mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-27 16:51:12 -07:00
BRINGUP: the Next work list runs 1 to 11, and the closing paragraph closes it
This commit is contained in:
+16
-15
@@ -1351,21 +1351,6 @@ feature requests, enhancements) will eventually be tracked as GitHub issues.
|
||||
shipped default of 2 is a starting point, not a truth), and the same
|
||||
shape fits any by-eye tunable the commissioning flow meets.
|
||||
|
||||
**Deliberately not gated:** an armed GRBL job after an underrun cuts at the
|
||||
stale origin unless homing is required (GRBL mode permits unhomed cutting; the
|
||||
underrun itself alarms and unlinks the anchor). Not in the acceptance catalog
|
||||
by design, for the same reason. From the pulse-header envelope, each by
|
||||
decision and each declared in the cloud client so every job's log counts it
|
||||
as decided rather than missed: the warm-up fan profile (the run profile
|
||||
covers the warm-up hold), the supply temperature window (the service sends
|
||||
the whole ADC range and the factory binds it to nothing; the supply is
|
||||
watched per job instead), the head, lid, interconnect and fused temperature
|
||||
ceilings (no sensor at those locations; the chassis is watched per job), the
|
||||
head accelerometer thresholds (the crash watch, on local knobs), the lid IR thresholds (the fire
|
||||
watch runs on local knobs; the header values stay ignored), the
|
||||
HV current caps (the sampled emission witness covers the idle case, and HV
|
||||
current is ranged per job), the thermal report upload conditions and the
|
||||
pump flag. Beam detect stays with item 6.
|
||||
9. **Audit remediation follow-through.** The 2026-09-01 audit's fixes are
|
||||
committed locally in every repository and host-tested, none pushed. Owed,
|
||||
in order: one pooled bench session on a locally built dev image (kernel
|
||||
@@ -1438,3 +1423,19 @@ pump flag. Beam detect stays with item 6.
|
||||
mode values, `/cool/status`, the gate table, the settings keys, the diag
|
||||
routes; regenerate its tables from `gates.c` and the settings table), dev
|
||||
tooling with no image consequence.
|
||||
|
||||
**Deliberately not gated:** an armed GRBL job after an underrun cuts at the
|
||||
stale origin unless homing is required (GRBL mode permits unhomed cutting; the
|
||||
underrun itself alarms and unlinks the anchor). Not in the acceptance catalog
|
||||
by design, for the same reason. From the pulse-header envelope, each by
|
||||
decision and each declared in the cloud client so every job's log counts it
|
||||
as decided rather than missed: the warm-up fan profile (the run profile
|
||||
covers the warm-up hold), the supply temperature window (the service sends
|
||||
the whole ADC range and the factory binds it to nothing; the supply is
|
||||
watched per job instead), the head, lid, interconnect and fused temperature
|
||||
ceilings (no sensor at those locations; the chassis is watched per job), the
|
||||
head accelerometer thresholds (the crash watch, on local knobs), the lid IR thresholds (the fire
|
||||
watch runs on local knobs; the header values stay ignored), the
|
||||
HV current caps (the sampled emission witness covers the idle case, and HV
|
||||
current is ranged per job), the thermal report upload conditions and the
|
||||
pump flag. Beam detect stays with item 6.
|
||||
|
||||
Reference in New Issue