forgetest: cooling.intake-one-fan, and setup.check-airflow reads the intake fan count

forgectrl c274f19 adds cool_intake_fans: at 1, a machine built with one
intake fan, the second intake is published not fitted and never judged,
and the setup's airflow check writes the count it finds.

cooling.intake-one-fan, in a suite module of its own, proves both halves
on a machine with two intake fans with the setting alone. With
cool_intake_fans 1 and an 8 s grace, a session at the cut fan profile
must publish intake_2 as not fitted with no floor while it reads a real
speed, run OK, and judge intake_1 ok at the intake floor; with the intake
floor at its legal maximum it must trip AIRFLOW (hold, fire blocked) with
intake_1 TRIPPED and intake_2 still not fitted, and the fault must end
with the session; restored, every fan reads ok at its floor. It starts
only from a machine with both intakes judged, requires
cooling.fan-gate-trips, and puts the count, the intake floor and the
grace back as found on every exit path.

setup.check-airflow now reads the count from the result: 2 needs all
four fans at least 1000 rpm, 1 needs intake 2 reported {"fitted": false}
and the other three ok; either way the setting must read what the check
found, and the count is put back with the five floors.

Fingerprints: the new test has a module of its own, so no cooling test
moves; the setup.check-airflow edit is inside its function. Diffed across
the change: 127 -> 128 tests, one added, setup.check-airflow the only
one moved.

