Fan/thermal control done and bench-verified; docs updated
BRINGUP records the gate as complete with tach-verified results; LIGHTBURN.md documents the per-layer Air Assist toggle driving the cut-profile ventilation; fan_test.py joins the bench kit.
This commit is contained in:
+14
-12
@@ -220,18 +220,20 @@ hardware I/O — host testing).
|
||||
mapping) plus a chain-armed first-light procedure; the hardware
|
||||
verification prerequisites are complete. Interlock-trip recovery
|
||||
behavior remains to be exercised (non-scope check).
|
||||
- **Additional laser-on prerequisite (operator-mandated
|
||||
2026-08-02): fan/thermal control must be implemented first** —
|
||||
air assist + purge (head), exhaust + intake (thermal), and the
|
||||
coolant loop (water pump, TEC, water-temp monitoring). Factory
|
||||
run/idle/cooldown values are in the captured pulse headers
|
||||
(AAid/AArd/AAwd, EFid/EFrd/EFwd, IFid/IFrd/IFwd + CM/CT water
|
||||
thresholds — see `_RESOURCES/*.info` and the gfutilities
|
||||
settings map); kernel interfaces exist under
|
||||
/sys/glowforge/head and /sys/glowforge/thermal. Map into the
|
||||
driver as job-state-driven config (run at cycle start, cooldown
|
||||
after, idle thereafter) like the factory's
|
||||
`_config_from_pulse` scheme.
|
||||
- **Fan/thermal control (operator-mandated laser-on prerequisite):
|
||||
DONE 2026-08-02, bench-verified** (`glowforge_cooling.c` in the
|
||||
driver; test `scripts/bench/fan_test.py`). Factory pulse-header
|
||||
values throughout: init = pump on / TEC off / purge on / idle
|
||||
fans (air assist 204); **M8** (coolant flood — LightBurn's
|
||||
per-layer Air Assist) = cut profile (air 1023, exhaust 65535,
|
||||
intake 43278); **M9** = 15 s cooldown (`GFCOOL_COOLDOWN_S`) then
|
||||
idle. Water temp polled at 1 Hz vs the ~31 °C factory run
|
||||
ceiling → one-shot controller warning (laser milestone upgrades
|
||||
it to a hard fire gate). Verified via tach readbacks: air tach
|
||||
period 4439→699 under M8, exhaust stopped→full, intakes ~3×,
|
||||
cooldown hold, clean return to idle; coolant temp visibly
|
||||
dropped during the blast. TEC/heater control remain for the
|
||||
thermal part of the laser milestone.
|
||||
- **Interlock readback semantics cross-check: OPEN** (see
|
||||
factory-laser-safety-readbacks notes).
|
||||
3. **Homing (design decided 2026-08-02)**: the factory machine has NO
|
||||
|
||||