laser_lifecycle_test: the sessions the unit tests and the stream prove leave
Each case below repeated a rule another test in CI already proves, read assertion by assertion next to it in the 2026-10-13 test audit: - test_job_window: laser_arm_test.c case I (S changes, and now M5 then M3, inside the window never re-prompt; df7087b) and laser_stream_test session K (M2 closes the window, the next job re-arms). - test_hold_grace: test_resume_after_grace makes the same assertion. - test_verdict_blocks_arm, test_arm_waits_for_engine_ack, test_arm_proceeds_on_a_late_ack: laser_arm_test.c cases C, A2, A3 and cooling_test.c's arm-time gate. test_arm_waits_for_the_fans stays. - test_sender_change: laser_arm_test.c case H; the disarm on a client change is unconditional. - test_jog_does_not_extend_window: laser_arm_test.c case S10. - test_verdict_fail_tier_ends_job: laser_stream_test rule 25 and laser_arm_test.c case V2. - test_verdict_pause_resumes_without_press: laser_stream_test rule 24, which now counts one arm across the pause, and case V1. - test_sender_change_mid_job: merged into test_sender_change_holds_and_rearms, which takes its "held inside the move" position check. - test_sender_change_then_reset: the window is closed and the latch locked by the sender change itself (case H); a reset from Hold is not energy. The header's rules 1, 2, 5, 11, 12 and 14 keep their numbers and name the tests that now prove them. Proof: laser_lifecycle_test passes whole on a null-sink build of the grblHAL-glowforge working tree under Linux (17 sessions), and laser_stream_test with it. pyflakes is clean; no helper was left without a caller. Acceptance: none. The harness runs in grblHAL-glowforge's CI.
This commit is contained in:
@@ -10,16 +10,19 @@ hardware, no root; arming is automatic without the physical button)
|
||||
and drives jobs over TCP, asserting the window's state machine on the
|
||||
reported messages:
|
||||
|
||||
1. the first laser-on of a job arms exactly once, and the window
|
||||
persists across M5/M3 toggles within the job (no re-prompt)
|
||||
2. program end (M2) closes the window: the disarm lands promptly,
|
||||
and the next job arms afresh
|
||||
1. the first laser-on of a job arms exactly once; the window's
|
||||
persistence across S changes and M5/M3 toggles inside the job is
|
||||
laser_arm_test.c case I's
|
||||
2. program end (M2) closing the window, and the next job arming
|
||||
afresh: laser_stream_test session K
|
||||
3. a sender change closes the window: a reconnected client must
|
||||
re-arm - the displaced session's consent does not carry over
|
||||
4. the spindle-off grace counts down in HOLD, not only in Idle - a
|
||||
job abandoned in feed hold disarms after laser_disarm_s
|
||||
5. arming is refused while the cooling verdict blocks fire, and no
|
||||
armed message appears
|
||||
5. arming refused while the cooling verdict blocks fire, or before
|
||||
the engine acknowledges the session: laser_arm_test.c cases C, A2
|
||||
and A3, and cooling_test.c's arm-time gate; the wait for the fans
|
||||
is this harness's
|
||||
6. with a switch source present (GF_SWITCH_FILE), the arm blocks on the
|
||||
button: a press with the lid closed arms, and the lid or the
|
||||
interlock loop opening during the wait cancels the job (a clean
|
||||
@@ -44,17 +47,16 @@ reported messages:
|
||||
not to where it was paused (the core restarts a held cycle through
|
||||
Idle); a job abandoned in a hold and reset ends there, so the next
|
||||
job's start is captured afresh where it begins
|
||||
11. the cooling verdict's pause tier (OVERTEMP) holds the job under the
|
||||
open window without writing the latch (a lock sets the hardware
|
||||
button latch, which only a press clears); the clean verdict then
|
||||
resumes it with no new button press: no prompt, no second arm
|
||||
12. the verdict's fail tier (AIRFLOW) ends the job: disarmed, reset with
|
||||
ALARM:3, and a ~ under the clean verdict that follows resumes nothing
|
||||
11. the cooling verdict's pause tier holding the job under the open
|
||||
window without a latch write, and the clean verdict resuming it with
|
||||
no press and no second arm: laser_stream_test rule 24 and
|
||||
laser_arm_test.c case V1
|
||||
12. the verdict's fail tier ending the job (disarmed, ALARM:3, nothing
|
||||
resumed): laser_stream_test rule 25 and laser_arm_test.c case V2
|
||||
13. a sender change during a re-arm cancels it: the press that follows
|
||||
resumes nothing, the job stays held, and the new sender's own ~
|
||||
prompts afresh
|
||||
14. a jog does not hold the armed window open: with the spindle off the
|
||||
grace counts down through jogs, and the window closes on time
|
||||
14. a jog not holding the armed window open: laser_arm_test.c case S10
|
||||
15. a press counts only after the button has been seen up: a press that
|
||||
began before the wait is not consent (the harness's own presses
|
||||
follow a fresh prompt for the same reason)
|
||||
@@ -429,88 +431,10 @@ def test_laser_keys_reload():
|
||||
s.close()
|
||||
|
||||
|
||||
def test_job_window():
|
||||
"""Rules 1 + 2: arm once per job, persist across M5/M3, close at M2,
|
||||
fresh consent for the next job. The grace is set far beyond the test
|
||||
horizon so only the program-end close can produce the disarm."""
