The critical tier proven on a rising loop; the board temperatures watched
forgectrl pin 76115fd: the chassis LM75 and the supply sensor ride /status as temps (degrees and a raw count), the engine ranges them over every run session into one run-end line, and a critical fault that clears with its session yields the reason to the standing hold. Bench: critical_tier_drill.py (a bench tool now, registered as critical-tier) sets the ceiling, the resume gate and the critical line a few tenths above the live upstream reading and lets the engine's own flow-check heater warm the loop through them inside one M8 session; temp_calibrate.py gains supply-watch, supply-point and supply-fit for the supply sensor against a thermometer on its heatsink, the fit shown beside UAPI.md's unverified guess. Catalog: cooling.gate-off checks the /status temps fields and the run-end board-temperature line (the unit fake mirrors both, one new failure case); cooling.critical-tier checks the reason after a faulted session. Docs: CAMPAIGN-LOG entries for cooling.critical-tier on dev image 20260822154257 and the warm-loop drill (OVERTEMP at 10 s, CRITICAL at 14 s, the fault ending with the session); BRINGUP item 19, the facts bank (board temperatures at idle), COOLING section 9, the bench README.
This commit is contained in:
@@ -40,6 +40,8 @@ page's takeover does that; from a host, stop them first.
|
||||
| `flow_characterize.py` | Coolant flow characterization using the factory temperature curve (board or host; forgectrl and controller stopped): baseline → flow → no-flow → recovery, printing the ΔT bands and their separation. Takes the heater duty as an argument (`flow_characterize.py 30`); aborts if downstream passes 45 °C. |
|
||||
| `flow_matrix.py` | **The flow-detection design matrix** (board or host; forgectrl and controller stopped; with `flow_sampler.py` from `/usr/share/forgetest/bench/`): duty × duration × flow/no-flow, every run from a common cooled baseline, interleaved repeats. One heating trace yields the metric at every candidate duration, so cost and precision come from the same 60 runs. Prints a cost table, a precision table (mean±sd, worst-case margin, d′) and a ranked shortlist. `flow_matrix.py [duties] [repeats]` (or env `FM_DUTIES`, `FM_REPEATS`, `FM_RESULTS`); results/log in the bench data directory, resumable. |
|
||||
| `flow_sustained.py` | Long-run test of the real re-check cadence via M8 (board or host; controller running): counts verdicts/false faults against the configured `cool_flow_rise` and tracks whether the loop accumulates heat. `flow_sustained.py [minutes]`. |
|
||||
| `temp_calibrate.py` (`supply-*` modes) | The power supply's sensor (`pic/pwr_temp`, raw) against a thermometer on its heatsink: `supply-watch`, `supply-point <C>`, `supply-fit`; the fit is printed beside `UAPI.md`'s unverified guess. Three points during a long cut settle it. |
|
||||
| `critical_tier_drill.py` | The coolant critical tier on a rising temperature (board or host): sets the ceiling, the resume gate and the critical line a few tenths above the live upstream reading and lets the engine's own flow-check heater warm the loop through them inside one `M8` session, expecting `OVERTEMP` at the ceiling and then `CRITICAL` (fire blocked, hold, no resume) with the fault ending at `M9`; restores the settings and cycles a session so the engine re-reads them. Results as JSON in the bench data directory. |
|
||||
| `flow_warm_validate.py` | Runs the real check from a heater-warmed baseline (board or host; forgectrl and controller stopped; `flow_warm_validate.py [cycles_per_case]`; results/log in the bench data directory; exit 1 if any run is misclassified). Note the ceiling: 100 % duty pushes the downstream sensor past 50 °C in 30 s while the bulk barely moves, so warm-loop validation above ~23 °C needs the laser, not the heater. |
|
||||
| `flow_recheck_char.py` | Characterizes short in-run re-checks and the differential metric (board or host; forgectrl and controller stopped; `flow_recheck_char.py [heater_pct] [window_s]`); shows why over-temp cannot see a stopped pump and why passive warming trends are ambiguous. |
|
||||
| `flow_confirm_drill.py` | Coolant flow suspicion/confirmation drill (runs on the board): one continuous M8 session walks the verdict state machine through real pump-off transients — verified → SUSPECT (+ immediate re-check) → cleared → SUSPECT → FAULT (consecutive) → recovered — printing PASS/FAIL per transition. Leaves the machine idle (M9, pump on, heater off). |
|
||||
|
||||