forgetest tests: the confirmed trims of the tool's own unit tests

The cases that tested a mock, a timer, a wording or a table, or that
replayed a judgment a host test already holds, leave forgetest/tests.
What catches a false PASS, keeps the bench safe, or guards the gate
stays.

- test_baseline: the fake sysfs tree is a mixin with no test_ methods,
  so ExtensionFreeTests and BaselineModeTests no longer re-run
  BaselineTests' 25 cases (133 runs, now 45). CoolPublishTests, the
  lamp-fade cases and TransientNotLeftoverTests go; PositionDeadbandTests
  keeps a reading past the band and an unreadable reading, both never
  excused. Both latch-relock cases stay.
- test_fixture: MdnsTests, the three timing cases, the probe's log
  wording, and nine prompt-routing variants go. A live test never runs
  unattended, the arm-press opt-in, the short-press edge, the presence
  press handing over the arm press, and the arm notice dropping at the
  press stay (35 cases, now 21).
- test_cloud_suite: three false-PASS guards stay: the latch open at a
  dark print's button, a lid stop that is not edge-driven, the kernel
  refusing the resume. The guards for the latch unlocking in the hold
  and a paused print resuming left with their catalog tests in 6a434bb.
  The rest go, with the harness pieces and the hunt-lid fixture only
  they read (41 cases, now 3).
- test_cooling_suite: GateOffTests, CriticalTierTests, FanGateTests and
  FansQuietTests go with their harness; the flow verdict's log reads
  stay: only the text after the offset, never an older verdict before it
  (the flow-under-load false-PASS guard), a rotated log read whole.
- test_queue: RunClockTests and three ordering cases go, and refusals
  are judged by a reason given, not its words; both live
  acknowledgment cases stay.
- test_takeover_position: the six cases that judge the head and move
  nothing stay.
- test_camera_home_return: the five cases where the head must not move
  stay, and so do the three that check the hand-back jog's direction and
  distance (homed, unhomed with the counters not counted twice, after
  cloud mode): a wrong sign or a double count drives the head into the
  gantry stops (15 cases, now 8).
- test_server: the keep-alive and ETag cases, the takeover and scope
  half of the bench case, and the page's self-contained asserts
  (test_page.py's) go.
- test_operator: the wording cases, the fixture case (test_fixture.py's)
  and JournalTests go.
- test_mode: the supervisor timeout table goes.
- test_takeover_client: the listener, the offline service back, the
  online client without the hunt, and GRBL under no marker stay.
- test_responsiveness: PageTests and ImplementationCostTests go; the
  log cache keeps appends, a partial line, a replaced file and a fresh
  list, and the fingerprint cache a changed manifest and one with no
  content hash.
- test_bench_registry: GfbenchTests and two description and argument
  pins go.
- test_installer: the log-format and TLS-wording cases and
  InstallerShapeTests go; the die case checks the reason is in the log,
  not its format.
- test_image: KernelIdentTests and the registration pin go.

Each file's __main__ guard now ends the file, and the docstrings say what
each still proves.

Proof: each of the fifteen files passes under Linux as forgetest-ci
discovers it, and pyflakes reports nothing new in them.

Acceptance: none; test-only.
This commit is contained in:
ScottW514
2026-10-13 20:29:25 -04:00
parent 8536ae7076
commit 520d62ac05
16 changed files with 78 additions and 2848 deletions
+8 -765
View File
@@ -3,774 +3,16 @@
# https://community.openglow.org
# SPDX-License-Identifier: MIT
"""cooling.fans-quiet-after-motion and cooling.gate-off replayed host-side
under the real runner Context against a scripted machine: a fake
forgectrl (/status fans, /cool/status phase and verdict, /settings with
the gates table, /logs/tail), a fake kernel sysfs (the fan duties), and
a fake Grbl port that answers '?' and every command.
The bench case that motivated this: the test started one second after
the engine of a previous test went idle, took the tachs still coasting
at the cooldown level as its idle reference, and then waited for the
fans to come back UP to it. The idle reference now needs the engine
idle, the idle duty applied, and tachs that have stopped changing; the
pass condition is at-or-below that level, and every sample is logged.
