Fan floors from the measurement; a hunt is measured, not judged
forgectrl pin 47e4256: the airflow floors set from the bench measurement (exhaust 6400, intake 2290, air assist 6000 rpm, purge current 300, grace 15 s) and the operating-point rule: a fan is judged while the laser is armed, when a job's profile may raise it but never lower it below the run duty, or whenever it is commanded at the run duty; the service's hunts, sent with the extraction fans off, are measured and published unjudged. Catalog: cloud.mode-switch now waits out the connect-time hunt sampling /cool/status and requires no AIRFLOW, the exhaust row unjudged and the exhaust actually off; its covers gain forgectrl src/cool.* and src/airflow.*. cooling.fan-gate-trips uses an 8 s test grace (the intakes take 7 s to 90 percent and tripped under the old 2 s at the new floor) and its off leg waits for the row state as well as gates_off. fan_floor_measure.py names a reply that is not JSON and calls the purge readings idle and run (the pump is always on). Docs: COOLING 3a and the settings table, BRINGUP item 19 and a facts-bank entry with the measured fan speeds, the bench README, and a CAMPAIGN-LOG entry for the measurement, the two status-document finds, the hunt find and the hot-deployed bench runs of both tests.
This commit is contained in:
+24
-7
@@ -623,6 +623,18 @@ until `releases/v<version>/acceptance.json` is committed.
|
||||
|
||||
## Hardware facts bank (measured)
|
||||
|
||||
- **Fan speeds at the cut profile** (exhaust duty 65535, intake 43278, air
|
||||
assist 1023; sampled at 1 Hz over 120 s from idle, the exhaust duct's
|
||||
inline booster fan off): exhaust **11640 rpm** steady (spread 11444 to
|
||||
11947, 90 percent of steady in 5 s), intakes **4157 / 4158 rpm** (spread
|
||||
under 100, 7 s), air assist **11050 rpm** (spread 30, 1 s); at idle the
|
||||
exhaust and intakes read 0 / ~745 rpm and the air assist ~1900 rpm
|
||||
(idle duty 204). The purge-air fan is always on and reads **~625 counts**
|
||||
of `head/purge_air_current` (~1 when off). The airflow floors are 55
|
||||
percent of these (bands 50 to 60 percent); an inline booster fan changes
|
||||
the exhaust's back pressure and can move its reading by a few percent
|
||||
either way, well inside the margin.
|
||||
|
||||
- **DRV8825 stepper drivers wedge on 40 V rail glitches** (factory board; the
|
||||
TMC2130s belong to the upgraded OpenGlow board only). A glitch can leave the
|
||||
drivers unserviceable: SDMA playback and the position counters run normally
|
||||
@@ -1340,13 +1352,18 @@ Open items only. Anything closed is in `CAMPAIGN-LOG.md`.
|
||||
while the run profile is applied (exhaust, intakes and air assist by
|
||||
tachometer, purge by current), a spin-up grace, three ticks under the
|
||||
floor, a fault for the rest of the session (`AIRFLOW`, no resume), a
|
||||
header window only ever raising a floor; `cooling.fan-gate-trips` in
|
||||
the catalog. The shipped floors are provisional, 55 percent of one
|
||||
run-duty snapshot (exhaust 3700, intake 1800, air assist 6000 rpm,
|
||||
purge current 300, grace 15 s) until `fan_floor_measure.py` has been
|
||||
run on the bench and the numbers in `forgectrl/src/gates.c` set from
|
||||
it. The coolant critical tier and the watch-only board temperatures
|
||||
follow.
|
||||
header window only ever raising a floor. A fan is judged at the
|
||||
operating point its floor was measured at: always while armed (when a
|
||||
job's profile may raise a fan but never lower it below the run duty),
|
||||
and unarmed whenever it is commanded at the run duty; a cloud hunt,
|
||||
sent with the extraction fans off, is measured and not judged.
|
||||
`cooling.fan-gate-trips` and the hunt leg of `cloud.mode-switch` in
|
||||
the catalog. The shipped floors are 55 percent of the bench machine's
|
||||
measured steady speeds (facts bank: exhaust 6400, intake 2290, air
|
||||
assist 6000 rpm, purge current 300, grace 15 s); the bench run of the
|
||||
gate tests on an image carrying them, and the unplugged-tach drill,
|
||||
are still owed. The coolant critical tier and the watch-only board
|
||||
temperatures follow.
|
||||
|
||||
Nothing here can put energy where it was not commanded: the hardware chain
|
||||
is the emission boundary and no header field touches it, and forgectrl runs
|
||||
|
||||