ops(pfi-pve): upgraded to PVE 9.2.21 / kernel 7.0.14-20; reboot test + post-check recorded; pre-reboot checks corrected for PVE 9
This commit is contained in:
@@ -16,7 +16,11 @@ Proxmox VE hypervisor for the Anaheim colo (`pve.phasefinal.com`). Hosts every V
|
||||
- **Chassis:** Dell PowerEdge R750xs (2U rackmount)
|
||||
- **CPU:** Intel Xeon Silver 4310 @ 2.10 GHz
|
||||
- **RAM:** 188 GB
|
||||
- **Kernel:** `6.8.12-8-pve` (Proxmox 8.x)
|
||||
- **PVE / kernel:** 9.2.21 / `7.0.14-20-pve` since 2026-10-04 (upgraded from 8.3.5; `docs/runbooks/pfi-pve-pve9-upgrade-plan.md`)
|
||||
- **Boot:** UEFI → `\EFI\proxmox\grubx64.efi` on the BOSS card; `grub-efi-amd64` (was wrongly `grub-pc` until 2026-10-04). NIC names pinned by MAC (`/etc/systemd/network/10-pin-*.link`). Mgmt IP is DHCP on `vmbr0.250` (FortiGate lease)
|
||||
- **iDRAC9:** Enterprise licence (virtual console), fw 6.10.30.00; creds `secret get pfi-pve/idrac-infra-ops` (user `infra-ops`)
|
||||
- ⚠ **PSU1 has no input power** (repeatedly since 2026-04-23, latest 2026-09-11); running on PSU2 alone
|
||||
- ⚠ **Rebooting this host takes all of Anaheim off the fleet for ~4 min** (CT 114 ana-scale is the only NH3/ESH↔ANA path) **and the LiteLLM gateway off for ~20 min** (boot storm). Out-of-band way in: FortiGate WAN SSH `infra-ops@38.120.12.42` (see the upgrade plan § Break-glass)
|
||||
- **Storage:** local `pve-root` at 65G (49% used) + `pve` LVM pool for VM disks
|
||||
|
||||