"""
"""cooling.flow-under-load reads the engine's flow verdict from what the
forgectrl log gained since the job began: only the text after the offset,
never an older verdict before it, and the whole of a log rotated under
the test."""
import os
import shutil
import socket
import tempfile
import threading
import time
import unittest
import helpers
from forgetest.runner import Context, Failed, Run
from forgetest.suite import cooling, motion
class EngineLog:
"""The engine's log lines, as the tests read them: appended to a scratch
forgectrl log (a check reads the lines written after its mark) and to the
fake /logs/tail."""
def log_setup(self):
self.logdir = tempfile.mkdtemp(prefix="forgetest-cool-")
self.saved_log = motion.FORGECTRL_LOG
motion.FORGECTRL_LOG = os.path.join(self.logdir, "forgectrl.log")
open(motion.FORGECTRL_LOG, "w").close()
def log_teardown(self):
motion.FORGECTRL_LOG = self.saved_log
shutil.rmtree(self.logdir, ignore_errors=True)
def emit(self, text):
self.fc.state.setdefault("logs_tail", {"text": ""})["text"] += text
with open(motion.FORGECTRL_LOG, "a", encoding="utf-8") as f:
f.write(text)
class FakeGrbl:
"""Answers '?' with an Idle report and every line with ok."""
def __init__(self):
self.sock = socket.socket()
self.sock.bind(("127.0.0.1", 0))
self.sock.listen(2)
os.environ["GRBL_HOST"] = "127.0.0.1"
os.environ["GRBL_PORT"] = str(self.sock.getsockname()[1])
self.commands = []
self.on_command = None
self._stop = False
threading.Thread(target=self._serve, daemon=True).start()
def _serve(self):
self.sock.settimeout(0.2)
while not self._stop:
try:
c, _ = self.sock.accept()
except OSError:
continue
threading.Thread(target=self._client, args=(c,), daemon=True).start()
def _client(self, c):
c.settimeout(0.1)
buf = b""
c.sendall(b"\r\nGrbl 1.1f ['$' for help]\r\n")
while not self._stop:
try:
d = c.recv(4096)
except socket.timeout:
continue
except OSError:
break
if not d:
break
for ch in d:
if ch == 0x3F: # '?'
c.sendall(b"<Idle|MPos:0.000,0.000,0.000|FS:0,0>\r\n")
elif ch in (0x18, 0x85):
pass
else:
buf += bytes([ch])
while b"\n" in buf:
line, buf = buf.split(b"\n", 1)
line = line.decode().strip()
if line:
self.commands.append(line)
if self.on_command:
self.on_command(line)
c.sendall(b"ok\r\n")
c.close()
def close(self):
self._stop = True
self.sock.close()
for k in ("GRBL_HOST", "GRBL_PORT"):
os.environ.pop(k, None)
class FansQuietTests(unittest.TestCase):
def setUp(self):
self.tmp = tempfile.mkdtemp(prefix="forgetest-cool-")
self.sysfs = os.path.join(self.tmp, "sysfs") + os.sep
os.makedirs(self.sysfs + "thermal")
os.makedirs(self.sysfs + "cnc")
with open(self.sysfs + "cnc/state", "w") as f:
f.write("idle")
os.environ["GF_SYSFS_ROOT"] = self.sysfs
self.fc = helpers.FakeForgectrl().start()
self.grbl = FakeGrbl()
self.saved = (cooling.SAMPLE_S, cooling.IDLE_REF_TIMEOUT_S, cooling.COOLDOWN_TIMEOUT_S,
cooling.RESTART_IDLE_TIMEOUT_S, cooling.hw.initd)
cooling.SAMPLE_S = 0.1
cooling.IDLE_REF_TIMEOUT_S = 3
cooling.COOLDOWN_TIMEOUT_S = 4
cooling.RESTART_IDLE_TIMEOUT_S = 1
# The daemon restart of the last phase, scripted: the init script
# is a stub, and the engine that comes up applies `after_start`
# (the idle duties by default; a daemon that keeps the busy-start
# cooldown airflow applies those instead).
self.initd_calls = []
self.after_start = (0, 0)
def initd(service, action, timeout=60):
self.initd_calls.append((service, action))
if action == "start":
self.duty(*self.after_start)
return 0, ""
cooling.hw.initd = initd
self.fc.state["cool"] = {"phase": "idle", "armed": False, "hold": False}
self.duty(0, 0)
self.fans(0, 736, 733)
def tearDown(self):
(cooling.SAMPLE_S, cooling.IDLE_REF_TIMEOUT_S, cooling.COOLDOWN_TIMEOUT_S,
cooling.RESTART_IDLE_TIMEOUT_S, cooling.hw.initd) = self.saved
self.grbl.close()
self.fc.stop()
os.environ.pop("GF_SYSFS_ROOT", None)
shutil.rmtree(self.tmp, ignore_errors=True)
# -- the machine -------------------------------------------------------
def duty(self, exhaust, intake):
for attr, v in (("thermal/exhaust_pwm", exhaust), ("thermal/intake_pwm", intake)):
with open(self.sysfs + attr, "w") as f:
f.write(str(v))
def fans(self, exhaust, i1, i2, air=2080):
self.fc.state["status"] = dict(self.fc.state["status"],
fans={"air_assist": air, "exhaust": exhaust, "intake_1": i1, "intake_2": i2})
def run_engine(self):
"""M8 -> run profile; M9 -> smoke phase, then idle duty, then the
tachs coast down (a few samples of spin-down), like forgectrl's
engine on the bench."""