Proof: the touched host tests pass (test_cooling_intake_suite 4,
test_setup_dark 10, test_cooling_suite 25) and pyflakes is clean.
test_cooling_intake_suite replays the test against a scripted engine,
and two broken engines fail it with the settings put back: one that
ignores the setting, and one that takes intake 1 out with intake 2.
test_setup_dark's new AirflowCheckTests take a two-fan and a one-fan
result, and fail a count the setting does not match and a result with
no count. On the bench reference, image 20260928194539 (dev) with these
files and forgectrl c274f19 bind-mounted, cooling.fan-gate-trips,
cooling.intake-one-fan and setup.check-airflow pass with a clean
baseline before and after each (forgectrl's commit has the readings).
This commit is contained in:
ScottW514
2026-10-10 17:33:43 -04:00
parent 72907f311a
commit 16a8ae9ba3
5 changed files with 425 additions and 6 deletions
@@ -0,0 +1,176 @@
# Copyright 2026 514 LLC d/b/a OpenGlow
# Written by Scott Wiederhold
# https://community.openglow.org
# SPDX-License-Identifier: MIT
"""cooling.intake-one-fan replayed host-side under the real runner
Context against a scripted engine: the fake reads cool_intake_fans and
the floors at every M8 (the engine reloads at run start), publishes
intake_2 not fitted with no floor when one intake fan is set, holds every
fan in grace for the configured seconds, then judges the bench readings
against the floors. The negative engines are the two ways the change
could go wrong: the setting ignored (intake 2 still judged) and the
setting taking intake 1 out with it."""
import threading
import time
import unittest
import helpers
from forgetest.runner import Context, Failed, Run
from forgetest.suite import cooling, cooling_intake
from test_cooling_suite import FakeGrbl
class IntakeOneFanTests(unittest.TestCase):
READINGS = {"exhaust": 11640, "intake_1": 4157, "intake_2": 4158, "air_assist": 11050, "purge": 625}
FLOORS = {"exhaust": ("cool_tach_exhaust_min_rpm", 6400.0, 20000.0),
"intake_1": ("cool_tach_intake_min_rpm", 2290.0, 20000.0),
"intake_2": ("cool_tach_intake_min_rpm", 2290.0, 20000.0),
"air_assist": ("cool_tach_air_assist_min_rpm", 6000.0, 30000.0),
"purge": ("cool_purge_min_current", 300.0, 1023.0)}
GATE_OF = {"exhaust": "exhaust", "intake_1": "intake", "intake_2": "intake",
"air_assist": "air_assist", "purge": "purge"}
def setUp(self):
self.fc = helpers.FakeForgectrl().start()
self.grbl = FakeGrbl()
self.saved = (cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S, cooling_intake.INTAKE_TRIP_WAIT_S)
cooling.VERDICT_WAIT_S = 4
cooling.SESSION_END_WAIT_S = 3
cooling_intake.INTAKE_TRIP_WAIT_S = 4
self.fc.state["status"] = dict(self.fc.state["status"], gates_off=[])
self.fc.state["cool"] = {"phase": "idle", "verdict": "OK", "fire_ok": False, "hold": False,
"gates_off": [], "fan_gates": {}}
for key, _d, _h in self.FLOORS.values():
self.fc.state["settings"].setdefault(key, "")
self.fc.state["settings"].setdefault("cool_fan_grace_s", "")
self.fc.state["settings"].setdefault("cool_intake_fans", "")
self.honors_setting = True # the engine takes intake 2 out with one intake fan
self.drops_both = False # the engine takes intake 1 out with it
self.grace_scale = 0.1 # seconds of fake grace per configured second
self._describe()
self.grbl.on_command = self._engine
self.fc.on_post = self._on_post
def tearDown(self):
cooling.VERDICT_WAIT_S, cooling.SESSION_END_WAIT_S, cooling_intake.INTAKE_TRIP_WAIT_S = self.saved
self.grbl.close()
self.fc.stop()
def setting(self, key, default):
v = self.fc.state["settings"].get(key) or ""
return float(v) if v else default
def _describe(self):
gates = {}
for fan, (key, default, hi) in self.FLOORS.items():
v = self.setting(key, default)
gates[key] = {"gate": self.GATE_OF[fan], "def": default, "lo": 0.0, "hi": hi,
"band": [default * 0.9, default * 1.1], "off": "low", "value": v,
"state": "off" if v <= 0 else "ok"}
self.fc.state["settings"]["gates"] = gates
def _on_post(self, path, form):
if path != "/settings":
return None
self.fc.state["settings"].update(form)
self._describe()
return (200, self.fc.state["settings"])
def _engine(self, line):
self._describe()
cool = self.fc.state["cool"]
if line == "M9":
def end():
time.sleep(0.3)
cool["phase"] = "idle"
cool.update(verdict="OK", fire_ok=True, hold=False, reason="")
for g in cool.get("fan_gates", {}).values():
if g["state"] != "not fitted":
g["state"] = "idle"
threading.Thread(target=end, daemon=True).start()
return
if line != "M8":
return
cool["phase"] = "run"
one = self.fc.state["settings"].get("cool_intake_fans") == "1" and self.honors_setting
out = {"intake_2"} | ({"intake_1"} if self.drops_both else set()) if one else set()
floors = {fan: 0.0 if fan in out else self.setting(key, default)
for fan, (key, default, _h) in self.FLOORS.items()}
cool.update(verdict="OK", fire_ok=True, hold=False, resume_ok=True, reason="", gates_off=[],
fan_gates={f: {"reading": self.READINGS[f], "floor": floors[f],
"state": "not fitted" if f in out else "grace"} for f in floors})
grace = self.setting("cool_fan_grace_s", 15.0) * self.grace_scale
def judge():
time.sleep(grace)
if cool["phase"] != "run":
return
for f in floors:
if f not in out:
cool["fan_gates"][f]["state"] = "ok" if self.READINGS[f] >= floors[f] else "under"
time.sleep(0.3)
if cool["phase"] != "run":
return
for f in floors:
if f not in out and floors[f] > self.READINGS[f]:
cool["fan_gates"][f]["state"] = "TRIPPED"
if cool["verdict"] != "AIRFLOW":
cool.update(verdict="AIRFLOW", fire_ok=False, hold=True, resume_ok=False,
reason="AIRFLOW: %s %d under the %d floor for 3 s - hold, no resume this job"
% (f, self.READINGS[f], floors[f]))
threading.Thread(target=judge, daemon=True).start()
def run_test(self):
run = Run("test", "cooling.intake-one-fan", "t")
ctx = Context(run, None, helpers.make_test("cooling.intake-one-fan", []))
cooling_intake.intake_one_fan(ctx)
return run
def settings_posts(self):
return [f for p, f in self.fc.posts if p == "/settings"]
def restored(self):