|
||||
s = Session("job-window", disarm_s=60)
|
||||
try:
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X1 F600", s.log)
|
||||
if not wait_for(s.log, ARMED, 5, s.sock):
|
||||
fail("[job-window] first laser-on did not arm")
|
||||
send_line(s.sock, "M5", s.log)
|
||||
send_line(s.sock, "M3 S200", s.log)
|
||||
send_line(s.sock, "G1 X0 F600", s.log)
|
||||
wait_idle(s.sock, s.log)
|
||||
if s.armed_count() != 1:
|
||||
fail("[job-window] M5/M3 inside one job re-prompted the arm "
|
||||
"(armed messages: %d)" % s.armed_count())
|
||||
send_line(s.sock, "M2", s.log)
|
||||
if not wait_for(s.log, DISARMED, 5, s.sock):
|
||||
fail("[job-window] program end (M2) did not close the armed window")
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X1 F600", s.log)
|
||||
if not wait_for(s.log, ARMED, 5, s.sock) or s.armed_count() != 2:
|
||||
fail("[job-window] next job after M2 did not arm afresh")
|
||||
wait_idle(s.sock, s.log)
|
||||
print("PASS [job-window]: armed once per job, M2 closed the window, "
|
||||
"next job re-armed")
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_sender_change_mid_job():
|
||||
"""Rule 3, the hard case: the sender changes while the job is still
|
||||
running with the spindle on. The window closes and the job is HELD
|
||||
where the cut stopped, so the next sender finds it in Hold rather than
|
||||
at the end of a dark pass. Its cycle start goes through the resume
|
||||
gate, which re-arms first: with no button on a host build that is
|
||||
immediate, and the job then runs to its end lit."""
|
||||
s = Session("sender-change-mid-job", disarm_s=60)
|
||||
try:
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X5 F60", s.log) # 5 s of motion
|
||||
if not wait_for(s.log, ARMED, 5, s.sock):
|
||||
fail("[sender-change-mid-job] first laser-on did not arm")
|
||||
time.sleep(1.0)
|
||||
s.sock.close() # mid-move, spindle on
|
||||
time.sleep(0.5)
