nh3-pve and esh-pve are the same Minisforum MS-01 (BIOS AHWSA.1.17). With a card in the x16 slot its root port takes bus 01 and every NIC moves down a bus (measured on esh-pve), so predictable names change (enp2s0f0np0 -> enp3s0f0np0 etc.) and vmbr0 would boot with no uplink. systemd .link files now pin all NICs by MAC, baked into every initramfs and synced to the ESP; udev confirms the files apply. The AMT-capable I226-LM (enp88s0) leaves vmbr0's bridge-ports in the file (next boot), so cabling it for AMT cannot loop the STP-less bridge. Also: documented the NanoKVM (https://10.100.250.171) as nh3-pve's console OOB and that AMT is not wired; nh3-dev's Beszel agent no longer binds NAS shares (it died on the last NH3 cold start); post-boot checklist in persistent-memory.
4.6 KiB
nh3-pve
Proxmox VE hypervisor for the NH3 site (nh3-vmhost.phasefinal.com).
Network
- LAN IP: 10.100.250.60
- FQDN:
nh3-vmhost.phasefinal.com - Web UI:
https://10.100.250.60:8006 - SSH:
root@nh3-pve(key auth)
Hardware
- CPU: 13th Gen Intel Core i9-13900H
- RAM: 62.5 GB
- Kernel:
6.8.12-11-pve(Proxmox 8.x) - Storage: mostly networked —
/mnt/pve/pfi-nh3-nas(42 TB) mounted from the Synology at10.100.50.50:/volume1/VMStorage; ~27 TB used
What it runs
Guests as of 2026-09-24 (qm list / pct list is the live truth). Expected state
after a power loss is the column that matters in a recovery: a guest listed as
stays off is not a casualty.
| ID | guest | kind | onboot | expected after power loss |
|---|---|---|---|---|
| 100 | nh3-docker (10.100.50.40) |
VM | 1 | up |
| 101 | nh3-extdev (10.100.50.42) |
VM | 1 | up |
| 102 | nh3-dev (10.100.10.50) |
VM | 1 | up |
| 104 | nh3-laser | VM | — | stays off — on-demand (Prime, 2026-09-24) |
| 105 | pbs-nh3 (10.100.50.90) |
VM | 1 | up (onboot added 2026-09-24; it had none and stayed down after the outage) |
| 108 | opnsense-lab | VM | 0 | stays off (lab) |
| 103 | nh3-wg | CT | 1 | up |
| 106 | nh3-headscale | CT | 1 | up |
| 107 | nh3-scale | CT | 1 | up (mesh subnet router + fleet egress proxy) |
Power-loss recovery (2026-09-24 outage). Every guest boots at once, and
nh3-nas is the slowest to serve NFS. NFS clients now mount nh3-nas shares on
first access (playbooks/nh3-nfs-automount.yaml, applied to nh3-docker and
nh3-dev), so a late NAS no longer leaves shares down. pbs-nh3's datastore line
uses bg (background retry) instead. qm guest exec 105 works (the guest agent is
on), which is the root path into pbs-nh3; infra-ops is not provisioned there.
pfi-gx10 (10.100.50.60) is bare metal on this site, not a guest here, and did
not power back on by itself.
Hardware identity, OOB, and the GPU-slot NIC-rename trap (2026-09-25)
- Box: Minisforum MS-01 ("Venus Series", BIOS
AHWSA.1.17): the same model and BIOS as esh-pve. i9-13900H, X710 2×SFP+, I226-V + I226-LM (vPro/AMT), one PCIe x16 slot (x8 electrical, low-profile, single-slot, slot power only). - Uplink: only
enp2s0f0np0(SFP+ 10G) has a cable. The bridge carries the I226-V's MAC…:96:0dbecause it is the first port listed. - AMT: NOT wired. The AMT-capable I226-LM (
enp88s0, MAC58:47:ca:76:96:0e) has no cable. The ME is present (/dev/mei0, "AMT SOL Redirection" 00:16.3), but MEBx provisioning status is unknown. To wire it: cable the LM port, then at boot press Ctrl+P → set the MEBx password, enable manageability, set network (static or DHCP), KVM on, User Opt-in = None, activate network access. MEBx can be driven remotely through the NanoKVM below. - Console OOB exists: a Sipeed NanoKVM is attached (USB
3346:1009on the host; web UIhttps://10.100.250.171, switch port 23, nh3-mgmt). It gives video and keyboard, so BIOS, MEBx and a host that booted without network are all reachable remotely. Power control through it is unverified (the MS-01 has no standard ATX front-panel header). ⚠ It captures the iGPU's HDMI, and RTX-class cards output mini-DP only, so keep the BIOS primary display on the iGPU after a GPU install. - ⚠ A GPU in the slot RENAMES every NIC. With a card present the slot's root
port 00:01.0 takes PCI bus 01 and everything behind it moves down a bus (measured
on esh-pve): X710 02→03, I226-V 57→58, I226-LM 58→59, Wi-Fi 59→5a. The names
would become
enp3s0f0np0,enp88s0,enp89s0,wlp90s0. vmbr0 would then boot with no uplink and take the whole NH3 site's VMs off the network. Pinned 2026-09-25 by MAC with/etc/systemd/network/10-pin-*.link, also baked into every initramfs and synced to the ESP (playbooks/nh3-pve-pin-nic-names.yaml, verified withudevadm test-builtin net_setup_link). If the host ever boots without network anyway: open the NanoKVM console, runip -br link, and compare names against/etc/network/interfaces(backup in/root/nic-pin-2026-09-25/). enp88s0(the AMT port) is no longer a vmbr0 bridge port (file edited 2026-09-25, effective next boot). STP is off, so bridging a second cabled uplink into the same L2 would loop the site LAN.
Refresh state
scripts/refresh-server-info.sh nh3-pve
Same Proxmox-inspect caveat as pfi-pve: snapshots capture host-level detail only. VM/LXC/storage enumeration needs the Proxmox tooling manually.
Placement rule
Hypervisor. New NH-site workloads land here as VMs.