Retire next-work item 1: the low-temperature gates are on the bench
The coolant floor and the warm-up gate are implemented, host-tested and bench-proven (CAMPAIGN-LOG has both runs, the heater-slug lesson included). BRINGUP: item 1 closed, items 2 to 20 are now 1 to 19, the six cross-references follow, and the facts bank carries the slug fact.
This commit is contained in:
@@ -4775,6 +4775,42 @@ before the fix was in). The attended set is deferred by decision. The
|
||||
campaign that authorizes a release runs on the image that carries every
|
||||
fix, burned once.
|
||||
|
||||
## 2026-08-31: the coolant floor and the warm-up gate, on the bench
|
||||
|
||||
The low-temperature gates landed (forgectrl 5a12f55 and 9d0b757, pinned
|
||||
in forgefirm f773866) and are bench-proven on the hot-deployed board,
|
||||
image 20260831141210. `cool_temp_min` is the `coolant_min` gate: under
|
||||
it the verdict is COLD with a hold, clearing 1 C above the floor
|
||||
(`gate_floor_trip`, host-tested); a header floor (CMrn) can only raise
|
||||
it. `cool_temp_start` is the `warm_up` gate: a run session opening under
|
||||
it holds (WARMUP, fire blocked, phase `warm-up`) with the loop heater at
|
||||
the flow duty and the fans idle, and releases into a normal run session
|
||||
with the run fans up and the flow check requested on a fresh history.
|
||||
The settings cross-check keeps floor under start under ceiling between
|
||||
gates that are on; both fields are on the panel's Cooling card.
|
||||
|
||||
The first bench run (16:15Z) passed its checks but released 11 s after
|
||||
the hold: with the pump on, the heater's slug reaches the upstream
|
||||
sensor within seconds and inflated the instant reading past the gate,
|
||||
while the bulk warms about half a degree a minute. The release now
|
||||
judges a one-minute rolling minimum of the upstream reading (between
|
||||
slugs it falls back to the bulk), the stall warning tracks the same
|
||||
number, and the catalog test refuses a release under 60 s. The second
|
||||
run (16:33Z) passed with the right physics: WARMUP held with the heater
|
||||
at 40 percent (26214 of 65535) and the fans idle, released at 75 s on
|
||||
the bulk minimum, heater off and run fans up after the release, COLD
|
||||
tripped with the start gate off, both gates at zero reported off with
|
||||
the run-start log line, and the settings restored.
|
||||
|
||||
`cooling.floor-and-warm-up` is the catalog case, proving both gates at
|
||||
room temperature by moving them above the loop; `cool_gate_test` holds
|
||||
the table rows and the floor hysteresis on the host. The warm-up
|
||||
holds indefinitely under its gate by design: a loop that stops warming
|
||||
(the heater plateaus 8 to 9 C over ambient) is named once and keeps
|
||||
holding, so a shop colder than about 8 C under the gate needs the gate
|
||||
lowered or the room warmed. The TEC item owns the chill side, with
|
||||
`cool_temp_min` as its floor.
|
||||
|
||||
## Superseded status notes
|
||||
|
||||
### Shared machine services — remaining polish, as listed 2026-08-13
|
||||
@@ -6309,6 +6345,22 @@ sentence is in the facts bank. Items 2 to 21 are now 1 to 20.
|
||||
margin widening warm; above that only a running tube warms the loop,
|
||||
and the check takes the tube's share off.
|
||||
|
||||
### Low-temperature gates and warm-up (item 1), closed 2026-08-31
|
||||
|
||||
Closed: implemented and bench-proven the same day (the entry above);
|
||||
the catalog case is `cooling.floor-and-warm-up`. Items 2 to 20 are now
|
||||
1 to 19.
|
||||
|
||||
1. **Low-temperature gates and warm-up (planned).** Two keys in the Cooling
|
||||
card: `cool_temp_min` (hard floor, default ~5 °C, a fire gate) and
|
||||
`cool_temp_start` (warm-up gate, default ~16 °C) — a job starting below the
|
||||
gate holds in a factory-style warm-up phase with the loop heater on and
|
||||
releases above it; below the floor nothing fires. Rationale: cold-tube
|
||||
thermal shock, condensation when the TEC pulls below the dew point, frozen
|
||||
coolant. Sequencing: warm-up first, flow check after. Measured physics on
|
||||
this bench: 50 % duty warms the bulk ~0.5–0.8 °C/min and plateaus ~8–9 °C
|
||||
above ambient — the same unaided limit the factory has.
|
||||
|
||||