laser power-good: the line characterized, the kernel-drill guard, the probe, the dev image's mmap and ctypes
The supply's power-good line is active high, static across HV enable and emission, and driven; the facts bank and CAMPAIGN-LOG carry the measurement and the item closes. The kernel-drill latch-unlock guard read the old inverted value as HV not good, a check that was vacuous and would refuse every run once the module reads the line correctly; it now uses the chain's own witnesses, the charge-pump watchdog and the engine state. pgood_probe.py watches the line beside the chain through the kernel readbacks and is registered on the bench page. The dev image lists python3-mmap and python3-ctypes again for the pad-level bench tools the python trim had left without them.
This commit is contained in:
+21
-17
@@ -324,8 +324,10 @@ from the kernel counters. Contract: [forgectrl](https://docs.forgefirm.org/techn
|
||||
**Emission evidence.** `cnc/laser_on_sampled` (surfaced as `/status`
|
||||
`laser.emission_samples`) is the reliable live-emission witness; emission
|
||||
sensed with no armed window relocks the latch and stops motion. `pic/hv_current`
|
||||
is the only live HV telemetry on this PSU. `cnc/laser_pgood_sampled` is **not**
|
||||
a usable witness here — it reads 0 through real cutting.
|
||||
is the only live HV telemetry on this PSU. `cnc/laser_pgood` is the supply's
|
||||
power-good, driven high the whole time the supply is healthy (it follows
|
||||
neither HV_ENABLE nor emission): a supply-fault witness, never an emission
|
||||
witness (facts bank "Emission and HV witnesses").
|
||||
|
||||
## Lid, interlock and button policy
|
||||
|
||||
@@ -1031,8 +1033,22 @@ is committed.
|
||||
count on a commanded fire window and returns to 0 at Idle — the reliable
|
||||
witness. `pic/hv_current` tracks the cut (0 idle → hundreds/1023 raw while
|
||||
firing) and is the only live HV telemetry on this PSU (`hv_voltage` is
|
||||
grounded). `cnc/laser_pgood_sampled` stays 0 through real cutting: not usable
|
||||
here.
|
||||
grounded). **`cnc/laser_pgood` (J1_14, GPIO4_21) is the supply's power-good,
|
||||
active high**, measured 2026-09-01 through the kernel readbacks at ~780 Hz:
|
||||
the pin is high at idle, through four HV_ENABLE cycles of a dry run, and
|
||||
through an armed S400 cut (714 laser pulses, `hv_current` to 1023), with
|
||||
zero transitions in 225 s, and it stays high against a 100 kΩ pull-down
|
||||
switched in at the pad (IOMUXC `0x020E03C4`, restored to `0x100b0`), so the
|
||||
supply drives it. The supply's supervisor is a Weltrend WT7525 (PC-supply
|
||||
supervisor; open-drain PGO reports every DC output within spec, drops on an
|
||||
over/under-voltage or over-current fault, 300 ms delay after good), and the
|
||||
reverse-engineering pinout sheets label J1_14 `HV_PFC_STOP` (TP_A2C). The
|
||||
factory app reports the line as the `HVpg`/`HVps` tags and read it the same
|
||||
way (0 at idle under the old inverted convention). The kernel now reads it
|
||||
active high: `laser_pgood` 1 and `laser_pgood_sampled` 255 on a healthy
|
||||
supply; a drop during an armed window is the cooling engine's supply
|
||||
power-good warning, and it means a supply fault. The line has never been
|
||||
seen low on this machine.
|
||||
- **The head MCU flag register and HEAD_IRQ.** The head MCU (a KL17 at
|
||||
i2c-3 @0x47, I²C-slave-only to the SoC) samples four head-local GPIO input
|
||||
levels once per main loop into the read-only flag register 0x05: b0
|
||||
@@ -1270,19 +1286,7 @@ feature requests, enhancements) will eventually be tracked as GitHub issues.
|
||||
far): re-measure the two heat coefficients and the machine's
|
||||
air-assist offset; and if a lit check still trips, the
|
||||
void-on-emission design with the tube as its own flow tracer.
|
||||
8. **Laser power-good: what the line means.** `cnc/laser_pgood` and its
|
||||
sampled count are defined in the UAPI (active low, one sample every
|
||||
~3.9 ms), the facts bank records that the sampled count reads 0 through
|
||||
real cutting, and the cooling engine warns
|
||||
`laser power-good degraded during the armed window` whenever fewer
|
||||
than half the samples read low, so the warning fires at every session
|
||||
open and carries no information. Nobody knows what the line reports
|
||||
on this PSU: whether it is the supply's own power-good, an HV-present
|
||||
flag, a polarity we have inverted, or unconnected. Owed: the line on a
|
||||
scope against `hv_current` through an armed cut, its meaning written
|
||||
into the facts bank and the UAPI, and then either a warning that means
|
||||
something or no warning.
|
||||
9. **Initial commissioning: measure and set the machine's own numbers
|
||||
8. **Initial commissioning: measure and set the machine's own numbers
|
||||
methodically.** Every tunable that was measured on the bench machine
|
||||
and shipped as a default varies from machine to machine: the flow
|
||||
check's bands and `cool_flow_rise`, the tube's heat coefficients
|
||||
|
||||
Reference in New Issue