def on_command(line):
if line == "M8":
self.duty(65535, 43278)
self.fc.state["cool"]["phase"] = "run"
self.fans(6753, 3212, 3328, air=10997)
elif line == "M9":
def cooldown():
self.fc.state["cool"]["phase"] = "smoke"
time.sleep(0.3)
self.fc.state["cool"]["phase"] = "idle"
self.duty(0, 0)
for ex, i1 in ((5030, 3319), (3100, 2200), (1200, 1300), (0, 740)):
self.fans(ex, i1, i1 + 5)
time.sleep(0.25)
threading.Thread(target=cooldown, daemon=True).start()
self.grbl.on_command = on_command
def run_test(self):
run = Run("test", "cooling.fans-quiet-after-motion", "t")
ctx = Context(run, None, helpers.make_test("cooling.fans-quiet-after-motion", []))
cooling.fans_quiet(ctx)
return run
# -- cases ------------------------------------------------------------------
def test_idle_machine_passes_and_logs_every_sample(self):
self.run_engine()
run = self.run_test()
self.assertEqual(run.evidence["before"]["exhaust"], 0)
self.assertIsNotNone(run.evidence["settle_s"])
self.assertEqual(run.evidence["duty_after"], cooling.IDLE_DUTY)
self.assertIn("M8", self.grbl.commands)
self.assertIn("M9", self.grbl.commands)
cooldown_lines = [ln for ln in run.lines if "cooldown +" in ln]
self.assertGreaterEqual(len(cooldown_lines), 2, run.lines)
def test_a_spin_down_in_progress_is_not_taken_as_the_idle_reference(self):
"""The bench case: the previous test's fans are still coasting when
this one starts. The reference waits for them to settle, and the
run passes instead of waiting for the fans to come back up."""
self.run_engine()
self.fans(5030, 3319, 3377) # coasting, engine already idle, duty 0
def coast():
for ex, i1 in ((3900, 2600), (2500, 1700), (1100, 1000), (0, 736), (0, 736)):
time.sleep(0.12)
self.fans(ex, i1, i1 + 5)
threading.Thread(target=coast, daemon=True).start()
run = self.run_test()
self.assertEqual(run.evidence["before"]["exhaust"], 0, run.evidence["before"])
self.assertGreater(run.evidence["idle_ref_s"], 0.3)
self.assertIsNotNone(run.evidence["settle_s"])
self.assertTrue(any("idle ref:" in ln for ln in run.lines))
def test_the_restart_phase_stops_disables_starts_and_sees_idle_duty(self):
self.run_engine()
run = self.run_test()
self.assertEqual(run.finished, None)
self.assertEqual(self.initd_calls, [("forgectrl", "stop"), ("forgectrl", "start")])
with open(self.sysfs + "cnc/disable") as f:
self.assertEqual(f.read(), "1")
self.assertEqual(run.evidence["duty_after_restart"], cooling.IDLE_DUTY)
self.assertIsNotNone(run.evidence["restart_idle_s"])
def test_a_daemon_that_keeps_the_busy_start_airflow_fails(self):
# The bench case: after a takeover's restart the exhaust ran at
# cooldown duty on an idle machine for good.
self.run_engine()
self.after_start = (32768, 21639)
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("kept the busy-start airflow", str(cm.exception))
self.assertIn("32768", str(cm.exception))
def test_fans_left_running_fail_with_the_reference_in_the_message(self):
def on_command(line):
if line == "M8":
self.duty(65535, 43278)
self.fc.state["cool"]["phase"] = "run"
self.fans(6753, 3212, 3328)
# M9 ignored: the run profile stays on
self.grbl.on_command = on_command
run = Run("test", "cooling.fans-quiet-after-motion", "t")
ctx = Context(run, None, helpers.make_test("cooling.fans-quiet-after-motion", []))
with self.assertRaises(Failed) as cm:
cooling.fans_quiet(ctx)
self.assertIn("did not return to the idle profile", str(cm.exception))
self.assertIn("idle reference", str(cm.exception))
self.assertIn("65535", str(cm.exception))
def test_a_reference_that_never_settles_fails_early_and_says_so(self):
def churn():
seq = (1000, 4000, 2500, 700, 3300, 1600, 4200) # aperiodic against the sampler
i = 0
while not self.grbl._stop:
v = seq[i % len(seq)]
i += 1
self.fans(v, v, v)
time.sleep(0.03)
threading.Thread(target=churn, daemon=True).start()
run = Run("test", "cooling.fans-quiet-after-motion", "t")
ctx = Context(run, None, helpers.make_test("cooling.fans-quiet-after-motion", []))
with self.assertRaises(Failed) as cm:
cooling.fans_quiet(ctx)
self.assertIn("never settled to an idle reference", str(cm.exception))
self.assertEqual(self.grbl.commands, []) # nothing was jogged
if __name__ == "__main__":
unittest.main()
class GateOffTests(EngineLog, unittest.TestCase):
"""cooling.gate-off against a scripted engine: the fake forgectrl
re-reads the ceiling at every M8 (as the engine reloads its tunables
at run start), trips OVERTEMP when the coolant is over it, skips the
gate and reports gates_off when the ceiling sits at its top, and
writes the run-start line the test looks for."""
