||||
`rootfs.ext4` is 65 MiB; the ForgeFIRM rootfs is ~141 MB used, so it
|
||||
fits a 200 MiB slot with headroom.
|
||||
|
||||
## Next work (in rough order)
|
||||
|
||||
1. **Backend milestone 2 — motion quality: DONE and human-verified
|
||||
@@ -526,13 +582,63 @@ max. Images from 20260807204056 carry forgectrl at the bumped SRCREV
|
||||
the dependence is weak — with forced flow ΔT = P/(ṁ·c), which
|
||||
carries no absolute-temperature term — but that is reasoning,
|
||||
not measurement.
|
||||
- **OBSERVED 2026-08-03 (needs triage):** `/data/glowforge.log`
|
||||
carries, from a prior controller run, a passing check (rise
|
||||
11.4 °C) followed by TWO `COOLANT FLOW FAULT` lines (rise
|
||||
16.5 / 15.9 °C vs the 14.4 limit, dT 11.6). Undated (raw
|
||||
stderr log). Either the pump genuinely faltered or this is the
|
||||
warm-baseline false-positive mode above — check the pump and
|
||||
re-run a supervised verification before trusting the loop.
|
||||
- **TRIAGE RESOLVED 2026-08-08 — the 2026-08-03 faults were a
|
||||
REAL transient stagnation, not false positives; loop trusted
|
||||
again.** The log lines (pass rise 11.4, then FAULT 16.5 / 15.9,
|
||||
dT 11.6) postdate the warm-baseline validation session:
|
||||
`flow_warm_validate.py`'s controller restart truncates
|
||||
`/data/glowforge.log` (single `>`), so they were written by a
|
||||
driver M8 session after 23:21 on 2026-08-02 — right after a
|
||||
bench session that stopped/started the pump 8+ times with
|
||||
~50 °C heater excursions (classic airlock conditions).
|
||||
Signature analysis against the design matrix: the fault rises
|
||||
sit at the characterized no-flow floor (16.04), and the
|
||||
establish-window dT 11.6 sits in the no-flow band (driver-
|
||||
equivalent dT-mean from the matrix: no-flow 11.9–13.2 vs flow
|
||||
9.8–10.2) — the checks correctly read stagnant/near-stagnant
|
||||
water at that moment. Probable cause: transient pump airlock
|
||||
from the bench session's pump cycling, self-cleared (the
|
||||
preceding 11.4 pass shows flow was fine minutes earlier).
|
||||
**Re-verified 2026-08-08 through the production path** (M8 on
|
||||
the flashed v0.1.0 image, pump operator-confirmed, 22 °C
|
||||
settled loop): rise 11.3 dT 9.5, and after an M9→M8
|
||||
layer-cycle, rise 10.8 dT 9.3 — textbook flow-band values.
|
||||
Also measured: **no recirculating heat slug** — each check's
|
||||
heat is fully shed within ~60 s (two checks left the loop
|
||||
0.4 °C net cooler), and fan-profile transitions inject brief
|
||||
~1.7 °C COLD slugs from the radiator (~20 s), showing the loop
|
||||
circulates in tens of seconds. Operational lesson: expect a
|
||||
possible legitimate flow SUSPECT on the first checks after
|
||||
manual pump stop/start cycling — the confirmation machinery
|
||||
below absorbs it.
|
||||
- **Suspicion/confirmation state machine — IMPLEMENTED
|
||||
2026-08-08, bench-drilled 6/6 + escalation** (driver
|
||||
`glowforge_cooling.c`). An over-limit check is a SUSPICION,
|
||||
not a fault: `COOLANT FLOW SUSPECT` warning + an immediate
|
||||
re-check request (no cadence wait). The next completed check
|
||||
decides it — "consecutive" means no clean check in between,
|
||||
whatever the wall-clock gap: over-limit again →
|
||||
`COOLANT FLOW FAULT`; clean → `coolant flow suspicion
|
||||
cleared`, episode counted (3 cleared episodes in one job earn
|
||||
an aggregated check-your-coolant warning; counter resets when
|
||||
cooldown reaches idle). A suspicion that cannot produce any
|
||||
verdict within `GFCOOL_CONFIRM_MAX_S` (default 480 s; budget
|
||||
restarts per flood session, runs only in Cool_Run) escalates
|
||||
to FAULT — a loop that will not settle after a fault-level
|
||||
reading has shown no evidence of health. A clean check from
|
||||
the FAULT state logs `coolant flow recovered`. Laser
|
||||
milestone: safe posture (hold + laser off + forced cooling)
|
||||
moves to the SUSPECT edge; FAULT stays the hard fire gate.