|
||||
# The disarm and hold messages are written while no client is
|
||||
# connected, and output with no client is discarded, so the new
|
||||
# session cannot see them; the Hold state and the re-arm below are
|
||||
# the evidence.
|
||||
s.sock = s.connect()
|
||||
st = s.wait_state("Hold", 5)
|
||||
if st is None:
|
||||
fail("[sender-change-mid-job] the job was not held on the sender change "
|
||||
"(state %r)" % s.state())
|
||||
x_held = s.mpos_x()
|
||||
if x_held is None or not 0.5 < x_held < 4.5:
|
||||
fail("[sender-change-mid-job] held outside the move (MPos X %s)" % x_held)
|
||||
before = s.armed_count()
|
||||
s.sock.sendall(b"~") # the new sender resumes
|
||||
end = time.time() + 15
|
||||
while time.time() < end and s.armed_count() != before + 1:
|
||||
read_avail(s.sock, s.log, 0.2)
|
||||
if s.armed_count() != before + 1:
|
||||
fail("[sender-change-mid-job] the resume after a mid-job sender change did "
|
||||
"not re-arm")
|
||||
wait_idle(s.sock, s.log)
|
||||
x_end = s.mpos_x()
|
||||
if x_end is None or abs(x_end - 5.0) > 0.01:
|
||||
fail("[sender-change-mid-job] the resumed job did not finish the move "
|
||||
"(MPos X %s)" % x_end)
|
||||
send_line(s.sock, "M5", s.log)
|
||||
print("PASS [sender-change-mid-job]: the job held at X=%.3f on the sender change, "
|
||||
"re-armed on the resume and finished at X=%.3f" % (x_held, x_end))
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_sender_change_holds_and_rearms():
|
||||
"""Rule 3 on a machine with a button: the held job's resume from the
|
||||
new sender prompts for the press (collected from the poll, never
|
||||
"""Rule 3 on a machine with a button: a sender change mid-move, spindle
|
||||
on, holds the job where the cut stopped; the held job's resume from
|
||||
the new sender prompts for the press (collected from the poll, never
|
||||
inside the core's held state), and the press re-arms and resumes."""
|
||||
s = Session("sender-change-rearm", disarm_s=60, switches=SW_CLOSED)
|
||||
try:
|
||||
@@ -527,6 +451,9 @@ def test_sender_change_holds_and_rearms():
|
||||
s.sock = s.connect()
|
||||
if s.wait_state("Hold", 5) is None:
|
||||
fail("[sender-change-rearm] the job was not held on the sender change")
|
||||
x_held = s.mpos_x()
|
||||
if x_held is None or not 0.5 < x_held < 4.5:
|
||||
fail("[sender-change-rearm] held outside the move (MPos X %s)" % x_held)
|
||||
before = s.armed_count()
|
||||
s.sock.sendall(b"~")
|
||||
if not wait_for(s.log, RESUME_PROMPT, 5, s.sock):
|
||||
@@ -545,33 +472,8 @@ def test_sender_change_holds_and_rearms():
|
||||
fail("[sender-change-rearm] the resumed job did not finish the move "
|
||||
"(MPos X %s)" % x_end)
|
||||
send_line(s.sock, "M5", s.log)
|
||||
print("PASS [sender-change-rearm]: the held job prompted on ~, the press re-armed "
|
||||
"it, and it finished at X=%.3f" % x_end)
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_sender_change_then_reset():
|
||||
"""A new sender that does not want the held job resets it: a soft
|
||||
reset from the hold ends the job with the position kept and no alarm."""
|
||||
s = Session("sender-change-reset", disarm_s=60)
|
||||
try:
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X5 F60", s.log)
|
||||
if not wait_for(s.log, ARMED, 5, s.sock):
|
||||
fail("[sender-change-reset] first laser-on did not arm")
|
||||
time.sleep(1.0)
|
||||
s.sock.close()
|
||||
time.sleep(0.5)
|
||||
s.sock = s.connect()
|
||||
if s.wait_state("Hold", 5) is None:
|
||||
fail("[sender-change-reset] the job was not held on the sender change")
|
||||
s.sock.sendall(b"\x18")
|
||||
st = s.wait_state("Idle", 5)
|
||||
if st is None:
|
||||
fail("[sender-change-reset] a reset from the held job did not end in Idle "
|
||||
"(state %r)" % s.state())
|
||||
print("PASS [sender-change-reset]: a reset from the held job ends in Idle, no alarm")
|
||||
print("PASS [sender-change-rearm]: held at X=%.3f, the held job prompted on ~, the "
|
||||
"press re-armed it, and it finished at X=%.3f" % (x_held, x_end))
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
@@ -656,130 +558,6 @@ def test_rx_overrun_aborts():
|
||||
s.close()
|
||||
|
||||
|
||||
def test_sender_change():
|
||||
"""Rule 3: a reconnected sender must re-arm. The grace is set far
|
||||
beyond the test horizon so only the sender change can close the
|
||||
window; the first job ends in M5 and the next M4 is a fresh laser-on."""