TOP, BOTTOM = 60.0, 5.0
def setUp(self):
self.fc = helpers.FakeForgectrl().start()
self.log_setup()
self.grbl = FakeGrbl()
self.saved = (cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S)
cooling.VERDICT_WAIT_S = 3
cooling.SESSION_END_WAIT_S = 3
self.fc.state["status"] = dict(self.fc.state["status"],
coolant={"down_c": 22.4, "up_c": 22.3, "pump": True, "tec": False},
temps={"chassis_c": 29.0, "supply_raw": 589, "soc_c": 42.8,
"soc_throttle": 0},
gates_off=[])
self.fc.state["cool"] = {"phase": "idle", "verdict": "OK", "fire_ok": False, "hold": False,
"gates_off": []}
self.fc.state["settings"].update({"cool_temp_max": "", "cool_temp_resume": ""})
self.log_line = True # the engine writes its run-start line
self.temps_line = True # the engine writes its run-end temperature line
self.report_off = True # the engine reports the off gate
self.trips = True # the engine trips a low ceiling
self.sessions = 0 # run sessions the engine saw (M8 with the phase not run)
self._describe()
self.grbl.on_command = self._engine
self.fc.on_post = self._on_post
def tearDown(self):
cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S = self.saved
self.grbl.close()
self.fc.stop()
self.log_teardown()
# -- the scripted machine --------------------------------------------------
def ceiling(self):
v = self.fc.state["settings"].get("cool_temp_max") or ""
return float(v) if v else 33.0
def _describe(self):
"""/settings carries the gates table the way forgectrl's gates.c
publishes it, classified from the stored value."""
v = self.ceiling()
state = "off" if v >= self.TOP else ("ok" if 25 <= v <= 38 else "warn")
self.fc.state["settings"]["gates"] = {
"cool_temp_max": {"gate": "coolant_max", "def": 33, "lo": self.BOTTOM, "hi": self.TOP,
"band": [25, 38], "off": "high", "value": v, "state": state}}
def _on_post(self, path, form):
"""The real settings reply re-classifies the gates from the new values."""
if path != "/settings":
return None
self.fc.state["settings"].update(form)
self._describe()
return (200, self.fc.state["settings"])
def _engine(self, line):
"""M8 opens a run session: the engine re-reads the ceiling and
ticks the gate. M9 ends it a report period later (the phase
leaves run); a hold taken against the old ceiling stands until
the next session re-reads."""
