Bundles the inventory expansion since 2026-04-22:

- New host dirs (READMEs + ssh-target where dir name doesn't resolve):
    ana-nas, ana-wg, esh-vm-db, nh3-nas, pbs-ana, pbs-nh3.
- New PFI VM snapshots (registered + key-installed 2026-04-23):
    ana-filebot, pfi-ana-webhost, pfi-postgres, pfi-pteradactyl,
    pfi-tacticalrmm, sf-ana-container, sfsrv-ana (system + proxmox).
- servers/irv-ml1: ONBOARDING.md (the first-time setup notes from when
  the host was brought into the fleet) + ssh-target (10.100.79.3 over
  the WG tunnel — name doesn't DNS-resolve from this workstation).
- servers/{ana-ml2,pfi-pve,sf-r630}/README.md: updates to capture BMC
  IPs, the iDRAC vs OS hostname distinction (sf-r630 hardware =
  sfsrv-ana OS), and the ana-ml2 Supermicro BMC (10.250.250.50,
  distinct from the Dell R750xs iDRAC).
- configs/homepage/docker.yaml: irv-ml1-docker provider added so
  homepage auto-discovers irv-ml1's stacks over the WG tunnel.
- docs/orientation.md: narrative fleet overview written for fresh
  Claude sessions — sites, backup architecture, governing principles,
  gotchas, where-to-look guide. Pointed at from CLAUDE.md.
2026-04-24 21:56:46 -07:00
..

pbs-nh3

Proxmox Backup Server — DR mirror. VM on nh3-pve with an NFS-mounted datastore on the NH3 Synology. Pulls nightly from pbs-ana (the primary) at 06:00.

Network

  • LAN IP: 10.100.50.90
  • FQDN: pbs-nh3.phasefinal.com
  • PBS web UI: https://10.100.50.90:8007/
  • SSH: ssh pbs-nh3 (config alias → lkraven@10.100.50.90). Root ops via sudo from lkraven.
  • Homepage card: PBS-NH3 in Infra - NH3 group.

Hardware (VM)

  • Hypervisor: nh3-pve
  • vCPU: 4 (QEMU)
  • RAM: 7.8 GB
  • Root disk: /dev/sda1 31 GB ext4 — OS only (2 GB used)
  • Datastore: NFS from nh3-nas at /mnt/pbs-datastore10.100.50.50:/volume1/pbs. Volume size 42 TB; 27 TB used (64%).

NFS details (the Synology ACL gotcha)

Synology's /volume1/pbs share was initially created with "Advanced Permissions" which imposes a syno_acl that denies writes to non-admin UIDs (even the backup uid PBS runs as). Fix was to flatten the share to pure POSIX mode 777 so the mount becomes "Linux mode" (synoacltool -get confirms). no_root_squash + no_all_squash also set on the NFS export.

Mount uses NFSv3 (same pattern as pbs-ana, for consistency more than necessity — Synology's Btrfs doesn't have the ZFS-case-insensitivity issue):

10.100.50.50:/volume1/pbs /mnt/pbs-datastore nfs \
  defaults,_netdev,bg,hard,timeo=600,retrans=2,vers=3 0 0

Full history: docs/runbooks/pbs-deployment.md Phase 5.3.

What runs here

  • proxmox-backup-proxy — HTTPS API + web UI (port 8007)
  • proxmox-backup — backend service
  • Scheduled verify job: weekly Sunday 12:00 (after nightly sync completes), ignore-verified=true, outdated-after=30 days
  • Scheduled sync from pbs-ana: daily at 06:00 UTC

Remote config

  • Remote name: pbs-ana
  • Remote host: 10.250.50.90:8007
  • Auth: root@pam!fleet-vzdump token (same token as clients use on the primary — shared here for simplicity; could be split to a sync-only read-only token)
  • Cert fingerprint: in password manager under "pbs-ana fingerprint"

Namespaces

Namespaces are auto-replicated from pbs-ana via the sync job — you do NOT need to pre-create them on the mirror. Expected namespaces after first sync: same 5 as pbs-ana (pfi-pve, nh3-pve, esh-pve, esh-pve-nas, sfsrv-ana).

Dependencies / blast radius

  • Hard dependency on nh3-nas (Synology). Datastore goes dead if the Synology crashes; sync fails, verify fails, restore ops fail. But: ANA primary keeps operating fine, so the fleet's backup SLA is preserved — only DR redundancy is temporarily lost.
  • Sync source: pbs-ana going offline means no new snapshots pull here, but existing ones remain restorable. Sync resumes automatically once pbs-ana recovers.

DR failover (hypothetical)

If pbs-ana is permanently lost and we needed to restore fleet VMs from pbs-nh3:

  1. Re-point each PVE host's pbs-ana storage entry at pbs-nh3 (pve-datacenter.cfg → change server to 10.100.50.90)
  2. Fingerprint + token still work (same token)
  3. Cross-WAN restore is slower than local but functional

Documented as future work — not tested. Run a trial restore of a small CT periodically to validate.

Refresh

scripts/refresh-server-info.sh pbs-nh3

Snapshot at system-details.txt. Full deployment history: docs/runbooks/pbs-deployment.md.