|
||||
s = Session("sender-change", disarm_s=60)
|
||||
try:
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X1 F600", s.log)
|
||||
if not wait_for(s.log, ARMED, 5, s.sock):
|
||||
fail("[sender-change] first laser-on did not arm")
|
||||
send_line(s.sock, "M5", s.log)
|
||||
wait_idle(s.sock, s.log)
|
||||
s.sock.close()
|
||||
time.sleep(0.5)
|
||||
s.sock = s.connect()
|
||||
before = s.armed_count()
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X0 F600", s.log)
|
||||
end = time.time() + 5
|
||||
while time.time() < end and s.armed_count() != before + 1:
|
||||
read_avail(s.sock, s.log, 0.2)
|
||||
if s.armed_count() != before + 1:
|
||||
fail("[sender-change] the reconnected sender inherited the "
|
||||
"displaced session's armed window")
|
||||
wait_idle(s.sock, s.log)
|
||||
print("PASS [sender-change]: displaced consent did not survive; "
|
||||
"the new sender re-armed")
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_hold_grace():
|
||||
"""Rule 4: the disarm grace counts down in HOLD."""
|
||||
s = Session("hold-grace", disarm_s=2)
|
||||
try:
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X30 F60", s.log) # ~30 s move
|
||||
if not wait_for(s.log, ARMED, 5, s.sock):
|
||||
fail("[hold-grace] job did not arm")
|
||||
time.sleep(1.0)
|
||||
s.sock.sendall(b"!") # feed hold
|
||||
if not wait_for(s.log, DISARMED, 10, s.sock):
|
||||
fail("[hold-grace] a job abandoned in Hold stayed armed past "
|
||||
"the disarm grace")
|
||||
print("PASS [hold-grace]: the armed window closed while parked in Hold")
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_verdict_blocks_arm():
|
||||
"""Rule 5: a blocking cooling verdict refuses the arm."""
|
||||
s = Session("verdict-blocked", fire_ok=False)
|
||||
try:
|
||||
send_line(s.sock, "M4 S100", s.log, tolerate_error=True)
|
||||
send_line(s.sock, "G1 X1 F600", s.log, tolerate_error=True)
|
||||
if not wait_for(s.log, BLOCKED, 5, s.sock):
|
||||
fail("[verdict-blocked] no refusal message for a blocking verdict")
|
||||
if ARMED in "".join(s.log):
|
||||
fail("[verdict-blocked] armed despite a blocking cooling verdict")
|
||||
print("PASS [verdict-blocked]: arming refused while fire_ok=false")
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_arm_waits_for_engine_ack():
|
||||
"""Rule 5: the arm does not fire on a verdict computed before it.
|
||||
|
||||
The armed window is reported to the cooling engine when it opens,
|
||||
and the engine answers by applying the cut airflow and the flow
|
||||
interrogation for the job. The verdict standing on file until that
|
||||
answer arrives is the one computed for the idle session that
|
||||
preceded the arm, and at idle nothing is wrong, so it says fire is
|
||||
fine. Firing on it puts the beam on the work with the fans still at
|
||||
their idle duty - observed on the bench as a burn of a few
|
||||
millimeters before the engine's first tick took the job into a hold.
|
||||
|
||||
Here the engine never acknowledges: fire_ok stays true throughout,
|
||||
so the only thing that can refuse the job is the missing
|
||||
acknowledgment. The arm must be refused and no window may open."""
|
||||
s = Session("arm-ack", fire_ok=True, armed_ack=False)
|
||||
try:
|
||||
# The arm blocks in the acknowledgment wait, so the ok for these
|
||||
# lines only arrives once it gives up: send without waiting.
|
||||
s.send_raw("M4 S100")
|
||||
s.send_raw("G1 X1 F600")
|
||||
if not wait_for(s.log, BLOCKED, 15, s.sock):
|
||||
fail("[arm-ack] a job whose cooling engine never took it was not "
|
||||
"refused (the arm fired on the pre-arm verdict)")
|
||||
if ARMED in "".join(s.log):
|
||||
fail("[arm-ack] the armed window opened without the engine's "
|
||||
"acknowledgment")
|
||||
print("PASS [arm-ack]: the arm refused a verdict that predates it")
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_arm_proceeds_on_a_late_ack():
|
||||
"""Rule 5: the acknowledgment arriving late is the ordinary case.
|
||||
|
||||
The real engine answers on its next tick, so the arm has to observe
|
||||
a verdict refreshed under it and then go on to open the window. This
|
||||
is the case that proves the wait is a wait and not a refusal: the
|
||||
controller must keep polling the verdict file while it is blocked in
|
||||
the arm, or every job on the machine would fail here."""