self._describe()
cool = self.fc.state["cool"]
if line == "M9":
def end():
time.sleep(0.3)
cool["phase"] = "smoke"
if self.temps_line:
self.emit(
"Aug 22 12:00:30 forgectrl: cool: temps this job: chassis 29.0..29.4 C, "
"soc 42.8..47.1 C, supply raw 587..592\n")
time.sleep(0.2)
cool["phase"] = "idle"
threading.Thread(target=end, daemon=True).start()
return
if line != "M8":
return
self.sessions += 1
cool["phase"] = "run"
v = self.ceiling()
off = v >= self.TOP
if off and self.log_line:
self.emit(
"Aug 21 12:00:00 forgectrl: cool: gate coolant_max OFF: cool_temp_max = 60 "
"(the high end of 5 to 60; recommended 25 to 38, default 33)\n")
gates_off = ["coolant_max"] if off and self.report_off else []
if not off and self.trips and 22.3 > v:
cool.update(verdict="OVERTEMP", fire_ok=False, hold=True, gates_off=gates_off)
else:
cool.update(verdict="OK", fire_ok=True, hold=False, gates_off=gates_off)
self.fc.state["status"]["gates_off"] = gates_off
def run_test(self):
run = Run("test", "cooling.gate-off", "t")
ctx = Context(run, None, helpers.make_test("cooling.gate-off", []))
cooling.gate_off(ctx)
return run
def settings_posts(self):
return [f for p, f in self.fc.posts if p == "/settings"]
# -- cases ------------------------------------------------------------------
def test_trip_then_off_then_restored_passes(self):
run = self.run_test()
self.assertEqual(run.evidence["trip"]["verdict"], "OVERTEMP")
self.assertEqual(run.evidence["off"]["gates_off"], ["coolant_max"])
self.assertEqual(run.evidence["restored"]["verdict"], "OK")
posts = self.settings_posts()
self.assertEqual(posts[0], {"cool_temp_max": "6.0", "cool_temp_resume": "5.0"})
self.assertEqual(posts[1], {"cool_temp_max": "60.0", "cool_temp_resume": ""})
self.assertEqual(posts[-1], {"cool_temp_max": "", "cool_temp_resume": ""})
self.assertEqual(self.fc.state["settings"]["cool_temp_max"], "")
self.assertEqual(self.grbl.commands.count("M8"), 3)
self.assertEqual(self.grbl.commands.count("M9"), 3)
def test_an_engine_that_does_not_trip_fails_and_restores(self):
self.trips = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("did not trip", str(cm.exception))
self.assertEqual(self.settings_posts()[-1], {"cool_temp_max": "", "cool_temp_resume": ""})
self.assertEqual(self.fc.state["settings"]["cool_temp_max"], "")
# The restore cycles a run session so the engine re-reads the
# restored values; the bench is not left holding on the test's.
self.assertEqual(self.grbl.commands.count("M8"), 2)
self.assertEqual(self.grbl.commands.count("M9"), 2)
self.assertEqual(self.fc.state["cool"]["verdict"], "OK")
def test_every_session_waits_for_the_previous_one_to_end(self):
"""Each M8 must find the engine out of phase run, or the engine
never re-reads: the bench failure behind this case sent M9 and
the next M8 300 ms apart and the 1 Hz report pipeline swallowed
the session end."""
seen = []
inner = self._engine
def engine(line):
if line == "M8":
seen.append(self.fc.state["cool"]["phase"])
inner(line)
self.grbl.on_command = engine
self.run_test()
self.assertEqual(seen, ["idle", "idle", "idle"])
self.assertEqual(self.sessions, 3)
def test_an_engine_that_hides_the_off_gate_fails(self):
self.report_off = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("gates_off", str(cm.exception))
self.assertEqual(self.fc.state["settings"]["cool_temp_max"], "")
def test_a_missing_run_start_log_line_fails(self):
self.log_line = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("run-start log line", str(cm.exception))
self.assertEqual(self.fc.state["settings"]["cool_temp_max"], "")
def test_an_earlier_runs_line_is_not_this_runs(self):
# The off gate's line from a run before this one is in the log, and
# the engine writes none this time: the line judged is one written
# after the test's own mark, so the old one does not pass for it.
self.emit("Aug 21 11:00:00 forgectrl: cool: gate coolant_max OFF: cool_temp_max = 60 "
"(the high end of 5 to 60; recommended 25 to 38, default 33)\n")
self.log_line = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("run-start log line", str(cm.exception))
self.assertEqual(self.fc.state["settings"]["cool_temp_max"], "")
def test_a_missing_run_end_temperature_line_fails(self):
self.temps_line = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("board-temperature line", str(cm.exception))
def test_a_custom_ceiling_is_restored_verbatim(self):
self.fc.state["settings"].update({"cool_temp_max": "30", "cool_temp_resume": "28"})
self._describe()
run = self.run_test()
self.assertEqual(run.evidence["orig"], {"cool_temp_max": "30", "cool_temp_resume": "28"})
self.assertEqual(self.settings_posts()[-1], {"cool_temp_max": "30", "cool_temp_resume": "28"})
self.assertEqual(self.fc.state["settings"]["cool_temp_max"], "30")
class CriticalTierTests(EngineLog, unittest.TestCase):
"""cooling.critical-tier against a scripted engine: two tiers on the
coolant, the fail tier winning over the pause tier in a run session
and ending with it, the critical line off at its top, and the settings
cross-check refusing a critical line at or below the ceiling."""
