Auto-summarize: ATLAS/Machining/Miltronics/Milltronics - General Setup.md
This commit is contained in:
@@ -1,2 +1,16 @@
|
|||||||
|
---
|
||||||
|
created: '2026-04-05T05:56:57+00:00'
|
||||||
|
id: bbe23a03-9b4d-42b0-8fd8-3af921b3a022
|
||||||
|
links: []
|
||||||
|
modified: '2026-04-05T05:56:57+00:00'
|
||||||
|
summary: 'Here''s a concise summary:
|
||||||
|
|
||||||
|
|
||||||
|
Mount the part in the chuck, then manually position to the face and set the G54
|
||||||
|
coordinate system offset.'
|
||||||
|
tags: []
|
||||||
|
title: Milltronics - General Setup
|
||||||
|
---
|
||||||
|
|
||||||
1. Chuck up part
|
1. Chuck up part
|
||||||
2. Jog to face and set G54 Offset
|
2. Jog to face and set G54 Offset
|
||||||
Reference in New Issue