Prime asked for augaman on fv-ml1's utility card, beside vllm-coder. Mirror augaman-dev's f77164f compose, which parameterises the GPU reservation (GPU_ID, default 0) and the Homepage card name (CARD_SUFFIX). esh-ml1's resolved config is unchanged: same config hash, no recreate. On fv-ml1: augaman:0.1.2 built on-box from the tag, GPU_ID=1, healthy on CUDA at 1264 MiB, and pytest -m gpu tests/vision passes 3/3 on the Blackwell. It has its own gallery and no gallery backup, so it is fixtures-only. The host's raw restic copy of /var/lib/docker/volumes is not a consistent SQLite backup. docs/pfi/augaman-speed-bench/ holds the harness (augaman-dev's recipe plus a no-face control frame and a face-count check on every response), the raw rows and the summary. Server-side, one face: - esh-ml1 GPU 144 ms - fv-ml1 GPU 75 ms - fv-ml1 CPU on 6 cores 152 ms - esh-ml1 CPU 888 ms It agrees with augaman-dev's independent esh-ml1 measurement once each harness's floor is subtracted. This is the before for v0.1.3's detector fix.
docs/
Navigation map for the documentation tree. New session? Read
orientation.md first — it's the narrative overview
of the fleet, backup architecture, governing principles, and gotchas,
and it points at everything else.
Tree
docs/
├── orientation.md # start here — fleet overview + where-to-look guide
├── runbooks/ # ops runbooks (recovery, deployment phases)
│ ├── disaster-recovery.md
│ ├── nh3-prune-ritual.md
│ └── pbs-deployment.md
└── pfi/ # PFI-specific reference (services, models, VMs)
├── docker-stack.md
├── model-list.md
├── proxmox-vms.md
├── recommended-model-settings.md
├── vm-102-matrix-appservice.md
└── vm-102-matrix-synapse.md
What goes where
runbooks/— step-by-step ops procedures. Anything you'd reach for during an incident or while standing up new infrastructure. Examples: disaster recovery (blast-radius tiers + restoration steps), PBS deployment (9-phase rollout). New runbook → new file here.pfi/— PFI-specific reference material that's too narrow for the top-level CLAUDE.md but doesn't change incident response. AI model inventory, recommended inference settings, Matrix bridge config, Proxmox VM map. New stable reference → new file here.- Top-level (
docs/orientation.md,docs/README.md) — narrative guides about the workspace itself, not about specific infra.
Cross-references
- Fleet topology + servers table: top-level
CLAUDE.md. - Open work + recent milestones: top-level
STATUS.md. - Durable cross-session facts:
~/.claude/projects/-home-lkraven-development-eshpfi-management/memory/.
Conventions
- Markdown, GitHub-flavored. CommonMark renders fine in most viewers.
- File names are lowercase-kebab-case, descriptive. No dates in filenames — git history covers that.
- One topic per file. If a file grows past ~500 lines, look for a natural split before adding more.
- No checked-in binaries or checksums. Build/release artifacts belong
in a build pipeline or
tools/, notdocs/.