UP = 22.3
ROWS = { # key: (gate, default, lo, hi, band_lo, band_hi, off)
"cool_temp_max": ("coolant_max", 33.0, 5.0, 60.0, 25.0, 38.0, "high"),
"cool_temp_resume": (None, 31.0, 5.0, 59.0, 20.0, 36.0, "none"),
"cool_temp_critical_c": ("coolant_critical", 38.0, 6.0, 70.0, 36.0, 45.0, "high"),
}
def setUp(self):
self.fc = helpers.FakeForgectrl().start()
self.log_setup()
self.grbl = FakeGrbl()
self.saved = (cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S)
cooling.VERDICT_WAIT_S = 3
cooling.SESSION_END_WAIT_S = 3
self.fc.state["status"] = dict(self.fc.state["status"],
coolant={"down_c": 22.4, "up_c": self.UP, "pump": True, "tec": False},
gates_off=[])
self.fc.state["cool"] = {"phase": "idle", "verdict": "OK", "fire_ok": False, "hold": False,
"gates_off": []}
for k in self.ROWS:
self.fc.state["settings"].setdefault(k, "")
self.fc.state["logs_tail"] = {"text": ""}
self.faults = True # the engine has the critical tier
self.ends_with_session = True
self.cross_checks = True # the settings API refuses crit <= max
self._describe()
self.grbl.on_command = self._engine
self.fc.on_post = self._on_post
def tearDown(self):
cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S = self.saved
self.grbl.close()
self.fc.stop()
self.log_teardown()
def setting(self, key):
v = self.fc.state["settings"].get(key) or ""
return float(v) if v else self.ROWS[key][1]
def _describe(self):
gates = {}
for k, (gate, d, lo, hi, blo, bhi, off) in self.ROWS.items():
v = self.setting(k)
state = "off" if (off == "high" and v >= hi) else ("ok" if blo <= v <= bhi else "warn")
gates[k] = {"gate": gate, "def": d, "lo": lo, "hi": hi, "band": [blo, bhi], "off": off,
"value": v, "state": state}
self.fc.state["settings"]["gates"] = gates
def _on_post(self, path, form):
if path != "/settings":
return None
if self.cross_checks:
merged = dict(self.fc.state["settings"])
merged.update(form)
tmax = float(merged.get("cool_temp_max") or 33.0)
tcrit = float(merged.get("cool_temp_critical_c") or 38.0)
ceiling_off = tmax >= self.ROWS["cool_temp_max"][3]
if not ceiling_off and tcrit <= tmax:
return (400, {"error": "cool_temp_critical_c must be above cool_temp_max"})
self.fc.state["settings"].update(form)
self._describe()
return (200, self.fc.state["settings"])
def _verdict_idle(self):
"""Outside a run only the ceiling's pause tier stands."""
return "OVERTEMP" if self.UP > self.setting("cool_temp_max") else "OK"
def _engine(self, line):
self._describe()
cool = self.fc.state["cool"]
if line == "M9":
def end():
time.sleep(0.3)
cool["phase"] = "idle"
if self.ends_with_session or cool["verdict"] != "CRITICAL":
v = self._verdict_idle()
cool.update(verdict=v, fire_ok=v == "OK", hold=v != "OK", reason="")
threading.Thread(target=end, daemon=True).start()
return
if line != "M8":
return
cool["phase"] = "run"
tmax, tcrit = self.setting("cool_temp_max"), self.setting("cool_temp_critical_c")
crit_off = tcrit >= self.ROWS["cool_temp_critical_c"][3]
off = ["coolant_critical"] if crit_off else []
if crit_off:
self.emit(
"Aug 22 12:00:00 forgectrl: cool: gate coolant_critical OFF: cool_temp_critical_c = 70 "
"(the high end of 6 to 70; recommended 36 to 45, default 38)\n")
if self.faults and not crit_off and self.UP >= tcrit:
cool.update(verdict="CRITICAL", fire_ok=False, hold=True, resume_ok=False,
reason="CRITICAL: coolant %.1f C at or over the %.0f C critical line - hold, "
"no resume this job" % (self.UP, tcrit), gates_off=off)
elif self.UP > tmax:
cool.update(verdict="OVERTEMP", fire_ok=False, hold=True, resume_ok=False,
reason="coolant over the ceiling", gates_off=off)
else:
cool.update(verdict="OK", fire_ok=True, hold=False, resume_ok=True, reason="", gates_off=off)
self.fc.state["status"]["gates_off"] = off
def run_test(self):
run = Run("test", "cooling.critical-tier", "t")
ctx = Context(run, None, helpers.make_test("cooling.critical-tier", []))
cooling.critical_tier(ctx)
return run
def settings_posts(self):
return [f for p, f in self.fc.posts if p == "/settings"]
# -- cases ------------------------------------------------------------------
def test_fault_then_off_then_restored_passes(self):
