Add the sender-change and RX-overrun harness scenarios and the day's records
laser_lifecycle_test.py gains sender-change-mid-job (a laser-on against a window closed while the spindle was on must prompt again) and rx-overrun (a job written past the RX ring is reported, stopped in alarm with the window closed, and a clean job arms after it). The flowload drill's verdict parser accepts the engine's laser-share suffix. BRINGUP: item 20 holds only the owed work; item 21 opens the mid-job sender-change discussion with the Grbl expectation; item 22 is the flow check under a lit tube; item 23 is the power-good line's meaning. CAMPAIGN-LOG records the driver fix and the flow-check reading, both host-proven. No catalog consequence: harness scenarios and documentation; no runtime behavior of the release image changes in this commit.
This commit is contained in:
+58
-7
@@ -1447,13 +1447,64 @@ Open items only. Anything closed is in `CAMPAIGN-LOG.md`.
|
||||
overflowed, and the serial layer drops bytes on a full ring (`serial.c`,
|
||||
the overflow flag is set and never read), so the job's M5 and M2 were
|
||||
lost, the window stayed open until the sender disconnected, and the
|
||||
following job ran unarmed. Fix, in this order: arm on
|
||||
`state.on && !laser_ok` (the consent question does not depend on the
|
||||
previous spindle state); clear the spindle state in `gflaser_disarm`;
|
||||
consume the RX overflow flag (report the error and drop the client, so
|
||||
a sender that ignores flow control cannot leave a half job behind).
|
||||
Each part gets a regression test in the null-sink harness with the fix,
|
||||
and the catalog's `covers` widens to `glowforge_laser.c` and `serial.c`.
|
||||
following job ran unarmed. Owed: the driver fix on an image (the arm
|
||||
decided by the window alone, an RX overrun dropping the overrunning
|
||||
line whole and aborting the job), one bench drill of each scenario,
|
||||
and the catalog's `covers` widened to `glowforge_laser.c` and
|
||||
`serial.c`.
|
||||
21. **A sender change while a job runs: discussion.** Today a sender that
|
||||
disconnects mid-job leaves the motion running to the end of what the
|
||||
controller holds, with the window closed and fire suppressed (the
|
||||
consent belonged to the displaced session), so the job finishes dark
|
||||
and the material is left with an unfinished cut. This is the stock
|
||||
Grbl and grblHAL expectation for the motion: the controller has no
|
||||
notion of sender presence, executes what its planner and RX ring hold,
|
||||
and then waits; the core's stream code (`stream.c`,
|
||||
`stream_disconnect`) only switches streams, with no hold and no
|
||||
alarm, and senders treat a lost connection as a failed job (LightBurn
|
||||
stops its own side and resumes nothing). ForgeFIRM adds only the
|
||||
disarm on top. The open question is whether the disarm should also
|
||||
feed-hold the job, so a reconnecting sender can press and resume where
|
||||
the cut stopped instead of finding the head at the end of a dark pass:
|
||||
a hold parks the head over hot material with the assist air on the run
|
||||
profile, and the grace then closes the window in Hold as it does today;
|
||||
running on leaves a clean stop position but wastes the piece. Decide
|
||||
with the gapless pause and resume item (17), which owns the resume
|
||||
mechanics.
|
||||
22. **The flow check while the tube is lit.** The arm-time heater check
|
||||
starts at the session open, so with a prompt press the tube is lit
|
||||
for most of its window, and a lit CW window adds about 1.5 C to the
|
||||
rise (0.5 C at 45 % density) against a 1.6 C margin; on top of that the
|
||||
engine takes its baseline from one sample while the coolant ADC
|
||||
carries a common-mode offset of about 1 C that steps in when the
|
||||
airflow goes to the run profile, steps out when it returns to idle,
|
||||
and toggles between two levels in between. Together they put an
|
||||
ordinary job's check within a few tenths of the limit. Owed, in order:
|
||||
the engine's reading (means for the baseline and the end, the tube's
|
||||
share taken off from the `hv_current` integral, one coefficient per
|
||||
power model) on an image; three `flowload t1` runs to show the
|
||||
engine's rise back in the dark band; a `cooling.*` catalog case with
|
||||
an armed CW load; and if that is not enough, the void-on-emission
|
||||
design with the tube as its own flow tracer.
|
||||
Open question, the offset's source: the timing points at the airflow
|
||||
drive (the step lands one sample after the fans go to run duty, before
|
||||
any HV, and lifts when they go idle, long after the tube is dark), but
|
||||
high-voltage energy coupling into the lines between the sensors and
|
||||
the ADC is the other candidate and a shared path could show both; a
|
||||
scope on the two sensor lines through a session, fans and tube
|
||||
switched separately, decides.
|
||||
23. **Laser power-good: what the line means.** `cnc/laser_pgood` and its
|
||||
sampled count are defined in the UAPI (active low, one sample every
|
||||
~3.9 ms), the facts bank records that the sampled count reads 0 through
|
||||
real cutting, and the cooling engine warns
|
||||
`laser power-good degraded during the armed window` whenever fewer
|
||||
than half the samples read low, so the warning fires at every session
|
||||
open and carries no information. Nobody knows what the line reports
|
||||
on this PSU: whether it is the supply's own power-good, an HV-present
|
||||
flag, a polarity we have inverted, or unconnected. Owed: the line on a
|
||||
scope against `hv_current` through an armed cut, its meaning written
|
||||
into the facts bank and the UAPI, and then either a warning that means
|
||||
something or no warning.
|
||||
|
||||
**Deliberately not gated:** an armed GRBL job after an underrun cuts at the
|
||||
stale origin unless homing is required (GRBL mode permits unhomed cutting; the
|
||||
|
||||
Reference in New Issue
Block a user