mirror of
https://github.com/jokob-sk/NetAlertX.git
synced 2025-12-07 09:36:05 -08:00
wf work
This commit is contained in:
@@ -4,20 +4,21 @@
|
||||
> To backup 99% of your configuration backup at least the `/app/config` folder. Please read the whole page (or at least "Scenario 2: Corrupted database") for details.
|
||||
> Note that database definitions might change over time. The safest way is to restore your older backups into the **same version** of the app they were taken from and then gradually upgarde between releases to the latest version.
|
||||
|
||||
There are 3 artifacts that can be used to backup the application:
|
||||
There are 4 artifacts that can be used to backup the application:
|
||||
|
||||
| File | Description | Limitations |
|
||||
|-----------------------|-------------------------------|-------------------------------|
|
||||
| `/db/app.db` | Database file(s) | The database file might be in an uncommitted state or corrupted |
|
||||
| `/config/app.conf` | Configuration file | Can be overridden with the [`APP_CONF_OVERRIDE` env variable](https://github.com/jokob-sk/NetAlertX/tree/main/dockerfiles#docker-environment-variables). |
|
||||
| `/config/devices.csv` | CSV file containing device information | Doesn't contain historical data |
|
||||
| `/config/workflows.json` | A JSON file containing your workflows | N/A |
|
||||
|
||||
|
||||
## Backup strategies
|
||||
|
||||
The safest approach to backups is to backup everything, by taking regular file system backups (I use [Kopia](https://github.com/kopia/kopia)).
|
||||
The safest approach to backups is to backup everything, by taking regular file system backups of the `/db` and `/config` folders (I use [Kopia](https://github.com/kopia/kopia)).
|
||||
|
||||
Arguably, the most time is spent setting up the device list, so if only one file is kept I'd recommend to have a latest backup of the `devices_<timestamp>.csv` or `devices.csv` file, followed by the `app.conf` file. You can also download `app.conf` and `devices.csv` file in the Maintenance section:
|
||||
Arguably, the most time is spent setting up the device list, so if only one file is kept I'd recommend to have a latest backup of the `devices_<timestamp>.csv` or `devices.csv` file, followed by the `app.conf` and `workflows.json` files. You can also download `app.conf` and `devices.csv` file in the Maintenance section:
|
||||
|
||||

|
||||
|
||||
@@ -29,6 +30,7 @@ End-result: Full restore
|
||||
|
||||
- `/app/db/app.db` (uncorrupted)
|
||||
- `/app/config/app.conf`
|
||||
- `/app/config/workflows.json`
|
||||
|
||||
#### 📥 Recovery:
|
||||
|
||||
@@ -43,12 +45,13 @@ End-result: Partial restore (historical data and some plugin data will be missin
|
||||
|
||||
- `/app/config/app.conf`
|
||||
- `/app/config/devices_<timestamp>.csv` or `/app/config/devices.csv`
|
||||
- `/app/config/workflows.json`
|
||||
|
||||
#### 📥 Recovery:
|
||||
|
||||
Even with a corrupted database you can recover what I would argue is 99% of the configuration.
|
||||
|
||||
- upload the `app.conf` file into the mounted `/app/config/` folder as described in the [Setup documentation](https://github.com/jokob-sk/NetAlertX/blob/main/dockerfiles/README.md#docker-paths).
|
||||
- upload the `app.conf` and `workflows.json` files into the mounted `/app/config/` folder as described in the [Setup documentation](https://github.com/jokob-sk/NetAlertX/blob/main/dockerfiles/README.md#docker-paths).
|
||||
- rename the `devices_<timestamp>.csv` to `devices.csv` and place it in the `/app/config` folder
|
||||
- Restore the `devices.csv` backup via the [Maintenance section](./DEVICES_BULK_EDITING.md)
|
||||
|
||||
|
||||
@@ -17,8 +17,8 @@ There are 4 ways how to influence notifications:
|
||||
|
||||
There are 4 settings on the device for influencing notifications. You can:
|
||||
|
||||
1. **Alert Events** - Enables alerts of connections, disconnections, IP changes.
|
||||
2. **Alert Down** - Alerts when a device goes down. This setting overrides a disabled **Alert Events** setting, so you will get a notification of a device going down even if you don't have **Alert Events** ticked.
|
||||
1. **Alert Events** - Enables alerts of connections, disconnections, IP changes (down and down reconnected notifications are still sent even if this is disabled).
|
||||
2. **Alert Down** - Alerts when a device goes down. This setting overrides a disabled **Alert Events** setting, so you will get a notification of a device going down even if you don't have **Alert Events** ticked. Disabling this will disable down and down reconnected notifications on the device.
|
||||
3. **Skip repeated notifications**, if for example you know there is a temporary issue and want to pause the same notification for this device for a given time.
|
||||
|
||||
## Plugin settings 🔌
|
||||
@@ -38,7 +38,7 @@ Click the **Read more in the docs.** Link at the top of each plugin to get more
|
||||
|
||||
In Notification Processing settings, you can specify blanket rules. These allow you to specify exceptions to the Plugin and Device settings and will override those.
|
||||
|
||||
1. Notify on (`NTFPRCS_INCLUDED_SECTIONS`) allows you to specify which events trigger notifications. Usual setups will have `new_devices`, `down_devices`, and possibly `down_reconnected` set. Including `plugin` (dependenton the Plugin `<plugin>_WATCH` and `<plugin>_REPORT_ON` settings) and `events` (dependent on the on-device **Alert Events** setting) might be too noisy for most setups. More info in the [NTFPRCS plugin](/front/plugins/notification_processing/README.md)
|
||||
1. Notify on (`NTFPRCS_INCLUDED_SECTIONS`) allows you to specify which events trigger notifications. Usual setups will have `new_devices`, `down_devices`, and possibly `down_reconnected` set. Including `plugin` (dependenton the Plugin `<plugin>_WATCH` and `<plugin>_REPORT_ON` settings) and `events` (dependent on the on-device **Alert Events** setting) might be too noisy for most setups. More info in the [NTFPRCS plugin](/front/plugins/notification_processing/README.md) on what events these selections include.
|
||||
2. Alert down after (`NTFPRCS_alert_down_time`) is useful if you want to wait for some time before the system sends out a down notification for a device. This is related to the on-device **Alert down** setting and only devices with this checked will trigger a down notification.
|
||||
3. A filter to allow you to set device-specific exceptions to New devices being added to the app.
|
||||
4. A filter to allow you to set device-specific exceptions to generated Events.
|
||||
|
||||
@@ -56,7 +56,7 @@ Below you can find a couple of configuration examples.
|
||||
|
||||
### Trigger:
|
||||
- **Object Type**: `Devices`
|
||||
- **Event Type**: `insert`
|
||||
- **Event Type**: `create`
|
||||
|
||||
### Conditions:
|
||||
- **Logic**: `AND`
|
||||
|
||||
Reference in New Issue