run = self.run_test()
self.assertEqual(run.evidence["cross_check"]["status"], 400)
self.assertEqual(run.evidence["critical"]["verdict"], "CRITICAL")
self.assertEqual(run.evidence["critical_after"]["verdict"], "OVERTEMP")
self.assertEqual(run.evidence["critical_off"]["gates_off"], ["coolant_critical"])
self.assertEqual(run.evidence["restored"]["verdict"], "OK")
self.assertEqual(run.evidence["ceiling_off_accepted"], 200)
posts = self.settings_posts()
# refused cross-check, the ceiling at its off end (accepted), its undo, then the low leg
self.assertEqual(posts[1], {"cool_temp_max": "60.0"})
self.assertEqual(posts[3], {"cool_temp_max": "6.0", "cool_temp_resume": "5.0",
"cool_temp_critical_c": "7.0"})
self.assertEqual(posts[-1], {"cool_temp_max": "", "cool_temp_resume": "", "cool_temp_critical_c": ""})
self.assertEqual(self.grbl.commands.count("M8"), 3)
self.assertEqual(self.grbl.commands.count("M9"), 3)
def test_an_engine_without_the_tier_fails_and_restores(self):
self.faults = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("did not fault", str(cm.exception))
self.assertEqual(self.settings_posts()[-1],
{"cool_temp_max": "", "cool_temp_resume": "", "cool_temp_critical_c": ""})
self.assertEqual(self.fc.state["cool"]["verdict"], "OK")
def test_a_fault_that_outlives_its_session_fails(self):
self.ends_with_session = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("after the faulted session", str(cm.exception))
def test_a_missing_cross_check_fails_before_any_session(self):
self.cross_checks = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("was accepted", str(cm.exception))
self.assertEqual(self.grbl.commands.count("M8"), 0)
class FanGateTests(unittest.TestCase):
"""cooling.fan-gate-trips against a scripted engine: the fake reads the
floors at every M8 (the engine reloads at run start), holds every fan
in grace for the configured seconds, then judges the bench readings
(exhaust 6753, intakes 3212/3328, air assist 10997 rpm, purge 628)
against the floors: a floor a reading cannot meet trips AIRFLOW three
ticks after the grace, a floor of zero reads off."""
READINGS = {"exhaust": 6753, "intake_1": 3212, "intake_2": 3328, "air_assist": 10997, "purge": 628}
FLOORS = {"exhaust": ("cool_tach_exhaust_min_rpm", 3700.0, 20000.0),
"intake_1": ("cool_tach_intake_min_rpm", 1800.0, 20000.0),
"intake_2": ("cool_tach_intake_min_rpm", 1800.0, 20000.0),
"air_assist": ("cool_tach_air_assist_min_rpm", 6000.0, 30000.0),
"purge": ("cool_purge_min_current", 300.0, 1023.0)}
GATE_OF = {"exhaust": "exhaust", "intake_1": "intake", "intake_2": "intake",
"air_assist": "air_assist", "purge": "purge"}
def setUp(self):
self.fc = helpers.FakeForgectrl().start()
self.grbl = FakeGrbl()
self.saved = (cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S, cooling.FAN_TRIP_WAIT_S)
cooling.VERDICT_WAIT_S = 4
cooling.SESSION_END_WAIT_S = 3
cooling.FAN_TRIP_WAIT_S = 4
self.fc.state["status"] = dict(self.fc.state["status"], gates_off=[])
self.fc.state["cool"] = {"phase": "idle", "verdict": "OK", "fire_ok": False, "hold": False,
"gates_off": [], "fan_gates": {}}
for key, _d, _h in self.FLOORS.values():
self.fc.state["settings"].setdefault(key, "")
self.fc.state["settings"].setdefault("cool_fan_grace_s", "")
self.trips = True # the engine trips an unmeetable floor
self.reports_off = True # the engine reports a zero floor as off
self.grace_scale = 0.1 # seconds of fake grace per configured second
self._describe()
self.grbl.on_command = self._engine
self.fc.on_post = self._on_post
def tearDown(self):
cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S, cooling.FAN_TRIP_WAIT_S = self.saved
self.grbl.close()
self.fc.stop()
def setting(self, key, default):
v = self.fc.state["settings"].get(key) or ""
return float(v) if v else default
def _describe(self):
gates = {}
for fan, (key, default, hi) in self.FLOORS.items():
v = self.setting(key, default)
gates[key] = {"gate": self.GATE_OF[fan], "def": default, "lo": 0.0, "hi": hi,
"band": [default * 0.7, default * 1.4], "off": "low", "value": v,