|
||||
Bench drill (`scripts/bench/flow_confirm_drill.py`, on-board,
|
||||
real pump-off transients through the production path, single
|
||||
M8 session): verified 11.6/9.4 → pump off SUSPECT 16.4/12.0 →
|
||||
pump on cleared 11.9/9.5 in 92 s (the 2026-08-03 field case,
|
||||
now non-fatal) → pump off SUSPECT 18.5 → still-off confirmed
|
||||
FAULT 16.1 just 109 s after the suspect → pump on recovered
|
||||
11.1/9.4. All six verdicts in order, 6/6. Escalation drilled
|
||||
separately (`flow_escalate_drill.py` with
|
||||
GFCOOL_CONFIRM_MAX_S=45): suspect → starved settle → "no
|
||||
clean re-check within 45 s" FAULT.
|
||||
|
||||
*(Superseded earlier text kept below for context.)*
|
||||
**Coolant flow verification (first attempt, live-verified both ways).**
|
||||
@@ -567,6 +673,57 @@ max. Images from 20260807204056 carry forgectrl at the bumped SRCREV
|
||||
there.
|
||||
- **Interlock readback semantics cross-check: OPEN** (see
|
||||
factory-laser-safety-readbacks notes).
|
||||
- **Head-IRQ source validation — beam-emission hypothesis: OPEN
|
||||
(exploratory feature; NOT a first-light prerequisite).** The
|
||||
EV_SW `head` bit (GPIO3_22, factory pad name HEAD_IRQ; the
|
||||
panel's "Head sense" row) is the head MCU's attention line —
|
||||
idle LOW with a healthy head attached (measured 2026-08-08); it
|
||||
pulses on head reboot (hence the 60 ms DT debounce) and floats
|
||||
to the SoC pull-up with no head driving it, so the raw level is
|
||||
NOT a presence signal (presence = the head answering at I²C
|
||||
0x47). The factory app answers this IRQ by reading the head's
|
||||
interrupt flags over I²C, and the only flag register is the reg
|
||||
0x05 RO group — bit0 hall_sensor, bit1 accel_irq, bit2
|
||||
beam_detect_digital (head_private.h) — so there are exactly
|
||||
three candidate IRQ sources; working hypothesis (operator): the
|
||||
in-cut source is the head's IR beam-emission detector — digital
|
||||
flag 0x05 b2 + analog level reg 0x16 (both already head sysfs
|
||||
attrs), tunable detection model at regs 0x22–0x2a
|
||||
(lambda_k/lambda_t/theta_r/theta_t/e_t = the factory
|
||||
BDlk/BDlt/BDtr/BDtt/BDet settings; regs defined in
|
||||
head_private.h, not yet exposed as attrs).
|
||||
Priority/scope (operator, 2026-08-08): later exploration, not a
|
||||
must-have —
|
||||
- The bench head is **gen2** (a first-round Kickstarter unit
|
||||
already shipped gen2). Gen1 heads are presumed rare to
|
||||
nonexistent in the wild, though the factory images still
|
||||
support them, so some must be assumed to exist. The gen1
|
||||
board-level beam chain (!BEAM_DET GPIO4_15, !BEAM_DET_XOR
|
||||
GPIO4_08, !BEAM_DET_TIMEOUT GPIO4_07, BEAM_DET_ERR GPIO4_10 —
|
||||
DT-pinmuxed, not driver-requested; BEAM_DET_LATCH_RST GPIO7_13
|
||||
pulsed at cut start, boards v13/v14 only) is documented here
|
||||
as legacy reference only.
|
||||
- Whether the factory actually USES beam detect is unknown. The
|
||||
v2.6.0 factory app carries a complete but config-gated
|
||||
subsystem (separate printing/idle enables, severities
|
||||
failing-abort / pausing-alert / silent-alert, level-vs-edge
|
||||
trigger option, beam_detect_irq + irq_override, fault report
|
||||
upload; an invalid severity defaults to DISABLED), so the
|
||||
plumbing exists but production enablement is an open question.
|
||||
Detection at low fire energies is also unverified — the sensor
|
||||
may simply not trip on a low-power pulse.
|
||||
- Same status for the accelerometer: a promo-touted factory
|
||||
feature that was not active in early releases and may not be
|
||||
today. Its data path is direct (lis2hh12 on the I²C bus) but
|
||||
its INT pin routes to the head MCU as flag 0x05 b1, so it is
|
||||
also a head-IRQ source.
|
||||
Cheap opportunistic check during live-fire bring-up (no gating):
|
||||
log EV_SW head-bit edges + head/beam_detect_digital/_analog
|
||||
while firing — if the beam flag level-holds the IRQ, the panel
|
||||
row asserts during sustained emission. Later-feature decisions
|
||||
if it pans out: beam-absent-while-FIRE as an optional fault
|
||||
input, attrs for the calibration regs, panel row relabel (e.g.
|
||||
"Head IRQ / emission").
|
||||
3. **Homing: runtime-selectable, Glowforge web-service mode
|
||||
IMPLEMENTED and bench-verified (stub session) 2026-08-07; LIVE
|
||||
cloud run still pending operator.** The operator picks the method
|
||||
|
||||
Reference in New Issue
Block a user