return {"cool_intake_fans": "", "cool_tach_intake_min_rpm": "", "cool_fan_grace_s": ""}
def test_one_fan_then_intake_1_trip_then_restore_pass(self):
run = self.run_test()
ev = run.evidence
self.assertEqual(ev["one_fan"]["intake_2"]["state"], "not fitted")
self.assertEqual(ev["one_fan"]["intake_1"]["state"], "ok")
self.assertEqual(ev["intake_1_trip"]["intake_1"]["state"], "TRIPPED")
self.assertEqual(ev["intake_1_trip"]["intake_2"]["state"], "not fitted")
self.assertTrue(all(g["state"] == "ok" for g in ev["restored"].values()))
posts = self.settings_posts()
self.assertEqual(posts[0], {"cool_intake_fans": "1", "cool_fan_grace_s": "8"})
self.assertEqual(posts[1], {"cool_tach_intake_min_rpm": "20000.0"})
self.assertEqual(posts[-1], self.restored())
self.assertEqual(self.grbl.commands.count("M8"), 3)
self.assertEqual(self.grbl.commands.count("M9"), 3)
def test_an_engine_that_ignores_the_setting_fails_and_restores(self):
self.honors_setting = False
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("intake_2 is not published not fitted", str(cm.exception))
self.assertEqual(self.settings_posts()[-1], self.restored())
self.assertEqual(self.fc.state["cool"]["verdict"], "OK")
def test_an_engine_that_drops_intake_1_too_fails_and_restores(self):
self.drops_both = True
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("intake_1 is not judged ok at the intake floor", str(cm.exception))
self.assertEqual(self.settings_posts()[-1], self.restored())
def test_a_machine_already_at_one_intake_fan_is_refused_untouched(self):
self.fc.state["settings"]["cool_intake_fans"] = "1"
with self.assertRaises(Failed) as cm:
self.run_test()
self.assertIn("already 1", str(cm.exception))
self.assertEqual(self.settings_posts(), [])
self.assertEqual(self.grbl.commands.count("M8"), 0)
if __name__ == "__main__":
unittest.main()
+119
View File
@@ -137,5 +137,124 @@ class SensorsCheckTests(unittest.TestCase):
self.assertIn(("/wiz/sensors/abort", {}), [(p, f) for p, f in self.fake.posts])
class AirflowCheckTests(unittest.TestCase):
"""setup.check-airflow's judge against a scripted daemon: the check
writes its floors and the intake fans fitted, and the test reads the
fans the count says are there. A machine built with one intake fan
reports intake 2 not fitted; the bench reference has two."""
FLOORS = {"cool_tach_exhaust_min_rpm": "6400", "cool_tach_intake_min_rpm": "2290",
"cool_tach_air_assist_min_rpm": "6050", "cool_purge_min_current": "345",
"cool_fan_grace_s": "12"}
FAN = {"steady_rpm": 4150, "spinup_s": 6.8, "ok": True}
def result(self, intakes):
fans = {"exhaust": dict(self.FAN), "intake 1": dict(self.FAN), "intake 2": dict(self.FAN),
"air assist": dict(self.FAN)}
if intakes == 1:
fans["intake 2"] = {"fitted": False}
return {"fans": fans, "intake_fans": intakes, "purge_current_on": 628, "purge_current_off": 74,
"floors": dict(self.FLOORS)}
def setUp(self):
import tempfile
self.sysfs = tempfile.mkdtemp(prefix="forgetest-airflow-")
os.makedirs(os.path.join(self.sysfs, "head"))
with open(os.path.join(self.sysfs, "head", "purge_air"), "w") as f:
f.write("1\n")
self.saved_root = os.environ.get("GF_SYSFS_ROOT")
os.environ["GF_SYSFS_ROOT"] = self.sysfs + "/"
self.fake = helpers.FakeForgectrl().start()
self.fake.state["settings"].update({"cool_tach_intake_min_rpm": "2300"})
self.fake.state["cool"] = {"phase": "idle", "fan_gates": {"purge": {"reading": 628, "floor": 345}}}
self.dark = {"id": "", "running": False, "phase": "", "progress": 0, "elapsed_s": 0,
"log": [], "prompt": None, "result": None, "error": "",
"shots": {"lid": False, "head": False}}
self.versions = {}
self.polls = 0
self.wizard_result = self.result(2)
self.wizard_writes = None # what the check writes; None = what its result says
def on_get(path, q):
if path == "/wiz/dark":
if self.dark["running"]:
self.polls += 1
if self.polls >= 2:
r = self.wizard_result
s = self.fake.state["settings"]
s.update(r["floors"])
s["cool_intake_fans"] = self.wizard_writes or str(r["intake_fans"])
self.dark.update({"running": False, "progress": 100, "result": r})
self.versions["airflow"] = 1
return 200, dict(self.dark)
if path == "/wiz":
return 200, {"versions": dict(self.versions), "required": [], "completed": True}
return None
def on_post(path, form):
s = self.fake.state["settings"]
if path == "/wiz/airflow/start":
self.dark.update({"id": "airflow", "running": True, "phase": "fans to the run profile"})
return 200, {"started": True, "id": "airflow"}
if path == "/settings":
for k, v in form.items():
if v == "":
s.pop(k, None)
else:
s[k] = v
return 200, dict(s)
return None
self.fake.on_get = on_get
self.fake.on_post = on_post
def tearDown(self):
import shutil
self.fake.stop()
if self.saved_root is None:
os.environ.pop("GF_SYSFS_ROOT", None)
else:
os.environ["GF_SYSFS_ROOT"] = self.saved_root
shutil.rmtree(self.sysfs, ignore_errors=True)
def run_check(self):
t = catalog.load_suite()["setup.check-airflow"]
run = Run("test", t.id, t.title)
t.fn(Context(run, None, t))
return run
def assert_put_back(self):
s = self.fake.state["settings"]
self.assertEqual(s.get("cool_tach_intake_min_rpm"), "2300")
self.assertNotIn("cool_intake_fans", s)
self.assertNotIn("cool_tach_exhaust_min_rpm", s)
def test_two_intake_fans_pass_and_are_put_back(self):
self.run_check()
self.assert_put_back()
def test_one_intake_fan_passes_with_intake_2_not_fitted(self):
self.wizard_result = self.result(1)
self.run_check()
self.assert_put_back()
def test_one_intake_fan_with_the_setting_left_at_two_fails(self):
self.wizard_result = self.result(1)
self.wizard_writes = "2"
with self.assertRaises(Exception) as cm:
self.run_check()
self.assertIn("cool_intake_fans reads '2', the check found 1", str(cm.exception))
self.assert_put_back()
def test_a_result_without_the_count_fails(self):
r = self.result(2)
del r["intake_fans"]
self.wizard_result = r
self.wizard_writes = "2"
with self.assertRaises(Exception) as cm:
self.run_check()
self.assertIn("no intake fan count", str(cm.exception))
self.assert_put_back()
if __name__ == "__main__":