"state": "off" if v <= 0 else "ok"}
g = self.setting("cool_fan_grace_s", 15.0)
gates["cool_fan_grace_s"] = {"gate": None, "def": 15.0, "lo": 0.0, "hi": 120.0, "band": [5, 30],
"off": "none", "value": g, "state": "ok"}
self.fc.state["settings"]["gates"] = gates
def _on_post(self, path, form):
if path != "/settings":
return None
self.fc.state["settings"].update(form)
self._describe()
return (200, self.fc.state["settings"])
def _engine(self, line):
self._describe()
cool = self.fc.state["cool"]
if line == "M9":
def end():
time.sleep(0.3)
cool["phase"] = "idle"
# the fan fault is the session's: it ends with it
cool.update(verdict="OK", fire_ok=True, hold=False, reason="")
for g in cool.get("fan_gates", {}).values():
g["state"] = "idle"
threading.Thread(target=end, daemon=True).start()
return
if line != "M8":
return
cool["phase"] = "run"
floors = {fan: self.setting(key, default) for fan, (key, default, _h) in self.FLOORS.items()}
off = sorted({self.GATE_OF[f] for f, v in floors.items() if v <= 0}) if self.reports_off else []
cool.update(verdict="OK", fire_ok=True, hold=False, resume_ok=True, reason="", gates_off=off,
fan_gates={f: {"reading": self.READINGS[f], "floor": floors[f],
"state": "off" if floors[f] <= 0 else "grace"} for f in floors})
self.fc.state["status"]["gates_off"] = off
grace = self.setting("cool_fan_grace_s", 15.0) * self.grace_scale
def judge():
time.sleep(grace)
if cool["phase"] != "run":
return
for f in floors:
if floors[f] > 0:
cool["fan_gates"][f]["state"] = "ok" if self.READINGS[f] >= floors[f] else "under"
time.sleep(0.3)
if cool["phase"] != "run" or not self.trips:
return
for f in floors:
if 0 < floors[f] > self.READINGS[f]:
cool["fan_gates"][f]["state"] = "TRIPPED"
cool.update(verdict="AIRFLOW", fire_ok=False, hold=True, resume_ok=False,
reason="AIRFLOW: %s %d under the %d floor for 3 s - hold, no resume this job"
% (f, self.READINGS[f], floors[f]))
break
threading.Thread(target=judge, daemon=True).start()
def run_test(self):
run = Run("test", "cooling.fan-gate-trips", "t")
ctx = Context(run, None, helpers.make_test("cooling.fan-gate-trips", []))
cooling.fan_gate_trips(ctx)
return run
def settings_posts(self):
return [f for p, f in self.fc.posts if p == "/settings"]
def test_trip_purge_off_and_restore_pass(self):
run = self.run_test()
ev = run.evidence
self.assertEqual(ev["exhaust_trip"]["cool"]["verdict"], "AIRFLOW")
self.assertEqual(ev["exhaust_trip"]["gate"]["state"], "TRIPPED")
self.assertEqual(ev["purge_trip"]["gate"]["state"], "TRIPPED")
self.assertEqual(ev["exhaust_off"]["cool"]["gates_off"], ["exhaust"])
self.assertTrue(all(g["state"] == "ok" for g in ev["restored"].values()))
posts = self.settings_posts()
self.assertEqual(posts[0], {"cool_tach_exhaust_min_rpm": "20000.0", "cool_fan_grace_s": "8"})
self.assertEqual(posts[-1], {"cool_tach_exhaust_min_rpm": "", "cool_purge_min_current": "",
"cool_fan_grace_s": ""})
self.assertEqual(self.grbl.commands.count("M8"), 4)
self.assertEqual(self.grbl.commands.count("M9"), 4)
def test_an_engine_that_does_not_trip_fails_and_restores(self):
self.trips = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("did not trip", str(cm.exception))
self.assertEqual(self.settings_posts()[-1], {"cool_tach_exhaust_min_rpm": "", "cool_purge_min_current": "",
"cool_fan_grace_s": ""})
self.assertEqual(self.fc.state["cool"]["verdict"], "OK")
def test_an_engine_that_hides_an_off_floor_fails(self):
self.reports_off = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("lacks exhaust", str(cm.exception))
self.assertEqual(self.fc.state["settings"]["cool_tach_exhaust_min_rpm"], "")
from forgetest.suite import cooling
class FlowVerdictLogTests(unittest.TestCase):
@@ -817,5 +59,6 @@ class FlowVerdictLogTests(unittest.TestCase):
self.write(self.VERDICT) # the rotation: a new, shorter file
self.assertEqual(cooling._log_since(self.path, off), self.VERDICT)
def test_a_missing_log_reads_as_nothing(self):
self.assertEqual(cooling._log_since(os.path.join(self.dir, "none.log"), 0), "")
if __name__ == "__main__":
unittest.main()