|
||||
ack_s = 2.0
|
||||
s = Session("arm-ack-late", fire_ok=True, ack_after_s=ack_s)
|
||||
try:
|
||||
t0 = time.time()
|
||||
s.send_raw("M4 S100")
|
||||
s.send_raw("G1 X1 F600")
|
||||
if not wait_for(s.log, ARMED, 15, s.sock):
|
||||
fail("[arm-ack-late] the arm never completed once the engine took "
|
||||
"the job (the verdict is not refreshed inside the wait)")
|
||||
dt = time.time() - t0
|
||||
if dt < ack_s - 0.5:
|
||||
fail("[arm-ack-late] armed after %.1f s, before the engine took the "
|
||||
"job at %.1f s" % (dt, ack_s))
|
||||
if BLOCKED in "".join(s.log):
|
||||
fail("[arm-ack-late] a late acknowledgment was reported as a refusal")
|
||||
print("PASS [arm-ack-late]: the arm waited %.1f s for the engine, then armed" % dt)
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_arm_waits_for_the_fans():
|
||||
"""Rule 5: the acknowledgment budget follows the fan grace. The
|
||||
engine acknowledges once the fans are at their floors, seconds after
|
||||
@@ -1136,76 +914,6 @@ def test_lid_policy_hold():
|
||||
s.close()
|
||||
|
||||
|
||||
def test_verdict_pause_resumes_without_press():
|
||||
"""Rule 11: the pause tier holds under the open window without a
|
||||
latch write; the clean verdict resumes with no press. The window is
|
||||
proven still open by the absence of any prompt and of a second arm."""
|
||||
s = Session("verdict-pause", disarm_s=60, switches=SW_CLOSED)
|
||||
try:
|
||||
start_armed_move(s, "verdict-pause", gcode="G1 X30 F120") # 15 s of motion
|
||||
time.sleep(0.5)
|
||||
s.set_verdict("OVERTEMP", fire_ok=False, hold=True, resume_ok=False)
|
||||
if not s.wait_state("Hold", 5):
|
||||
fail("[verdict-pause] the pause tier did not hold the job (state %s)" % s.state())
|
||||
if not wait_for(s.log, "fire masked, job held", 3, s.sock):
|
||||
fail("[verdict-pause] the pause tier did not report the masked hold")
|
||||
if "latch locked" in "".join(s.log):
|
||||
fail("[verdict-pause] the pause tier wrote the latch")
|
||||
if DISARMED in "".join(s.log):
|
||||
fail("[verdict-pause] the pause tier closed the armed window")
|
||||
time.sleep(1.5)
|
||||
s.set_verdict("OK", fire_ok=True, hold=False, resume_ok=True)
|
||||
if not s.wait_state("Run", 5):
|
||||
fail("[verdict-pause] the clean verdict did not resume the job (state %s)" % s.state())
|
||||
if not wait_for(s.log, "resuming", 2, s.sock):
|
||||
fail("[verdict-pause] the resume was not reported")
|
||||
if RESUME_PROMPT in "".join(s.log) or s.count(PROMPT) != 1:
|
||||
fail("[verdict-pause] the resume asked for a button press")
|
||||
if s.armed_count() != 1:
|
||||
fail("[verdict-pause] the resume armed again (armed messages: %d)" % s.armed_count())
|
||||
if "ALARM" in "".join(s.log):
|
||||
fail("[verdict-pause] the pause tier raised an alarm")
|
||||
s.sock.sendall(b"\x18")
|
||||
print("PASS [verdict-pause]: OVERTEMP held under the open window with no latch write; "
|
||||
"the clean verdict resumed with no press")
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_verdict_fail_tier_ends_job():
|
||||
"""Rule 12: the fail tier disarms, resets the job with ALARM:3, and
|
||||
nothing resumes it."""
