mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-27 16:51:12 -07:00
Fan floors from the measurement; a hunt is measured, not judged
forgectrl pin 47e4256: the airflow floors set from the bench measurement (exhaust 6400, intake 2290, air assist 6000 rpm, purge current 300, grace 15 s) and the operating-point rule: a fan is judged while the laser is armed, when a job's profile may raise it but never lower it below the run duty, or whenever it is commanded at the run duty; the service's hunts, sent with the extraction fans off, are measured and published unjudged. Catalog: cloud.mode-switch now waits out the connect-time hunt sampling /cool/status and requires no AIRFLOW, the exhaust row unjudged and the exhaust actually off; its covers gain forgectrl src/cool.* and src/airflow.*. cooling.fan-gate-trips uses an 8 s test grace (the intakes take 7 s to 90 percent and tripped under the old 2 s at the new floor) and its off leg waits for the row state as well as gates_off. fan_floor_measure.py names a reply that is not JSON and calls the purge readings idle and run (the pump is always on). Docs: COOLING 3a and the settings table, BRINGUP item 19 and a facts-bank entry with the measured fan speeds, the bench README, and a CAMPAIGN-LOG entry for the measurement, the two status-document finds, the hunt find and the hot-deployed bench runs of both tests.
This commit is contained in:
@@ -3254,6 +3254,60 @@ value), and the test quoted the session's first job-limits line, a hunt's,
|
||||
where the print's is the one worth keeping (it now takes the first line
|
||||
after the print's action request).
|
||||
|
||||
## 2026-08-22: the fan floors measured, and a hunt that would have tripped them
|
||||
|
||||
`fan_floor_measure.py spinup` (bench page `fan-floor`, 120 s at the cut
|
||||
profile from idle, GRBL mode, the exhaust duct's inline booster fan off, so
|
||||
the exhaust worked against more back pressure than a normal cut):
|
||||
|
||||
| fan | steady rpm | min | max | sd | t90 |
|
||||
|---|---|---|---|---|---|
|
||||
| exhaust | 11638 | 11444 | 11947 | 103 | 5 s |
|
||||
| intake 1 | 4157 | 4102 | 4193 | 12 | 7 s |
|
||||
| intake 2 | 4158 | 4128 | 4173 | 6 | 7 s |
|
||||
| air assist | 11048 | 11029 | 11061 | 8 | 1 s |
|
||||
|
||||
Purge current 627 at idle and 625 at run duty: the engine holds purge air on
|
||||
continuously, so both are the "on" reading (the off reading, ~1, is from an
|
||||
earlier observation). The floors shipped from this: exhaust 6400, intake
|
||||
2290, air assist 6000 rpm (55 percent of steady, bands 50 to 60 percent),
|
||||
purge current 300, grace 15 s (twice the slowest time to 90 percent). The
|
||||
provisional floors had come from a snapshot at a lower exhaust speed; the
|
||||
measured margin is larger.
|
||||
|
||||
The run also sent the first `/cool/status` with the limits and the fan rows
|
||||
through a 512-byte reply buffer, and then a 160-byte limits fragment: twice
|
||||
a cut-off document, found by the measurement tool refusing to parse it.
|
||||
Both fixed in forgectrl with a host test that renders the widest legal
|
||||
document and parses it (`tests/coolfmt_test.c`).
|
||||
|
||||
Reading the measurement through cloud mode found a defect in the gates as
|
||||
first built: the service reports every action as a run, and its hunt and
|
||||
motion headers command the exhaust and the intakes off and the air assist
|
||||
at idle, so a hunt longer than the grace would have tripped `AIRFLOW` at
|
||||
any floor. Decision (operator): a fan is judged only at the operating
|
||||
point its floor was measured at: always while the laser is armed, when a
|
||||
job's profile may raise a fan but never lower it below the run duty; and
|
||||
unarmed when commanded at the run duty. A hunt is measured, published as
|
||||
`unjudged`, and not judged. `cloud.mode-switch` now watches the connect-time
|
||||
hunt's gate rows for it.
|
||||
|
||||
Both tests ran the same day on a hot-deployed forgectrl (the working tree
|
||||
cross-built and installed over dev image `20260821230723`; informational,
|
||||
not acceptance). `cloud.mode-switch` PASS: the hunt reported two run ticks
|
||||
with the exhaust off and `unjudged`, verdict `OK` throughout.
|
||||
`cooling.fan-gate-trips` FAIL first, for two reasons worth keeping: the
|
||||
run-start tick resolved the effective limits before it reloaded the
|
||||
settings, so for one tick `gates_off` named the exhaust while its row still
|
||||
carried the old floor (fixed: the session start re-resolves the limits after
|
||||
the reload, so rows, `gates_off` and the log line agree); and the test's
|
||||
2 s grace, chosen against the provisional 1800 rpm intake floor, now let
|
||||
both intakes trip at ~1850 rpm on their 7 s spin-up (the test grace is 8 s).
|
||||
Rerun PASS in 59 s: only the exhaust tripped in the exhaust leg, only the
|
||||
purge in the purge leg, the exhaust read `off` with floor 0 in the off leg,
|
||||
and the restore showed every fan `ok` at the shipped floors (exhaust 11723,
|
||||
intakes 4157 and 4162, air assist 11078 rpm, purge 628 counts).
|
||||
|
||||
## Superseded status notes
|
||||
|
||||
### Shared machine services — remaining polish, as listed 2026-08-13
|
||||
|
||||
Reference in New Issue
Block a user