Cover the minimum pulse width; record what the density ladders measured

Rule 15 in the stream harness holds both halves of the minimum
(grblHAL-glowforge f7e8c17, pinned here): no emitted burst falls below
laser_pulse_min_ticks, excepting one clipped by fire going off mid-burst,
and the levels too faint to fill a window still render their exact
average density. Checked against a run at minimum 1 so it cannot pass
vacuously - level 2 goes from 444 bursts of one tick to 147 of three at
the same density, and levels already above the minimum are unchanged.

Four bench ladders settle the base period at 20. The same six rungs
marked in all of them, and the matched pairs across periods separate the
variables: at identical pulse length, halving the density killed the
mark; at identical density, varying the pulse 3x changed nothing. Feed
does not move it either - 10 percent at F100 carries 44 percent more
energy per mm than 20 percent at F300, which marks, and still left
nothing. The low-end marking limit is average power, not dose per length
and not pulse length.

The F100 trace separates two failures that look alike on the material:
seven current segments for eight rungs, anchored by a flat saturated
final segment that can only be full density, put 5 percent at no
discharge at all and 10 percent at a full 15 seconds of current with no
mark. Only the first is ours, and the minimum pulse is the answer to it.

Also recorded: the factory's Precision Power 1 runs a 19.53 percent FIRE
duty cycle at full PWM duty, and its 1-100 scale maps onto density
18.9-79.5 percent, so its 1 percent is the bottom of the useful band
rather than 1 percent of the range. Under the density model $35 and $36
are that same control - a density floor and ceiling - which makes the
user-facing scale a settings choice rather than new code.
This commit is contained in:
ScottW514
2026-08-17 21:37:41 -04:00
parent b7091effb7
commit a3e83c4fd5
4 changed files with 165 additions and 14 deletions
+94
View File
@@ -2860,6 +2860,100 @@ show each level firing its own move. It does — 28338 fire ticks each at
duties 30, 52 and 84, where before the fix duty 30 held all 85014 and the
two other levels never appeared.
## 2026-08-17 — the density ladders, and the minimum pulse
Four live ladders on one piece of scrap, 8 rungs each from 5 % to 100 % of
dose at constant power: base period 20, 40 and 10 ticks at F300, then period
20 again at F100. The same six rungs marked every time — 20 % and up. 5 % and
10 % never marked in any of the four.
### Pulse length is not the variable; average power is
Because the same pulse length occurs at different densities across the
periods, the runs contain matched pairs:
| pulse | density | period | marked |
|---|---|---|---|
| 107–142 µs | 20 % | 20 | yes |
| 107–142 µs | 10 % | 40 | no |
| 36–71 µs | 20 % | 10 | yes |
| 36–71 µs | 10 % | 20 | no |
Hold the pulse and halve the density: the mark goes. Hold the density and
vary the pulse 3×: nothing changes. Feed does not move it either — 10 % at
F100 carries 0.0567 dose/mm against 20 % at F300's 0.0394, **44 % more energy
per millimeter than a rung that marks**, and it still left nothing. Two
independent variables moved without shifting the boundary. What sets the
low-end marking limit is average power reaching a quasi-steady surface
temperature; going slower does not help, because the heat conducts away
between pulses.
So the base period can be chosen on other grounds, and stays at 20.
### The trace separates two different failures
The F100 run carried the `hv_current` trace (`pthresh` printed one, `dladder`
did not until this run — the omission cost the three F300 ladders their
per-rung witness). It shows **seven** current segments for eight rungs:
boundaries at 36.6, ~52.0, 67.3, 82.5, 98.0 and 113.2 s, each segment
14.4–14.9 s, one 25 mm rung at F100. The fire window is 106.8 s where eight
rungs would need 121.6 s.
The final segment anchors the count: 113.5–128.4 s reads 943–986 dead flat,
the saturated steady current of continuous fire, which can only be 100 %.
Counting back, the segment means rise monotonically — 182, 320, 330, 390,
450, 540, 967 — for rungs 10 % through 100 %. Rung 1 has no segment at all:
its fifteen seconds are the zeros before 21.6 s, indistinguishable from the
arm wait because nothing happened in them.
| rung | outcome |
|---|---|
| 5 % | **no discharge at all** |
| 10 % | discharge for the full 15 s, no mark |
| 20 %+ | discharge and mark |
Supply current is not light — `pthresh` already showed this tube drawing
current across a whole band while emitting nothing — so "10 % struck" is not
"10 % lased". But 5 % not striking is unambiguous, and it is ours to fix.
### The factory's own numbers, for scale
Precision Power 1 runs the power byte at 127 (PWM duty 100 %) and a **FIRE
duty cycle of 19.53 %** — 1.371 on-ticks of every 7-tick window. Fitting the
three captures, the factory maps its entire 1–100 scale onto density
18.9–79.5 %, with Full Power off that line at ~99.7 %. Its "1 %" is the
bottom of the band that does useful work, not 1 % of the physical range —
which is why no user ever meets the dead zone. The older `_RESOURCES`
captures run 6.5–18.8 % density on other jobs, so 18.9 % is a product
decision about cutting, not a physical floor.
### The fix: a minimum pulse width
At 5 % the model emitted one-tick stubs, 36 µs, and the supply did not
strike. The factory never emits below one 100 us tick and reaches low density
by skipping windows instead. `laser_pulse_min_ticks` (default 3 = 106 µs)
does the same: when the computed on-count falls below the minimum the period
is skipped and the **whole** debt carried, rather than a stub emitted. The
debt is conserved, so the average density is untouched.
Measured on the stream, level 2 (density 0.0159):
| | bursts | density |
|---|---|---|
| minimum 1 tick | 444 × 36 µs | 0.0158 |
| minimum 3 ticks | **147 × 106 µs** | 0.0159 |
147 × 3 = 441 against 444 — the same energy as fewer, longer pulses, and
every level already above the minimum is bit-identical, so the change touches
only what it must. Rule 15 in the stream harness holds both halves: no burst
below the minimum (excepting one clipped by fire going off mid-burst), and
the rendered density still exact.
Owed next: the user-facing scale. Under this model `$35` and `$36` are a
density floor and ceiling, so mapping S onto the usable band is a settings
choice rather than new code — but the floor's value wants a finer ladder than
the 10 %→20 % step these four runs give.
## Superseded status notes
### Shared machine services — remaining polish, as listed 2026-08-13