Add cooling.flow-under-load: the flow check with the tube lit through its window

A live catalog case: two 30 x 4 mm fills at full power on the press, the
window held open until the engine's flow verdict lands in the forgectrl
log, then M2 and the head brought back. PASS needs a verified line with
the laser's share on it (at least 0.3 C: the window and the fire
overlapped) and the judged rise at least 1 C under cool_flow_rise; an arm
refused by a gate names the gate. Passed on image 20260829190323
(heater rise 11.9 C judged, laser 0.6 off 12.5).

CAMPAIGN-LOG records the run and the day's two air-assist gate holds (a
bench connection, reseated); BRINGUP item 21 names the case.

Catalog: the case covers forgectrl src/cool.* and its neighbors; a new
test, so the manifest's coverage widens rather than moves.
This commit is contained in:
ScottW514
2026-08-29 16:39:03 -04:00
parent 5c282ce167
commit 61b68c387c
3 changed files with 171 additions and 5 deletions
+32
View File
@@ -4388,6 +4388,38 @@ and the reset came twice, 0.1 s apart: the tail of the blast arrived after
the first reset had flushed the ring and overran it again. Harmless, the
job was already stopped.
## 2026-08-29: the air-assist fan and the airflow gate, twice
Twice in the day the airflow gate held a job at the end of its 15 s grace
with the air-assist tach still at its idle reading (1895 at 17:09 in a
`flowload t2 40` run, 2207 at 20:19 in the first bench run of
`cooling.flow-under-load`; the floor is 6000 and every other session of the
day read about 10,700 within 5 s of the run profile). The head probed clean
and the kernel log carried no I2C error; the fan read normal at idle both
times. The gate did what it is for: the hold came before the arm, the
operator's press was refused, the session closed with the fans, and no job
ran without air. The operator's reading is a bench hardware glitch, the
head's pogo-pin connection to the air assist; the machine was powered down
and the head reseated, and the case was run again. Not a project item.
## 2026-08-29: `cooling.flow-under-load`, the catalog's case for the lit check
The catalog case for BRINGUP item 21 (`forgetest/suite/cooling.py`, kind
live, mode grbl, one press): two 30 x 4 mm fills at full power on the press,
the window held open until the engine's verdict lands in the forgectrl log,
then M2. PASS needs `coolant flow verified` with the laser's share on the
line (at least 0.3 C, the proof the window and the fire overlapped) and the
judged rise at least 1 C under `cool_flow_rise`; an arm refused by a gate
names the gate. First run on image 20260829190323 (the module staged over
the installed suite, forgetest restarted; the prerequisites overridden, no
campaign results on this image yet): the airflow gate held before the arm
(the entry above). Second run after the head reseat: **PASS**, the engine
line `coolant flow verified (heater rise 11.9 C, dT 9.5 C; laser 0.6 off
12.5)`, 66 s from job to verdict, the window closed 0.0 s after M2, the
head jogged back by the baseline; the case now brings the head back
itself. The case rides the next image; its campaign standing comes with
that image's campaign.