|
||||
s = Session("verdict-fail", disarm_s=60, switches=SW_CLOSED)
|
||||
try:
|
||||
start_armed_move(s, "verdict-fail", gcode="G1 X30 F120")
|
||||
time.sleep(0.5)
|
||||
s.set_verdict("AIRFLOW", fire_ok=False, hold=True, resume_ok=False)
|
||||
if not s.wait_state("Alarm", 5):
|
||||
fail("[verdict-fail] the fail tier did not end the job in Alarm (state %s)" % s.state())
|
||||
if not wait_for(s.log, DISARMED, 3, s.sock):
|
||||
fail("[verdict-fail] the fail tier did not close the armed window")
|
||||
text = "".join(s.log)
|
||||
if "ALARM:3" not in text:
|
||||
fail("[verdict-fail] no ALARM:3 on the fail tier")
|
||||
if "AIRFLOW" not in text:
|
||||
fail("[verdict-fail] the fail tier did not name the verdict")
|
||||
s.set_verdict("OK", fire_ok=True, hold=False, resume_ok=True)
|
||||
time.sleep(1.5)
|
||||
s.sock.sendall(b"~")
|
||||
read_avail(s.sock, s.log, 1.0)
|
||||
if not s.state().startswith("Alarm"):
|
||||
fail("[verdict-fail] a ~ after the fail tier resumed something (state %s)" % s.state())
|
||||
if "resuming" in "".join(s.log):
|
||||
fail("[verdict-fail] the client resumed after the fail tier")
|
||||
send_line(s.sock, "$X", s.log)
|
||||
if not s.wait_state("Idle", 3):
|
||||
fail("[verdict-fail] $X did not unlock the alarm")
|
||||
print("PASS [verdict-fail]: AIRFLOW disarmed, reset the job with ALARM:3, and nothing "
|
||||
"resumed it")
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def test_sender_change_during_rearm_cancels():
|
||||
"""Rule 13: a sender change while a re-arm waits for the press
|
||||
cancels the re-arm; the press resumes nothing and the job stays
|
||||
@@ -1257,46 +965,14 @@ def test_sender_change_during_rearm_cancels():
|
||||
s.close()
|
||||
|
||||
|
||||
def test_jog_does_not_extend_window():
|
||||
"""Rule 14: with the spindle off, jogs do not reset the disarm grace:
|
||||
the window closes on time through them."""
|
||||
s = Session("jog-grace", disarm_s=2)
|
||||
try:
|
||||
send_line(s.sock, "M4 S100", s.log)
|
||||
send_line(s.sock, "G1 X1 F600", s.log)
|
||||
if not wait_for(s.log, ARMED, 5, s.sock):
|
||||
fail("[jog-grace] job did not arm")
|
||||
send_line(s.sock, "M5", s.log)
|
||||
wait_idle(s.sock, s.log)
|
||||
t0 = time.time()
|
||||
while time.time() - t0 < 5.0 and DISARMED not in "".join(s.log):
|
||||
send_line(s.sock, "$J=G91X1F1200", s.log)
|
||||
read_avail(s.sock, s.log, 0.3)
|
||||
dt = time.time() - t0
|
||||
if DISARMED not in "".join(s.log):
|
||||
fail("[jog-grace] the window stayed open through %.1f s of jogging (grace 2 s)" % dt)
|
||||
wait_idle(s.sock, s.log)
|
||||
print("PASS [jog-grace]: the window closed after %.1f s of jogging with the spindle off" % dt)
|
||||
finally:
|
||||
s.close()
|
||||
|
||||
|
||||
def main():
|
||||
if not os.path.isfile(BIN):
|
||||
fail("controller binary not found at %s" % BIN)
|
||||
test_verdict_pause_resumes_without_press()
|
||||
test_verdict_fail_tier_ends_job()
|
||||
test_sender_change_during_rearm_cancels()
|
||||
test_jog_does_not_extend_window()
|
||||
test_job_window()
|
||||
test_status_files()
|
||||
test_laser_keys_reload()
|
||||
test_sender_change()
|
||||
test_sender_change_mid_job()
|
||||
test_sender_change_holds_and_rearms()
|
||||
test_sender_change_then_reset()
|
||||
test_rx_overrun_aborts()
|
||||
test_hold_grace()
|
||||
test_resume_after_grace()
|
||||
test_button_wait_arms()
|
||||
test_lid_open_in_wait()
|
||||
@@ -1304,9 +980,6 @@ def main():
|
||||
test_lid_cancels_and_returns()
|
||||
test_pause_then_lid_cancel_returns_to_the_job_start()
|
||||
test_lid_policy_hold()
|
||||
test_verdict_blocks_arm()
|
||||
test_arm_waits_for_engine_ack()
|
||||
test_arm_proceeds_on_a_late_ack()
|
||||
test_arm_waits_for_the_fans()
|
||||
test_sigterm_mid_job()
|
||||
print("PASS: the armed-window lifecycle holds")
|
||||
|
||||