mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-27 16:51:12 -07:00
BRINGUP: cooling v2 - job-scoped heater, thermal cooldown, over-temp pause drilled
This commit is contained in:
+16
-2
@@ -239,8 +239,22 @@ hardware I/O — host testing).
|
|||||||
+4.6..5.7 within 20 s; fault = ΔT>4.5 °C for 20 s, live-verified:
|
+4.6..5.7 within 20 s; fault = ΔT>4.5 °C for 20 s, live-verified:
|
||||||
pump stopped → sender warning in 40 s → recovery re-arms).
|
pump stopped → sender warning in 40 s → recovery re-arms).
|
||||||
Absolute ceiling 33 °C (job-header CMrx; heater adds ~1.5 °C to
|
Absolute ceiling 33 °C (job-header CMrx; heater adds ~1.5 °C to
|
||||||
the loop). TEC control remains for the thermal part of the laser
|
the loop). **v2 (same day): heater job-scoped** (M8..M9 only — an
|
||||||
milestone; both warnings become hard fire gates there.
|
always-on heater eats headroom below the 31 °C start gate at
|
||||||
|
idle; flow faulting arms 30 s after heater-on), **two-phase
|
||||||
|
cooldown** (15 s smoke clear at run duty, then half-duty airflow
|
||||||
|
until the upstream temp is under the 31 °C resume gate or
|
||||||
|
`GFCOOL_COOLDOWN_MAX_S`), and **factory-style over-temp pause**
|
||||||
|
using the factory coolant windows (run ceiling 33 °C / resume
|
||||||
|
31 °C, env-adjustable: `GFCOOL_TEMP_MAX`/`GFCOOL_TEMP_RESUME`):
|
||||||
|
a CYCLE over the ceiling gets a feed hold + forced cooling
|
||||||
|
airflow + auto-resume on recovery; a JOG gets a jog-cancel
|
||||||
|
(grblHAL refuses HOLD from the jog state by design). Senders see
|
||||||
|
the Hold state and [MSG:Warning:…] lines. Drilled live with test
|
||||||
|
limits: jog canceled mid-move, cycle held and auto-resumed, fan
|
||||||
|
profiles restored on stand-down. TEC control remains for the
|
||||||
|
laser milestone; these warnings/holds become hard fire gates
|
||||||
|
there.
|
||||||
- **Interlock readback semantics cross-check: OPEN** (see
|
- **Interlock readback semantics cross-check: OPEN** (see
|
||||||
factory-laser-safety-readbacks notes).
|
factory-laser-safety-readbacks notes).
|
||||||
3. **Homing (design decided 2026-08-02)**: the factory machine has NO
|
3. **Homing (design decided 2026-08-02)**: the factory machine has NO
|
||||||
|
|||||||
Reference in New Issue