Files
esh-pfi-infrastructure/docs
vh 317868dc7e feat(augaman): second, fixtures-only instance on fv-ml1 GPU 1; CPU vs GPU speed bench (v0.1.2 baseline)
Prime asked for augaman on fv-ml1's utility card, beside vllm-coder. Mirror
augaman-dev's f77164f compose, which parameterises the GPU reservation (GPU_ID,
default 0) and the Homepage card name (CARD_SUFFIX). esh-ml1's resolved config is
unchanged: same config hash, no recreate.

On fv-ml1: augaman:0.1.2 built on-box from the tag, GPU_ID=1, healthy on CUDA
at 1264 MiB, and pytest -m gpu tests/vision passes 3/3 on the Blackwell. It has
its own gallery and no gallery backup, so it is fixtures-only. The host's raw
restic copy of /var/lib/docker/volumes is not a consistent SQLite backup.

docs/pfi/augaman-speed-bench/ holds the harness (augaman-dev's recipe plus a
no-face control frame and a face-count check on every response), the raw rows
and the summary. Server-side, one face:
- esh-ml1 GPU 144 ms
- fv-ml1 GPU 75 ms
- fv-ml1 CPU on 6 cores 152 ms
- esh-ml1 CPU 888 ms
It agrees with augaman-dev's independent esh-ml1 measurement once each
harness's floor is subtracted. This is the before for v0.1.3's detector fix.
2026-09-27 00:28:20 -07:00
..

docs/

Navigation map for the documentation tree. New session? Read orientation.md first — it's the narrative overview of the fleet, backup architecture, governing principles, and gotchas, and it points at everything else.

Tree

docs/
├── orientation.md            # start here — fleet overview + where-to-look guide
├── runbooks/                 # ops runbooks (recovery, deployment phases)
│   ├── disaster-recovery.md
│   ├── nh3-prune-ritual.md
│   └── pbs-deployment.md
└── pfi/                      # PFI-specific reference (services, models, VMs)
    ├── docker-stack.md
    ├── model-list.md
    ├── proxmox-vms.md
    ├── recommended-model-settings.md
    ├── vm-102-matrix-appservice.md
    └── vm-102-matrix-synapse.md

What goes where

  • runbooks/ — step-by-step ops procedures. Anything you'd reach for during an incident or while standing up new infrastructure. Examples: disaster recovery (blast-radius tiers + restoration steps), PBS deployment (9-phase rollout). New runbook → new file here.
  • pfi/ — PFI-specific reference material that's too narrow for the top-level CLAUDE.md but doesn't change incident response. AI model inventory, recommended inference settings, Matrix bridge config, Proxmox VM map. New stable reference → new file here.
  • Top-level (docs/orientation.md, docs/README.md) — narrative guides about the workspace itself, not about specific infra.

Cross-references

  • Fleet topology + servers table: top-level CLAUDE.md.
  • Open work + recent milestones: top-level STATUS.md.
  • Durable cross-session facts: ~/.claude/projects/-home-lkraven-development-eshpfi-management/memory/.

Conventions

  • Markdown, GitHub-flavored. CommonMark renders fine in most viewers.
  • File names are lowercase-kebab-case, descriptive. No dates in filenames — git history covers that.
  • One topic per file. If a file grows past ~500 lines, look for a natural split before adding more.
  • No checked-in binaries or checksums. Build/release artifacts belong in a build pipeline or tools/, not docs/.