bcf63db527
Run 2 is an SFT on the official instruct base, so it will refuse at near-stock rates by design; targeted DPO is where refusals get pruned on chosen axes. That was the trade accepted when the stock base was picked over a third-party abliteration. Surveys what is on disk against what the stage needs. Ready: the merged tune, the SFT adapter, GPU0 once the eval seat comes down, the whole non-loss half of the SFT harness, two unvetted Gutenberg preference sets, and the LitBench-RM judge. Missing, in order of pain: preference data for the refusal axes (nothing on disk targets it -- the Gutenberg sets are prose-quality), the axis list itself, and a DPO trainer (trl is not installed). The gating item is not technical: WHICH refusal axes are in scope and which are explicitly kept. Data generation, pair counts, the held-out split and the success probe are all functions of that list, so nobody should generate a pair before it is written down. Flags that the domain-compliance probe should measure run 2 BEFORE pruning, since the pre-number is the only baseline that will ever exist. Also records the operational trap: do the trl install AFTER a run finishes, never during one -- a resolution that upgrades transformers under a live process can break its save path.
docs/
Navigation map for the documentation tree. New session? Read
orientation.md first — it's the narrative overview
of the fleet, backup architecture, governing principles, and gotchas,
and it points at everything else.
Tree
docs/
├── orientation.md # start here — fleet overview + where-to-look guide
├── runbooks/ # ops runbooks (recovery, deployment phases)
│ ├── disaster-recovery.md
│ ├── nh3-prune-ritual.md
│ └── pbs-deployment.md
└── pfi/ # PFI-specific reference (services, models, VMs)
├── docker-stack.md
├── model-list.md
├── proxmox-vms.md
├── recommended-model-settings.md
├── vm-102-matrix-appservice.md
└── vm-102-matrix-synapse.md
What goes where
runbooks/— step-by-step ops procedures. Anything you'd reach for during an incident or while standing up new infrastructure. Examples: disaster recovery (blast-radius tiers + restoration steps), PBS deployment (9-phase rollout). New runbook → new file here.pfi/— PFI-specific reference material that's too narrow for the top-level CLAUDE.md but doesn't change incident response. AI model inventory, recommended inference settings, Matrix bridge config, Proxmox VM map. New stable reference → new file here.- Top-level (
docs/orientation.md,docs/README.md) — narrative guides about the workspace itself, not about specific infra.
Cross-references
- Fleet topology + servers table: top-level
CLAUDE.md. - Open work + recent milestones: top-level
STATUS.md. - Durable cross-session facts:
~/.claude/projects/-home-lkraven-development-eshpfi-management/memory/.
Conventions
- Markdown, GitHub-flavored. CommonMark renders fine in most viewers.
- File names are lowercase-kebab-case, descriptive. No dates in filenames — git history covers that.
- One topic per file. If a file grows past ~500 lines, look for a natural split before adding more.
- No checked-in binaries or checksums. Build/release artifacts belong
in a build pipeline or
tools/, notdocs/.