Add cooling.flow-under-load: the flow check with the tube lit through its window
A live catalog case: two 30 x 4 mm fills at full power on the press, the window held open until the engine's flow verdict lands in the forgectrl log, then M2 and the head brought back. PASS needs a verified line with the laser's share on it (at least 0.3 C: the window and the fire overlapped) and the judged rise at least 1 C under cool_flow_rise; an arm refused by a gate names the gate. Passed on image 20260829190323 (heater rise 11.9 C judged, laser 0.6 off 12.5). CAMPAIGN-LOG records the run and the day's two air-assist gate holds (a bench connection, reseated); BRINGUP item 21 names the case. Catalog: the case covers forgectrl src/cool.* and its neighbors; a new test, so the manifest's coverage widens rather than moves.
This commit is contained in:
@@ -4388,6 +4388,38 @@ and the reset came twice, 0.1 s apart: the tail of the blast arrived after
|
||||
the first reset had flushed the ring and overran it again. Harmless, the
|
||||
job was already stopped.
|
||||
|
||||
## 2026-08-29: the air-assist fan and the airflow gate, twice
|
||||
|
||||
Twice in the day the airflow gate held a job at the end of its 15 s grace
|
||||
with the air-assist tach still at its idle reading (1895 at 17:09 in a
|
||||
`flowload t2 40` run, 2207 at 20:19 in the first bench run of
|
||||
`cooling.flow-under-load`; the floor is 6000 and every other session of the
|
||||
day read about 10,700 within 5 s of the run profile). The head probed clean
|
||||
and the kernel log carried no I2C error; the fan read normal at idle both
|
||||
times. The gate did what it is for: the hold came before the arm, the
|
||||
operator's press was refused, the session closed with the fans, and no job
|
||||
ran without air. The operator's reading is a bench hardware glitch, the
|
||||
head's pogo-pin connection to the air assist; the machine was powered down
|
||||
and the head reseated, and the case was run again. Not a project item.
|
||||
|
||||
## 2026-08-29: `cooling.flow-under-load`, the catalog's case for the lit check
|
||||
|
||||
The catalog case for BRINGUP item 21 (`forgetest/suite/cooling.py`, kind
|
||||
live, mode grbl, one press): two 30 x 4 mm fills at full power on the press,
|
||||
the window held open until the engine's verdict lands in the forgectrl log,
|
||||
then M2. PASS needs `coolant flow verified` with the laser's share on the
|
||||
line (at least 0.3 C, the proof the window and the fire overlapped) and the
|
||||
judged rise at least 1 C under `cool_flow_rise`; an arm refused by a gate
|
||||
names the gate. First run on image 20260829190323 (the module staged over
|
||||
the installed suite, forgetest restarted; the prerequisites overridden, no
|
||||
campaign results on this image yet): the airflow gate held before the arm
|
||||
(the entry above). Second run after the head reseat: **PASS**, the engine
|
||||
line `coolant flow verified (heater rise 11.9 C, dT 9.5 C; laser 0.6 off
|
||||
12.5)`, 66 s from job to verdict, the window closed 0.0 s after M2, the
|
||||
head jogged back by the baseline; the case now brings the head back
|
||||
itself. The case rides the next image; its campaign standing comes with
|
||||
that image's campaign.
|
||||
|
||||